Abstract

Whenever humid air comes in contact with a cooling coil whose temperature is below both the dew-point of water vapor in air and the freezing point, frost will form. The nature of the frost forming on the coil will depend to a large measure on the psychrometric conditions prevailing inside the freezer and whether the air around the coil is subsaturated or supersaturated. Psychrometric theory and the apparatus-dew-point calculating procedure assume that the cooling process path as the air passes through the coil is a straight-line on the psychrometric chart. The actual path is however a result of a much more complex series of processes and is therefore a curve. While researchers have calculated the actual process path on a dehumidifying coil, none has attempted to do the same for a frosted, multi-row coil. It is believed that determining the actual conditions leaving a given row in a multi-row freezer coil is a crucial step in identifying the coil location in the vicinity of which the transformation from the subsaturated zone to the supersaturated zone occurs. This will prove a key step in identifying a demarcation line between the unfavorable snow-like frost and the more traditional (and more favorable) frost formation patterns. Thus, the objective of this paper is to calculate the air path on an actual industrial-size finned-tube, multi-row coil utilizing experimentally derived data and correlate the shape of the path with the prevailing psychrometric conditions in the freezer in the hope of identifying the demarcation line in question.

Integrity signals

Registry

Crossref · 10.1115/1.1494451

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Mago and Sherif [3] calculated the overall heat transfer coefficient based on an enthalpy potential, but their method for computing the fin efficiency also neglected heat transfer in the frost layer parallel to the length of the fin.

    “Mago and Sherif [3] calculated the overall heat transfer coefficient based on an enthalpy potential, but their method for computing the fin efficiency also neglected heat transfer in the frost layer parallel to the length of the fin.”

Cites

Flagged first, then by citations

1 of the 17 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Mago, P. J., & Sherif, D. S. A.
Affiliations
  • Universidad de Oriente (VE)
  • Department of Mechanical and Aerospace Engineering, University of Florida, 228 MEB, P.O. Box 116300, Gainesville, FL 32611-6300
Venue
Journal of Heat Transfer
Publisher
Wiley
Published
2002-12-01
Volume
124
Issue
6
Pages
1182-1191
ISSN
  • 0022-1481 (ISSN-L)
  • 1528-8943
OpenAlex
W1987966266
Cited by
20
References
17
Citations by year
2026: 1 · 2024: 1 · 2021: 1 · 2015: 1 · 2014: 1
FWCI
11.20
Type
journal article
Language
en
Open access
closed
Locations
ASME Journal of Heat and Mass Transfer (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
Keywords
frost formation, psychrometric chart, dew point, demarcation line

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review