Bioactive electrospun nanocomposite scaffolds of poly(lactic acid)/cellulose nanocrystals for bone tissue engineering
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Poly(lactic acid) (PLA)/cellulose nanocrystal (CNC) composite scaffolds were fabricated using an electrospinning technique to evaluate the influence of CNCs on the biocompatibility and osteogenic potential of PLA. The scaffolds were characterized using Fourier transform infrared spectroscopy (FTIR), X-ray diffraction pattern (XRD), transmission electron microscopy (TEM), and atomic force microscopy (AFM). A significant enhancement of the mechanical properties occurred in the composite scaffolds compared to pure polymer. This is due to the stronger interactions between the polymer chains and CNCs. The composite scaffolds exhibited higher thermal stability compared to pure polymer. Notably, excellent adhesion and proliferation was observed in the presence of the fabricated composite scaffolds, indicating their superior biocompatibility. Higher mineralization was noted on the surface of composite scaffolds. The fabricated scaffolds were significantly covered by the cultured cells and exhibited greater fluorescence intensity vis-à-vis control. Additionally, the fact that higher expression of osteogenic gene markers was observed in composite scaffolds confirms their enhanced osteogenic potential. The bone regeneration potential of the fabricated scaffold was monitored in a rat calvarial defect model after 3 weeks of treatment. The fabricated scaffold demonstrated excellent biocompatibility and superior osteoinductivity. Therefore, the fabricated scaffolds possess potential to be used as a biomaterial for tissue engineering applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellulose nanomaterials review: structure, properties and nanocomposites
Moon, R. J., Martini, A., Nairn, J., Simonsen, J., & Youngblood, J. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00108b · Cited by 6,756
Electrospinning: Applications in drug delivery and tissue engineering
Sill, T. J., & von Recum, H. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.011 · Cited by 3,289
Large-scale production, properties and commercial applications of polylactic acid polymers
Lunt, J. (1998) · Polymer Degradation and Stability · doi:10.1016/s0141-3910(97)00148-1 · Cited by 1,366
Polylactide (PLA)-based nanocomposites
Raquez, J.-M., Habibi, Y., Murariu, M., & Dubois, P. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.05.014 · Cited by 1,209
Bacakova, L., Filova, E., Parizek, M., Ruml, T., & Svorcik, V. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.004 · Cited by 1,000
Mathew, A. P., Oksman, K., & Sain, M. (2005) · Journal of Applied Polymer Science · doi:10.1002/app.21779 · Cited by 851
Research progress in toughening modification of poly(lactic acid)
Liu, H., & Zhang, J. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22283 · Cited by 767
Fortunati, E., Armentano, I., Zhou, Q., Iannoni, A., Saino, E., Visai, L., Berglund, L. A., & Kenny, J. M. (2012) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2011.09.066 · Cited by 581
Influence of graphene on self-assembly of polyurethane and evaluation of its biomedical properties
Patel, D. K., Rana, D., Aswal, V. K., Srivastava, S., Roy, P., & Maiti, P. (2015) · Polymer · doi:10.1016/j.polymer.2015.03.076 · Cited by 41
Self-citation
Cited by
A Comparative Review of Natural and Synthetic Biopolymer Composite Scaffolds
Reddy, M. S. B., Ponnamma, D., Choudhary, R., & Sadasivuni, K. K. (2021) · Polymers · doi:10.3390/polym13071105 · Cited by 1,104
Arif, Z. U., Khalid, M. Y., Noroozi, R., Sadeghianmaryan, A., Jalalvand, M., & Hossain, M. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.07.140 · Cited by 395
Cellulose-based composite scaffolds for bone tissue engineering and localized drug delivery
Janmohammadi, M., Nazemi, Z., Salehi, A. O. M., Seyfoori, A., John, J. V., Nourbakhsh, M. S., & Akbari, M. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.05.018 · Cited by 323
What affects the biocompatibility of polymers?
Jurak, M., Wiącek, A. E., Ładniak, A., Przykaza, K., & Szafran, K. (2021) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2021.102451 · Cited by 239
Dutta, S. D., Hexiu, J., Patel, D. K., Ganguly, K., & Lim, K.-T. (2021) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2020.12.011 · Cited by 236
Self-citation
Metadata
- Authors
- Patel, D. K., Dutta, S. D., Hexiu, J., Ganguly, K., & Lim, K.-T.
- Venue
- International Journal of Biological Macromolecules
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 162
- Pages
- 1429-1441
- ISSN
- 0141-8130 (ISSN-L)
- OpenAlex
- W3046544065
- Cited by
- 122
- References
- 9
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.