The DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index.
Assessing the accuracy of an automated atrial fibrillation detection algorithm using smartphone technology: The iREAD Study
Abstract
Background The Kardia Mobile Cardiac Monitor (KMCM) detects atrial fibrillation (AF) via a handheld cardiac rhythm recorder and AF detection algorithm. The algorithm operates within predefined parameters to provide a "normal" or "possible atrial fibrillation detected" interpretation; outside of these parameters, an "unclassified" rhythm is reported. The system has been increasingly used, but its performance has not been independently tested.Objective The objective of this study was to evaluate whether the KMCM system can accurately detect AF.Methods A single-center, adjudicator-blinded case series of 52 consecutive patients with AF admitted for antiarrhythmic drug initiation were enrolled. Serial 12-lead electrocardiograms (ECGs) and nearly simultaneously acquired KMCM recordings were obtained.Results There were 225 nearly simultaneously acquired KMCM and ECG recordings across 52 enrolled patients (mean age 68 years; 67% male). After exclusion of unclassified recordings, the KMCM automated algorithm interpretation had 96.6% sensitivity and 94.1% specificity for AF detection as compared with physician-interpreted ECGs, with a κ coefficient of 0.89. Physician-interpreted KMCM recordings had 100% sensitivity and 89.2% specificity for AF detection as compared with physician-interpreted ECGs, with a κ coefficient of 0.85. Sixty-two recordings (27.6%) were unclassified by the KMCM algorithm. In these instances, physician interpretation of KMCM recordings had 100% sensitivity and 79.5% specificity for AF detection as compared with 12-lead ECG interpretation, with a κ coefficient of 0.71.Conclusion The KMCM system provides sensitive and specific AF detection relative to 12-lead ECGs when an automated interpretation is provided. Direct physician review of KMCM recordings can enhance diagnostic yield, especially for unclassified recordings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the automatic diagnostic algorithm has excellent sensitivity (96.6%) and specificity (94%) for correctly interpreting AF versus normal sinus rhythm [15].”
From Multi-centre Randomised Controlled Trial of a Smartphone-based Event Recorder Alongside Standard Care Versus Standard Care for Patients Presenting to the Emergency Department with Palpitations and Pre-syncope: The IPED (Investigation of Palpitations in the ED) study (2019) · cites this paper as [15]
Citations
Cites
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H. G., Cigarroa, J. E., Cleveland, J. C., CONTI, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,145
Heart Disease and Stroke Statistics—2015 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., de Ferranti, S., Després, J.-P., Fullerton, H. J., Howard, V. J., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000152 · Cited by 5,797
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Calkins, H. G., Hindricks, G., Cappato, R., Kim, Y., Saad, E., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, A. J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,794
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Colilla, S., Crow, A., Petkun, W., Singer, D. E., Simon, T. A., & Liu, X. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.05.063 · Cited by 1,323
Wearable Devices as Facilitators, Not Drivers, of Health Behavior Change
Patel, M. S., Asch, D. A., & Volpp, K. G. (2015) · JAMA · doi:10.1001/jama.2014.14781 · Cited by 808
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Lowres, N., Neubeck, L., Salkeld, G., Krass, I., McLachlan, A. J., Redfern, J., Bennett, A. A., Briffa, T., Bauman, A., Martinez, C., et al. (2014) · Thrombosis and Haemostasis · doi:10.1160/th14-03-0231 · Cited by 458
Lau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326
Flagged first, then by citations
1 of the 14 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Items 101–153 of 153
A Smartphone App for Real-time Heart Rate Computation from Streaming ECG/EKG data
Utsha, U. T., & Morshed, B. I. (2023) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit57321.2023.10187337 · Cited by 6
“It has demonstrated effectiveness in clinical studies for detecting atrial fibrillation (AF), with a sensitivity of 96.6% and a specificity of 94.1% [6].”
