Brief training increases nurses' comfort using tele-ultrasound: A feasibility study
Abstract
Background Nurses and other non-physician providers have demonstrated proficiency at obtaining images in the tele-ultrasound system. However, use of this skill requires comfort with the procedure and willingness to incorporate it into practice.Objectives To assess 1) level of comfort of non-physician providers performing tele-ultrasound before and after brief training and 2) feasibility of implementing an educational programme that improves level of comfort.Methods Feasibility study including a brief training session followed by hands-on tele-ultrasound. The pilot cohort performed tele-ultrasound on a healthy volunteer. The clinical cohort performed tele-ultrasound on criticalli ill patients with shock or respiratory failure. Remote intensivists provided real-time guidance via tele-medicine technology. Each participant completed a survey assessing training experience and level of comfort before and after training.Results Sixteen non-physician providers participated. All participants agreed that the training session prepared them for image acquisition and that the training experience was positive. The number of participants comfortable with ultrasound improved significantly (before vs. after training: 5/16 [31%] vs. 16/16 [100%], mean Likert score 2.7 vs. 4.8, p = 0.001).Conclusions After brief training, participants could comfortably perform tele-ultrasound and were more willing to incorporate it into tele-ICU-directed care. Results support conducting a larger-scale trial of tele-US to assess clinical utility.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Based on research not included in this systematic review, synchronous RTMUS can be successfully performed with <60 min of training.
“Based on research not included in this systematic review, synchronous RTMUS can be successfully performed with <60 min of training (20, 21, 45, 46).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [46]
Cites
Analyzing and Interpreting Data From Likert-Type Scales
Sullivan, G. M., & Artino, A. R. (2013) · Journal of Graduate Medical Education · doi:10.4300/jgme-5-4-18 · Cited by 3,044 · see citing works
Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · CHEST Journal · doi:10.1378/chest.07-2800 · Cited by 2,058 · see citing works
BLUE-Protocol and FALLS-Protocol
Lichtenstein, D. A. (2015) · CHEST Journal · doi:10.1378/chest.14-1313 · Cited by 695 · see citing works
Breitkreutz, R., Walcher, F., & Seeger, F. H. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260626.23848.fc · Cited by 417 · see citing works
Brewster, L., Mountain, G. A., Wessels, B. A., Kelly, C. M., & Hawley, M. (2013) · Journal of Advanced Nursing · doi:10.1111/jan.12196 · Cited by 281 · see citing works
Bedside Ultrasound in Resuscitation and the Rapid Ultrasound in Shock Protocol
Seif, D., Perera, P., Mailhot, T., Riley, D. C., & Mandavia, D. P. (2012) · Critical Care Research and Practice · doi:10.1155/2012/503254 · Cited by 211 · see citing works
FAST at MACH 20: Clinical Ultrasound Aboard the International Space Station
Sargsyan, A. E., Hamilton, D. R., Jones, J. A., Melton, S. L., Whitson, P. A., Kirkpatrick, A. W., Martin, D. S., & Dulchavsky, S. A. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000145083.47032.78 · Cited by 197 · see citing works
Linking the Practice Environment to Nurses' Job Satisfaction Through Nurse‐Physician Communication
Manojlovich, M. (2005) · Journal of Nursing Scholarship · doi:10.1111/j.1547-5069.2005.00063.x · Cited by 192 · see citing works
Successful implementation of new technologies in nursing care: a questionnaire survey of nurse-users
de Veer, A. J. E., Fleuren, M. A. H., Bekkema, N., & Francke, A. L. (2011) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-11-67 · Cited by 180 · see citing works
Taylor, J., Coates, E., Brewster, L., Mountain, G., Wessels, B., & Hawley, M. S. (2015) · Journal of Advanced Nursing · doi:10.1111/jan.12480 · Cited by 164 · see citing works
Lilly, C. M., Zubrow, M. T., Kempner, K. M., Reynolds, H. N., Subramanian, S., Eriksson, E. A., Jenkins, C. L., Rincon, T., Kohl, B., Groves, R. H., et al. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000539 · Cited by 161 · see citing works
