CoChat

Miniaturized Reveal LINQ insertable cardiac monitoring system: First-in-human experience

Open access
Pürerfellner, Helmut, Sanders, Prashanthan, Pokushalov, Evgeny, Di Bacco, Marco, Bergemann, Tracy, Dekker, Lukas R.C. · 2015 · Heart Rhythm
Cited by 96

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The Reveal LINQ is a miniaturized insertable cardiac monitor (ICM) with wireless telemetry for remote monitoring of patients with suspected arrhythmias. OBJECTIVE: The primary objective of this study was to evaluate the functionality of the Reveal LINQ system by measuring R-wave sensing and data transmission. METHODS: The Reveal LINQ Usability Study was a nonrandomized, prospective, multicenter trial. The study enrolled 30 patients with any indication for an ICM. Data were collected at baseline, implantation, and 1-month follow-up visits and through daily wireless transmissions. RESULTS: Thirty patients were enrolled and had a Reveal LINQ device implanted. The mean age was 55 ± 15 years. All patients had successful implantation of the ICM in one of the recommended locations. Ease of implantation procedure was rated as easy or very easy for 90% of implantations. R-wave amplitudes were 0.584 ± 0.325 mV at implantation and 0.596 ± 0.336 mV at 1 month (P = .8). Automatic transmissions were successful 79.5% (69.5%-86.9%) of the time. Transmission failures that caused a delay in data transfer occurred because of incomplete data reception or patients being out of range in 45% and 42% of instances, respectively. For all patients, transmission failures were followed by successful automated or manual transmission of information on a subsequent day. The devices stored 217 arrhythmic episodes during 30 days of follow-up, identified as atrial fibrillation (n = 111), asystole (n = 95), bradycardia (n = 4), fast ventricular tachycardia (n = 1), and ventricular tachycardia ( n = 6). No serious procedure- or system-related adverse events occurred during the 1-month follow-up period. CONCLUSION: The miniaturized Reveal LINQ ICM supports arrhythmia detection and monitoring, achieving adequate sensing performance without safety issues. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01965899.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2015.02.030

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 96

Metadata

Authors
Pürerfellner, H., Sanders, P., Pokushalov, E., Di Bacco, M., Bergemann, T., & Dekker, L. R. C.
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2015-06
Volume
12
Issue
6
Pages
1113-1119
ISSN
1547-5271 (ISSN-L)
OpenAlex
W2092025629
Cited by
96
References
7
FWCI
9.15
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.