BackgroundInfluentialDaniëls, F., Ramdjan, T. T. T. K., Mánfai, B., Adiyaman, A., Smit, J. J. J., Delnoy, P. P. H. M., & Elvan, A. (2023) · Netherlands Heart Journal · doi:10.1007/s12471-023-01828-6 · Cited by 6
Ambulatory electrocardiography: indications and devices
Sampson, M. G. (2019) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2019.14.3.114 · Cited by 6
Adeleke, Y., Matthew, D., Porter, B., Woodcock, T. M., Yap, J., Hashmy, S., Mathew, A., Grant, R., Kaba, A., Unger-Graeber, B., et al. (2019) · Open Heart · doi:10.1136/openhrt-2019-001086 · Cited by 6
Turnbull, S., Garikapati, K., Bennett, R. G., Campbell, T. G., Kotake, Y., Silva, K. D., Mahajan, R., Wong, M. S., Kazi, S., Marschner, S. L., et al. (2024) · Heart Lung and Circulation · doi:10.1016/j.hlc.2024.05.008 · Cited by 5
Cullen, J., Reed, M. J., Muir, A., Murphy, R., Pollard, V., Zangana, G. A. S., Krupej, S., Askham, S., Holdsworth, P., & Davies, L. (2021) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000000859 · Cited by 4
“AliveCor/Kardia is FDA-cleared and the most clinically validated ambulatory ECG event recorder available worldwide [5-11].”
BackgroundArtificial intelligence in cardiac electrophysiology
Somani, S. S., Narayan, S. M., & Rogers, A. J. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-15688-5.00021-8 · Cited by 4
A Database of Simultaneously Recorded ECG Signals With and Without EMG Noise
Atanasoski, V. A., Petrovic, J. S., Popović‐Maneski, L., Miletić, M., Babić, M., Nikolić, A., Panescu, D., & Ivanović, M. D. (2023) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2023.3330295 · Cited by 4
“Hence, the EMG noise must be eliminated by signal processing, which is particularly true for the measurements by handheld ECG devices, which imply the engagement of fingers [2], [3].”
BackgroundSluyter, J., Scragg, R. K. R., Ofanoa, M., & Stewart, R. (2021) · Scientific Reports · doi:10.1038/s41598-021-97475-1 · Cited by 4
Hashim, U. N., Salahuddin, L. B., Ikram, R. R. R., Rabaah, U., Choon, N. H., & Naim, M. H. (2021) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2021.0120120 · Cited by 4
“%) for correctly interpreting atrial fibrillation versus physician-interpreted ECGs [15].”
BackgroundInfluentialSmartphone-based ECG devices: Beyond atrial fibrillation screening
Wegner, F. K., & Eckardt, L. (2021) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2021.09.017 · Cited by 4
Weidlich, S., Mannhart, D., Serban, T., Krisai, P., Knecht, S., de Lavallaz, J. D. F., Müller, T., Schaer, B. A., Osswald, S., Kühne, M., et al. (2023) · Swiss Medical Weekly · doi:10.57187/smw.2023.40096 · Cited by 3
“Since previous studies mainly used only one smart device like the Apple Watch [5, 6] or the KardiaMobile [2, 3, 24–27] a direct comparison between different smart devices regarding the quality and readability of the SL-ECGs and their impact on the diagnostic value was not undertaken.”
BackgroundMethodIkeda, T., Ashihara, T., Iwasaki, Y., Ono, M., Kagiyama, N., Kimura, T., KUSANO, K. F., Kohno, R., Saku, K., Sasano, T., et al. (2025) · Journal of Arrhythmia · doi:10.1002/joa3.70059 · Cited by 3
Inconclusive Single-Lead ECGs From Smart-Devices
Isenegger, C., Mannhart, D., Weidlich, S., Brügger, J., Serban, T., Jordan, F., Krisai, P., Knecht, S., Schaerli, N., Subin, B., et al. (2025) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2025.04.027 · Cited by 4
Abnormal heart rate detection through real-time heart monitoring application
Hashim, U. N., Salahuddin, L. B., Hashim, U. R., Naim, M. H., Ikram, R. R. R., & Rahim, F. A. (2023) · Bulletin of Electrical Engineering and Informatics · doi:10.11591/beei.v12i4.4933 · Cited by 3
Zaprutko, T., Zaprutko, J., Sprawka, J., Pogodzińska, M., Michalak, M., Paczkowska, A., Kus, K., Nowakowska, E., & Baszko, A. (2021) · Cardiology Journal · doi:10.5603/cj.a2021.0083 · Cited by 3
Use of Smartphones and Wearables for Arrhythmia Monitoring
Sanders, D. J., Wasserlauf, J., & PASSMAN, R. S. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.004 · Cited by 3
Technological advances within digital medicine
Altibi, A. M. A., Alaref, S. J., & Khosravi, P. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820273-9.00001-4 · Cited by 2
Williamson, T. M., Rouleau, C. R., Wilton, S. B., Valdarchi, A. B., Moran, C., Patel, S. N., Lutes, L. D., Aggarwal, S., Arena, R. A., & Campbell, T. S. (2024) · Trials · doi:10.1186/s13063-024-08527-6 · Cited by 2
Digital health solutions in the screening of subclinical atrial fibrillation
König, S., Bollmann, A., & Hindricks, G. (2021) · Herz · doi:10.1007/s00059-021-05041-2 · Cited by 2
Vo, J. D. V., & Gorbach, A. M. (2018) · Interactive Journal of Medical Research · doi:10.2196/10336 · Cited by 2
“For example, patients can undergo remote cardiac monitoring using either wearable devices that send data to medical personnel or devices that could contain automated detection algorithms themselves [13,14].”
