Optimal sizing and location of renewable energy based DG units in distribution systems considering load growth
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In recent years, scientists have extensively focused on renewable energy resources such as wind power and solar units to reduce the consumption of fossil fuels as the main source of environmental pollutions. One of the main challenges for the production of wind and solar energies is that they often involve uncertainties due to the stochastic natures of wind speeds and solar radiation. Therefore, the existing uncertainties in the resources of wind and solar units must be considered in the planning procedure of distribution systems for having a reliable performance. To consider uncertainties in the output power of renewable energy resources, a new formulation is proposed to determine the optimal location and sizing of solar and wind units in the distribution system. To achieve this, Particle Swarm Optimization (PSO) algorithm as a robust technique is employed to find the best location and sizing of wind, solar and fuel cell units in the distribution system. The main objective of the present work is to minimize the Total Harmonic Distortion (THD), the total power losses, the total cost of DG units (including investments, replacement, operation and maintenance costs) and greenhouse gas emissions. Different types of loads such as linear and non-linear loads as well as load growth are also considered in the distribution system. To demonstrate the effectiveness of the proposed algorithm, 31-bus test system is considered as the case study. Our findings show that the use of renewable energy resources significantly reduces the greenhouse gas emissions in the mentioned system. Furthermore, the simulation results reveal that DG units must be added at some years to keep the voltage within its allowable limits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Summary of Distributed Resources Impact on Power Delivery Systems
Walling, R. A., Saint, R., Dugan, R. C., Burke, J., & Kojovic, L. A. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.909115 · Cited by 1,024
Cited by
Radosavljevic, J., Arsic, N., Milovanovic, M., & Ktena, A. (2020) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2019.000259 · Cited by 122
Sadeghian, H., & Wang, Z. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.09.117 · Cited by 64
Metadata
- Authors
- HassanzadehFard, H., & Jalilian, A.
- Venue
- International Journal of Electrical Power & Energy Systems
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 101
- Pages
- 356-370
- ISSN
- 0142-0615 (ISSN-L)
- OpenAlex
- W2795831183
- Cited by
- 172
- References
- 1
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal sizing and location of renewable energy based DG units in distribution systems considering load growth. https://app.cochat.ai/papers/10.1016/j.ijepes.2018.03.038
- The paper
- HassanzadehFard, H., & Jalilian, A. (2018). Optimal sizing and location of renewable energy based DG units in distribution systems considering load growth. International Journal of Electrical Power & Energy Systems. https://doi.org/10.1016/j.ijepes.2018.03.038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.