The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
A comprehensive review of virtual synchronous generator
Abstract
Abstract The renewable energy resources based distributed generation (DG) unit’s integration into the power system is growing rapidly, and the power system experiencing low inertia and damping, which causes severe stability and performance issues of the power system. In order to facilitate the integration of DG into the existing power system, improved control schemes for grid-tied electronic converters are necessary to ensure the stability and support to the power system. The virtual-synchronous generator (VSG) control emulates the dynamics of the rotation synchronous generator and enhances the stability of the power system. In this paper, an overview of different topologies to virtual inertia is presented along with a detailed description of the VSG structure. Moreover, VSG control defining active and reactive power control, and voltage and frequency control is explained in detail. The VSG stability analysis methods, such as small signal stability and transient stability are presented in comprehensive manners. Later on, the VSG application fields are described. Finally, the VSG problems and future research directions such as centralised control, stability improvement, reliable modelling, the interface for VSG are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luo, X., Wang, J., Dooner, M., & Clarke, J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.09.081 · Cited by 3,869
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Hatziargyriou, N., Asano, H., Iravani, R., & Marnay, C. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2007.376583 · Cited by 2,519
Energy storage technologies and real life applications – A state of the art review
Aneke, M., & Wang, M. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.06.097 · Cited by 1,754
Microgrids: A review of technologies, key drivers, and outstanding issues
Hirsch, A., Parag, Y., & Guerrero, J. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.040 · Cited by 1,493
Kroposki, B., Johnson, B., Zhang, Y., Gevorgian, V., Denholm, P., Hodge, B.-M., & Hannegan, B. (2017) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2016.2637122 · Cited by 1,367
Liu, J., Miura, Y., & Ise, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465852 · Cited by 1,243
Micro-Grid Autonomous Operation During and Subsequent to Islanding Process
Katiraei, F., Iravani, M. R., & Lehn, P. W. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.835051 · Cited by 1,150
Beck, H.-P., & Hesse, R. (2007) · 2007 9th International Conference on Electrical Power Quality and Utilisation · doi:10.1109/epqu.2007.4424220 · Cited by 1,097
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Metadata
- Authors
- Cheema, K. M.
- Venue
- International Journal of Electrical Power & Energy Systems
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 120
- Pages
- 106006
- ISSN
- 0142-0615 (ISSN-L)
- OpenAlex
- W3012155092
- Cited by
- 288
- References
- 61
- FWCI
- 18.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comprehensive review of virtual synchronous generator. https://app.cochat.ai/papers/10.1016/j.ijepes.2020.106006
- The paper
- Cheema, K. M. (2020). A comprehensive review of virtual synchronous generator. International Journal of Electrical Power & Energy Systems. https://doi.org/10.1016/j.ijepes.2020.106006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.