BackgroundApps every cardiologist should know about
Bennett, J. B., & Simpson, R. F. G. (2019) · Heart · doi:10.1136/heartjnl-2019-314716 · Cited by 2
Mansel, C. O., Sarnataro, R., & Liu, P. J. (2021) · British Journal of Healthcare Management · doi:10.12968/bjhc.2020.0064 · Cited by 1
Lee, J., Kim, T., Park, J., Joung, B., & Choi, E. (2021) · Korean Journal of Medicine · doi:10.3904/kjm.2021.96.2.76 · Cited by 1
A Deep Belief Network Model for Automatic Atrial Fibrillation Detection
Suresh, P., & Reka, S. S. (2023) · IETE Journal of Research · doi:10.1080/03772063.2023.2167739 · Cited by 1
Ikeda, T., Ashihara, T., Iwasaki, Y., Ono, M., Kagiyama, N., Kimura, T., KUSANO, K. F., Kohno, R., Saku, K., Sasano, T., et al. (2024) · Japanese Journal of Electrocardiology · doi:10.5105/jse.44.275 · Cited by 1
An Analytical Review on Data Privacy and Anonymity in “Internet of Things (IoT) Enabled Services”
Arya, A., & Jha, S. (2021) · International Conference on Advances in Computing, Communication Control and Networking (ICAC3N) · doi:10.1109/icac3n53548.2021.9725770 · Cited by 1
Development of a prototype for a mobile application to monitor hypertension from ECG data
Alsalami, O. M. (2023) · AIP Advances · doi:10.1063/5.0156019 · Cited by 1
Data and signals for the assessment of the cardiovascular system
Castells, F., Cervigón, R., & Millet, J. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-818950-4.00009-4 · Cited by 1
Innovative Technologies to Detect Atrial Fibrillation: “Wolf in Sheep’s Clothing?”
Bewick, D. J. (2019) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2019.04.010 · Cited by 1
Lee, J., Kim, T., Park, J., Joung, B., & Choi, E. (2021) · Korean Journal of Medicine · doi:10.3904/kjm.2021.96.3.252
New methods of detecting atrial fibrillation
Kotalczyk, A., Mazurek, M., & Jędrzejczyk‐Patej, E. (2020) · In a good rythm · doi:10.5604/01.3001.0014.4641
Artificial Intelligence in Medicine (AIM) for Cardiac Arrest
Makimoto, H. (2021) · Springer eBooks · doi:10.1007/978-3-030-58080-3_175-1
Enplegu, interés eta diruari buruzko teoria orokorra
Keynes, J. M. (1998) · Dialnet (Universidad de la Rioja)
(2021) · Revista Uruguaya de Cardiología · doi:10.29277/cardio.36.1.13
Artificial Intelligence in Medicine (AIM) for Cardiac Arrest
Makimoto, H. (2022) · Springer eBooks · doi:10.1007/978-3-030-64573-1_175
Telecardiología. De la prevención primaria a la secundaria
Carrillo-Alemán, L., Roy, I., Brocal, M. H., & Salinas, G. L. A. (2022) · REC CardioClinics · doi:10.1016/j.rccl.2022.06.005
Clinical applications of machine learning in heart failure
Li, X., Lee, S., Bazoukis, G., Tse, G., & Liu, T. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-819872-8.00017-3
Interpretation of electrocardiograms
(2023) · Pharmaceutical journal/The pharmaceutical journal · doi:10.1211/pj.2023.1.176371
Contemporary wearable and handheld technology for the diagnosis of cardiac arrhythmias in Singapore
Chia, P., Tan, K. W. K., Ng, S., & Foo, D. C. G. (2023) · Singapore Medical Journal · doi:10.4103/singaporemedj.smj-2023-048
“[27] The REHEARSE‑AF study showed the feasibility of using the KardiaMobile ® heart monitor in AF screening for at‑risk patients above 65 years of age over 12 months, with the potential to prevent ischaemic strokes.”