Self-citationProfessional autonomy and job satisfaction: survey of critical care nurses in mainland Greece
Iliopoulou, K., & While, A. (2010) · Journal of Advanced Nursing · doi:10.1111/j.1365-2648.2010.05424.x · Cited by 136 · see citing works
Brogi, E., Bignami, E. G., Sidoti, A., Shawar, M., Gargani, L., Vetrugno, L., Volpicelli, G., & Forfori, F. (2017) · Cardiovascular Ultrasound · doi:10.1186/s12947-017-0113-8 · Cited by 135 · see citing works
Boniface, K. S., Shokoohi, H., Smith, E. R., & Scantlebury, K. (2010) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2009.12.001 · Cited by 105 · see citing works
Ultrasound guided vascular access: efficacy and safety
Kumar, A., & Chuan, A. (2009) · Best practice & research. Clinical anaesthesiology · doi:10.1016/j.bpa.2009.02.006 · Cited by 81 · see citing works
Teleultrasound: Historical Perspective and Clinical Application
Ferreira, A. C., O’Mahony, E., Oliani, A. H., Júnior, E. A., & Costa, F. D. S. (2015) · International Journal of Telemedicine and Applications · doi:10.1155/2015/306259 · Cited by 74 · see citing works
Watson, S. (1994) · Journal of Advanced Nursing · doi:10.1046/j.1365-2648.1994.20020351.x · Cited by 69 · see citing works
Robertson, T. E., Levine, A. R., Verceles, A. C., Buchner, J. A., Lantry, J. H., Papali, A., Zubrow, M. T., Colas, L. N., Augustin, M. E., & McCurdy, M. T. (2017) · Journal of Critical Care · doi:10.1016/j.jcrc.2017.03.028 · Cited by 65 · see citing works
Self-citationMcBeth, P. B., Crawford, I., Tiruta, C., Xiao, Z. J., Zhu, G. Q., Shuster, M., Sewell, L., Panebianco, N. L., Lautner, D., Nicolaou, S., et al. (2013) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2013.0034 · Cited by 56 · see citing works
Tele-intensivists can instruct non-physicians to acquire high-quality ultrasound images
Levine, A. R., McCurdy, M. T., Zubrow, M. T., Papali, A., Mallemat, H. A., & Verceles, A. C. (2015) · Journal of Critical Care · doi:10.1016/j.jcrc.2015.05.030 · Cited by 55 · see citing works
Self-citationICU Telemedicine Comanagement Methods and Length of Stay
Hawkins, H. A., Lilly, C. M., Kaster, D. A., Groves, R. H., & Khurana, H. (2016) · CHEST · doi:10.1016/j.chest.2016.03.030 · Cited by 49 · see citing works
Zieleskiewicz, L., Cornesse, A., Hammad, E., Haddam, M., Brun, C., Vigne, C., Meyssignac, B., Remacle, A., Chaumoître, K., Antonini, F., et al. (2015) · Anaesthesia Critical Care & Pain Medicine · doi:10.1016/j.accpm.2015.01.002 · Cited by 48 · see citing works
Biegler, N., McBeth, P. B., Tiruta, C., Hamilton, D. R., Xiao, Z. J., Crawford, I., Tevez-Molina, M. C., Miletic, N., Ball, C. G., Pian, L., et al. (2013) · The Ultrasound Journal · doi:10.1186/2036-7902-5-5 · Cited by 45 · see citing works
An integrated approach for prescribing fewer chest x-rays in the ICU
Ioos, V., Galbois, A., Chalumeau-Lemoine, L., Guidet, B., Maury, É., & Hejblum, G. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-4 · Cited by 37 · see citing works
Olivieri, P. P., Verceles, A. C., Hurley, J. M., Zubrow, M. T., Jeudy, J. J., & McCurdy, M. T. (2018) · Journal of Intensive Care Medicine · doi:10.1177/0885066618777187 · Cited by 35 · see citing works
Self-citationUltrasound images transmitted via FaceTime are non-inferior to images on the ultrasound machine
Levine, A. R., Buchner, J. A., Verceles, A. C., Zubrow, M. T., Mallemat, H. A., Papali, A., & McCurdy, M. T. (2016) · Journal of Critical Care · doi:10.1016/j.jcrc.2016.02.019 · Cited by 34 · see citing works
Self-citationTele-Medicine and Point-of-Care Ultrasound
Levine, A. R., Robertson, T., Papali, A. C., Verceles, A. C., & McCurdy, M. T. (2016) · CHEST Journal · doi:10.1016/j.chest.2016.03.052 · Cited by 6 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Tele-Ultrasound in Resource-Limited Settings: A Systematic Review
Britton, N., Miller, M. A., Safadi, S., Siegel, A., Levine, A. R., & McCurdy, M. T. (2019) · Frontiers in Public Health · doi:10.3389/fpubh.2019.00244 · Cited by 166 · see citing works
Self-citationHayden, E. M., Davis, C. B., Clark, S., Joshi, A. U., Krupinski, E. A., Naik, N., Ward, M. J., Zachrison, K. S., Olsen, E., Chang, B., et al. (2021) · Academic Emergency Medicine · doi:10.1111/acem.14330 · Cited by 48 · see citing works
