Optimal sizing and location of renewable energy based DG units in distribution systems considering load growth
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
In recent years, scientists have extensively focused on renewable energy resources such as wind power and solar units to reduce the consumption of fossil fuels as the main source of environmental pollutions. One of the main challenges for the production of wind and solar energies is that they often involve uncertainties due to the stochastic natures of wind speeds and solar radiation. Therefore, the existing uncertainties in the resources of wind and solar units must be considered in the planning procedure of distribution systems for having a reliable performance. To consider uncertainties in the output power of renewable energy resources, a new formulation is proposed to determine the optimal location and sizing of solar and wind units in the distribution system. To achieve this, Particle Swarm Optimization (PSO) algorithm as a robust technique is employed to find the best location and sizing of wind, solar and fuel cell units in the distribution system. The main objective of the present work is to minimize the Total Harmonic Distortion (THD), the total power losses, the total cost of DG units (including investments, replacement, operation and maintenance costs) and greenhouse gas emissions. Different types of loads such as linear and non-linear loads as well as load growth are also considered in the distribution system. To demonstrate the effectiveness of the proposed algorithm, 31-bus test system is considered as the case study. Our findings show that the use of renewable energy resources significantly reduces the greenhouse gas emissions in the mentioned system. Furthermore, the simulation results reveal that DG units must be added at some years to keep the voltage within its allowable limits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kennedy, J., & Eberhart, R. (2002) · Proceedings of ICNN'95 - International Conference on Neural Networks · doi:10.1109/icnn.1995.488968 · Cited by 58,192
Role of renewable energy sources in environmental protection: A review
Panwar, N. L., Kaushik, S. C., & Kothari, S. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.11.037 · Cited by 3,897
A compensation-based power flow method for weakly meshed distribution and transmission networks
Shirmohammadi, D., Hong, H. W., Semlyen, A., & Luo, G. X. (1988) · IEEE Transactions on Power Systems · doi:10.1109/59.192932 · Cited by 1,182
Summary of Distributed Resources Impact on Power Delivery Systems
Walling, R. A., Saint, R., Dugan, R. C., Burke, J., & Kojovic, L. A. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.909115 · Cited by 1,024
A three-phase power flow method for real-time distribution system analysis
Cheng, C. S., & Shirmohammadi, D. (1995) · IEEE Transactions on Power Systems · doi:10.1109/59.387902 · Cited by 854
Optimal sizing of hybrid PV/diesel/battery in ship power system
Lan, H., Wen, S., Hong, Y.-Y., Yu, D. C., & Zhang, L. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.08.031 · Cited by 413
Kalinci, Y., Hepbasli, A., & Dincer, I. (2015) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2014.10.147 · Cited by 342
Optimal sizing and siting techniques for distributed generation in distribution systems: A review
Prakash, P., & Khatod, D. K. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.099 · Cited by 329
Martín García, J. A., & Gil Mena, A. J. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.02.023 · Cited by 308
Mashayekh, S., Stadler, M., Cardoso, G., & Heleno, M. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.11.020 · Cited by 267
Pandi, V. R., Zeineldin, H. H., & Xiao, W. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2209687 · Cited by 244
Grainger, J. J., & Civanlar, S. (1985) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1985.318842 · Cited by 230
Rueda-Medina, A. C., Franco, J. F., Rider, M. J., Padilha-Feltrin, A., & Romero, R. (2013) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.12.009 · Cited by 227
Devabalaji, K. R., Ravi, K., & Kothari, D. P. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.03.008 · Cited by 225
Zeinalzadeh, A., Mohammadi, Y., & Moradi, M. H. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.12.010 · Cited by 211
Civanlar, S., & Grainger, J. J. (1985) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1985.318844 · Cited by 209
Ahmadi, S., & Abdi, S. (2016) · Solar Energy · doi:10.1016/j.solener.2016.05.019 · Cited by 209
Optimal sizing of a hybrid grid-connected photovoltaic and wind power system
González, A., Riba, J., Rius, A., & Puig, R. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.04.105 · Cited by 187
Lipman, T. E., Edwards, J. L., & Kammen, D. M. (2003) · Energy Policy · doi:10.1016/s0301-4215(02)00286-0 · Cited by 168
Devi, S., & Geethanjali, M. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.10.010 · Cited by 168
Doagou‐Mojarrad, H., Gharehpetian, G. B., Rastegar, H., & Olamaei, J. (2013) · Energy · doi:10.1016/j.energy.2013.01.043 · Cited by 167
Backward/Forward Sweep-Based Harmonic Analysis Method for Distribution Systems
Teng, J.-H., & Chang, C.-Y. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899523 · Cited by 161
A PSO-based approach to optimal capacitor placement with harmonic distortion consideration
Xin-mei, Y., Xin-yin, X., & Wu, Y. (2004) · Electric Power Systems Research · doi:10.1016/j.epsr.2004.01.002 · Cited by 148
Optimal location and sizing of distributed generation unit using intelligent water drop algorithm
Prabha, D. R., Jayabarathi, T., Umamageswari, R., & Saranya, S. (2015) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2015.07.003 · Cited by 128
Yammani, C., Sydulu, M., & Matam, S. K. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2016.01.003 · Cited by 122
Bhumkittipich, K. N., & Phuangpornpitak, N. (2013) · Energy Procedia · doi:10.1016/j.egypro.2013.06.759 · Cited by 109
Optimization of grid-connected microgrid consisting of PV/FC/UC with considered frequency control
HassanzadehFard, H., Moghaddas‐Tafreshi, S. M., & Hakimi, S. M. (2015) · TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES · doi:10.3906/elk-1111-28 · Cited by 38
Self-citationOptimal sizing of distributed generation considering uncertainties in a hybrid power system
Abd-el-Motaleb, A. M., & Bekdach, S. K. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2016.03.023 · Cited by 33
Kadir, A. F. A., Mohamed, A., Shareef, H., Ibrahim, A. A., Khatib, T., & Elmenreich, W. (2014) · Journal of Renewable and Sustainable Energy · doi:10.1063/1.4878997 · Cited by 33
Rasid, M. M., Murata, J., & Takano, H. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.10.030 · Cited by 18
Cited by
Radosavljevic, J., Arsic, N., Milovanovic, M., & Ktena, A. (2020) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2019.000259 · Cited by 122
Sadeghian, H., & Wang, Z. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.09.117 · Cited by 64
Metadata
- Authors
- HassanzadehFard, H., & Jalilian, A.
- Venue
- International Journal of Electrical Power & Energy Systems
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 101
- Pages
- 356-370
- ISSN
- 0142-0615 (ISSN-L)
- OpenAlex
- W2795831183
- Cited by
- 172
- References
- 30
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.