Kumar, S., Turnbull, S., Garikapati, K., Bennett, R. G., Campbell, T. G., Kotake, Y., Silva, K. D., Mahajan, R., Marschner, S. L., & Chow, C. K. (2023) · doi:10.22541/au.169581253.32737151/v1
Fedorin, I. V., & Синчук, В. (2023) · Наука і техніка сьогодні · doi:10.52058/2786-6025-2023-12(26)-834-849
Can eHealth programs for cardiac arrhythmias be scaled-up by using the KardiaMobile algorithm?
Slaats, B. M. I., Blok, S., Somsen, G. A., Tulevski, I. I., Knops, R. E., van den Born, B. H., & Winter, M. M. (2023) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2023.11.004
What Does Atrial Fibrillation Mean in Patients With Cardiac Implantable Electronic Devices?
Uhm, J. (2023) · Korean Circulation Journal · doi:10.4070/kcj.2023.0302
Behandlung von Vorhofflimmern in der Hausarztpraxis
Bleckwenn, M. (2024) · Allgemeinmedizin up2date · doi:10.1055/a-2016-0065
Patient Driven EKG Device Performance in Adults with Fontan Palliation
Laubham, M., Dodeja, A. K., Kumthekar, R. N., Shay, V., D'Emilio, N., Conroy, S., Mah, M. L., Alvarado, C., & Kamp, A. N. (2024) · Pediatric Cardiology · doi:10.1007/s00246-024-03614-6
“%) in this study was higher compared to other studies with non-CHD patients [5, 8, 13, 26, 27, 29].”
Rhythm-Ready: Harnessing Smart Devices to Detect and Manage Arrhythmias
Hsieh, P. N., & Singh, J. P. (2024) · Current Cardiology Reports · doi:10.1007/s11886-024-02135-1
“The KardiaMobile, which pairs with a smartphone to generate a single lead ECG, demonstrates sensitivity and specificity of 96.6% and 94.1% for AF detection compared with physician-interpreted ECGs (κ coefficient 0.89) [22].”
InfluentialSingle-Lead Mobile ECGs in Patients With Cardiovascular Disease
Steinberg, B. A. (2025) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2025.05.026
Ndisi, K. A., Paulo, D. G., Khanbhai, K., Mutagaywa, R., & Chin, J. H. (2026) · Heart Rhythm O2 · doi:10.1016/j.hroo.2026.06.014
“35 –37 Despite having a significant proportion of asymptomatic patients (38.6”
InfluentialDzikowicz, D. J., Aktaş, M. K., Horn, R., MacKecknie, B. D., Cutter, K., Mykins, B., Cenname, K., McNitt, S. A., Couderc, J.-P. Y., Strawderman, R. L., et al. (2026) · JACC Advances · doi:10.1016/j.jacadv.2026.103102
От первого электрокардиографа до смарт-технологий для диагностики аритмий у детей: обзор литературы
Томчик, Н. В., & Парамонова, Н. С. (2026) · Кардиология в Беларуси · doi:10.34883/pi.2026.18.4.009
Fenske, R., Rossa, D., Butter, C., Muehlensiepen, F., Nübel, J., Meretz, D., Ritter, O., Spethmann, S., Mantke, R., Zerbaum, M., et al. (2026) · JMIR Cardio · doi:10.2196/92799
“These findings differ from diagnostic validation studies conducted under controlled conditions but should not be interpreted as formal estimates of sensitivity or specificity because a universal reference-standard ECG was not applied [10,17,18].”
Metadata
- Authors
- William, A. D., Kanbour, M., Callahan, T., Bhargava, M., Varma, N., Rickard, J., Saliba, W., Wolski, K., Hussein, A., Lindsay, B. D., Wazni, O. M., & Tarakji, K. G.
- Affiliations
- Cleveland Clinic (US)
- Marshall University (US)
- Corresponding author
- Tarakji, Khaldoun G.
- ORCID
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 15
- Issue
- 10
- Pages
- 1561-1565
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2888509599
- Cited by
- 154
- References
- 14
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 10 · 2023: 32 · 2022: 19 · 2021: 30 · 2020: 25 · 2019: 23 · 2018: 2
- FWCI
- 15.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Heart Rhythm (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- atrial fibrillation, diagnostic accuracy, sensitivity and specificity, 12-lead ECG
- MeSH terms
- Smartphone, Adult, Aged, Aged, 80 and over, Algorithms, Atrial Fibrillation, Electrocardiography, Female, Heart Conduction System, Humans, Male, Middle Aged, Predictive Value of Tests, Signal Processing, Computer-Assisted, Telemetry, Reproducibility of Results, Single-Blind Method, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review