Critical operating conditions for prevention of frost formation in fin-tube heat exchangers
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ye et al.'s mathematical model's predicted frosting and frost-free regions were in good agreement with experimental results.
“The frosting and frost-free regions predicted by the developed mathematical model were in good agreement with the experimental results.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Ye et al. [45]
Cites
A one-dimensional model for frost formation on a cold flat surface
Lee, K.-S., Kim, W.-S., & Lee, T.-H. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(97)00074-4 · Cited by 296 · see citing works
Self-citationFrost formation with varying environmental parameters
Jones, B. W., & Parker, J. D. (1975) · Journal of Heat Transfer · doi:10.1115/1.3450350 · Cited by 171 · see citing works
Modelling of frost growth and densification
Le Gall, R., Grillot, J. M., & Jallut, C. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(96)00359-6 · Cited by 153 · see citing works
Xia, Y., & Jacobi, A. M. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.08.008 · Cited by 62 · see citing works
Modeling of frost formation over parallel cold plates
Ismail, K. A. R., & Salinas, C. S. (1999) · International Journal of Refrigeration · doi:10.1016/s0140-7007(98)00069-3 · Cited by 61 · see citing works
Modeling the Cooling Process Path of a Dehumidifying Coil Under Frosting Conditions
Mago, P. J., & Sherif, D. S. A. (2002) · Journal of Heat Transfer · doi:10.1115/1.1494451 · Cited by 20 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
- Authors
- Ye, H.-Y., Park, J.-S., & Lee, K.-S.
- Affiliations
- Korea Atomic Energy Research Institute (KR)
- Hanyang University (KR)
- Corresponding author
- Lee, Kwan-Soo
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2014-09
- Volume
- 76
- Pages
- 279-285
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W1994472107
- Cited by
- 13
- References
- 6
- Citations by year
- 2023: 2 · 2022: 2 · 2021: 1 · 2018: 3 · 2017: 1 · 2016: 3 · 2014: 1
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Funders
- Ministry of Education, Science and Technology (2013R1A2A2A01067816)
- National Research Foundation of Korea
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- frost formation, finned tube heat exchanger, air-source heat pump, frost protection, critical operating conditions, dew point, heat and mass transfer modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review