Point-of-Care Teleultrasound: A Systematic Review
Salerno, A., Tupchong, K., Verceles, A. C., & McCurdy, M. T. (2020) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2019.0177 · Cited by 42 · see citing works
Self-citationUltrasound in Telemedicine: A Brief Overview
Recker, F., Höhne, E., Damjanović, D., & Schäfer, V. S. (2022) · Applied Sciences · doi:10.3390/app12030958 · Cited by 40 · see citing works
Real-Time Remote Tele-Mentored Echocardiography: A Systematic Review
Salerno, A., Kuhn, D. M., Sibai, R. H. E., Levine, A. R., & McCurdy, M. T. (2020) · Medicina · doi:10.3390/medicina56120668 · Cited by 21 · see citing works
Self-citationShi, R., & Rosario, J. (2023) · Prehospital and Disaster Medicine · doi:10.1017/s1049023x23006234 · Cited by 14 · see citing works
The State of Point‐of‐Care Teleultrasound Use for Educational Purposes
Lipsitz, M. C., Levin, L., Sharma, V. K., Herrala, J., Rimawi, A., Bernier, D., Kimberly, H. H., Thomson, A. L., Soucy, Z. P., & Henwood, P. C. (2021) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15885 · Cited by 14 · see citing works
Sultan, L. R., Haertter, A., Al‐Hasani, M., Demiris, G., Cary, T. W., Tung‐Chen, Y., & Sehgal, C. M. (2023) · AI · doi:10.3390/ai4040044 · Cited by 12 · see citing works
Telementored ultrasonography: a narrative review
Duarte, M. L., dos Santos, L. R., Iared, W., & Peccin, M. S. (2022) · Sao Paulo Medical Journal · doi:10.1590/1516-3180.2020.0607.r2.15092021 · Cited by 9 · see citing works
The Role of Telehealth in Ultrasound Training for Remote Learners: A Systematic Review
Bui, C., Parange, N., Bezak, E., & Bidner, A. (2023) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2023.0396 · Cited by 7 · see citing works
Pillong, L., Bozzato, A., Hecker, D., Bozzato, V., Schick, B., & Kulas, P. (2022) · Diagnostics · doi:10.3390/diagnostics12051239 · Cited by 6 · see citing works
Yang, L., Lei, L., Zhang, S., Zhang, X., & Xu, M. (2025) · Nursing in Critical Care · doi:10.1111/nicc.70170 · Cited by 5 · see citing works
Kim, M., Son, M. H., Moon, S., Cha, W. C., Jo, I. J., & Yoon, H. J. (2024) · JMIR Serious Games · doi:10.2196/63448 · Cited by 4 · see citing works
Eke, O. F., Umoga, K., Morone, C. C., Shokoohi, H., Liteplo, A. S., & Haberer, J. E. (2024) · Internal and Emergency Medicine · doi:10.1007/s11739-024-03809-y · Cited by 4 · see citing works
Using point-of-care ultrasound in nursing
Geer, B. (2021) · Nursing · doi:10.1097/01.nurse.0000743052.88928.dc · Cited by 3 · see citing works
Conway, H., Evley, R., Yusuff, H. O., Wong, R., & Lau, G. T. E. (2025) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2025.07.019 · Cited by 2 · see citing works
Murugesu, S., Barcroft, J. F., Novak, A., Elhag, B., Saso, S., & Bourne, T. (2025) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.70029 · Cited by 1 · see citing works
Telehealth in the intensive care unit: Current insights and future directions
Xyrichis, A., & Iliopoulou, K. (2023) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2023.103412
Kim, M., Son, M. H., Moon, S., Cha, W. C., Jo, I. J., & Yoon, H. J. (2024) · doi:10.2196/preprints.63448
- Authors
- Douglas, T. M., Levine, A. R., Olivieri, P. P., McCurdy, M. T., Papali, A., Zubrow, M. T., Rodick, K. M., Hurley, J. M., & Verceles, A. C.
- Affiliations
- State University of New York (US)
- University of Pittsburgh (US)
- University of Maryland, Baltimore (US)
- Corresponding author
- Verceles, Avelino C.
- ORCID
- Venue
- Intensive and Critical Care Nursing
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 51
- Pages
- 45-49
- ISSN
- 0964-3397 (ISSN-L)
- OpenAlex
- W2902513030
- Cited by
- 20
- References
- 27
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 4 · 2022: 3 · 2021: 3 · 2020: 2 · 2019: 2
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Intensive and Critical Care Nursing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Keywords
- tele-ultrasound, point-of-care ultrasound, nurse training, procedural comfort, non-physician providers, tele-ICU, shock, respiratory failure, critical care nursing
- MeSH terms
- Clinical Competence, Humans, Nurses, Pilot Projects, Teaching, Ultrasonography, Cohort Studies, Telemedicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›