Thermal conductivity measurement and sedimentation detection of aluminum oxide nanofluids by using the 3ω method
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holman, J. P. (1976) · Cited by 9,157
A treatise on electricity and magnetism
(1954) · Journal of the Franklin Institute · doi:10.1016/0016-0032(54)90053-8 · Cited by 9,077
Thermal Conductivity of Heterogeneous Two-Component Systems
Hamilton, R. L., & Crosser, O. K. (1962) · Industrial & Engineering Chemistry Fundamentals · doi:10.1021/i160003a005 · Cited by 3,672
Measuring Thermal Conductivity of Fluids Containing Oxide Nanoparticles
Lee, S., Choi, S. U.-S., Li, S., & Eastman, J. A. (1999) · Journal of Heat Transfer · doi:10.1115/1.2825978 · Cited by 3,066 · cited 1×
“DC or AC heat generation is applied to the hot wire, and the temperature change with time is measured to calculate the nanofluid thermal conductivity (Lee et al., 1999).”
BackgroundTemperature Dependence of Thermal Conductivity Enhancement for Nanofluids
Das, S. K., Putra, N., Thiesen, P., & Roetzel, W. (2003) · Journal of Heat Transfer · doi:10.1115/1.1571080 · Cited by 2,392 · cited 3×
“(1999) and Das et al. (2003). On the other hand, the present EG based nanofluids data shows relatively low thermal conductivity values compared to those of Lee et al.”
MethodResultInfluentialThermal Conductivity of Nanoparticle - Fluid Mixture
Wang, X., Xu, X., & Choi, S. U. S. (1999) · Journal of Thermophysics and Heat Transfer · doi:10.2514/2.6486 · Cited by 2,386
Heat Transfer: A Practical Approach
Çengel, Y. A. (1997) · Cited by 2,358
Masuda, H., Ebata, A., Teramae, K., & Hishinuma, N. (1993) · Netsu Bussei · doi:10.2963/jjtp.7.227 · Cited by 2,165
Heat transfer characteristics of nanofluids: a review
Wang, X.-Q., & Mujumdar, A. S. (2007) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2006.06.010 · Cited by 2,151 · cited 1×
“With only a small volume fraction of nanoparticles, generally less than 5%, the reported effective thermal conductivities of the nanofluids vary from a few percent increment to even a couple of folds (Wang and Mujumdar, 2007) compared with those of the pure base fluids.”
BackgroundThermal conductivity measurement from 30 to 750 K: the 3ω method
Cahill, D. G. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141498 · Cited by 1,928
Cited by
A review of nanofluid stability properties and characterization in stationary conditions
Ghadimi, A., Saidur, R., & Metselaar, H. S. C. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.04.014 · Cited by 1,174
Stability of nanofluid: A review
Chakraborty, S., & Panigrahi, P. K. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.115259 · Cited by 728
Enhanced thermal conductivity of nanofluids: a state-of-the-art review
Özerinç, S., Kakaç, S., & Yazıcıoğlu, A. G. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0524-4 · Cited by 629
Qiu, L., Zhu, N., Feng, Y., Michaelides, E. E., Żyła, G., Jing, D., Zhang, X., Norris, P. M., Markides, C. N., & Mahian, O. (2020) · Physics Reports · doi:10.1016/j.physrep.2019.12.001 · Cited by 523
Ionic thermoelectric supercapacitors
Zhao, D., Wang, H., Khan, Z. U., Chen, J. C., Gabrielsson, R., Jonsson, M. P., Berggren, M., & Crispin, X. (2016) · Energy & Environmental Science · doi:10.1039/c6ee00121a · Cited by 479
Said, Z., Sundar, L. S., Tiwari, A. K., Ali, H. M., Sheikholeslami, M., Bellos, E., & Babar, H. (2022) · Physics Reports · doi:10.1016/j.physrep.2021.07.002 · Cited by 391
Techniques for measuring the thermal conductivity of nanofluids: A review
Paul, G., Chopkar, M., Manna, I., & Das, P. K. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.03.017 · Cited by 375
Hemmat Esfe, M., Saedodin, S., Wongwises, S., & Toghraie, D. (2015) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-014-4328-8 · Cited by 309
Hattori, Y., Falgout, L., Lee, W., Jung, S., Poon, E., Lee, J. W., Na, I., Geisler, A., Sadhwani, D., Zhang, Y., et al. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400073 · Cited by 276
Self-citationPalacios, A., Cong, L., Navarro, M. E., Ding, Y., & Barreneche, C. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.03.020 · Cited by 237
Kakaç, S., & Pramuanjaroenkij, A. (2016) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2015.09.021 · Cited by 179
Heat flow at nanoparticle interfaces
Warzoha, R. J., & Fleischer, A. S. (2014) · Nano Energy · doi:10.1016/j.nanoen.2014.03.014 · Cited by 144
Yüksel, N. (2016) · Insulation Materials in Context of Sustainability · doi:10.5772/64157 · Cited by 143
“Because the current is driven at a frequency ω and the resistance changes at a frequency 2ω, a voltage at 3ω results [34].”
InfluentialLubner, S. D., Choi, J., Wehmeyer, G., Waag, B., Mishra, V., Natesan, H., Bischof, J. C., & Dames, C. (2015) · Review of Scientific Instruments · doi:10.1063/1.4905680 · Cited by 66
Li, Y., Shi, C., Liu, J., Liu, E., Shao, J., Chen, Z., Dorantes-Gonzalez, D. J., & Hu, X. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/1/015006 · Cited by 41
Bhardwaj, R. G., & Khare, N. (2022) · International Journal of Thermophysics · doi:10.1007/s10765-022-03056-3 · Cited by 25
Metadata
- Authors
- Oh, D.-W., Jain, A., Eaton, J. K., Goodson, K. E., & Lee, J. S.
- Venue
- International Journal of Heat and Fluid Flow
- Publisher
- Elsevier BV
- Published
- 2008-10
- Volume
- 29
- Issue
- 5
- Pages
- 1456-1461
- ISSN
- 0142-727X (ISSN-L)
- OpenAlex
- W2071333337
- Cited by
- 215
- References
- 17
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.