Cited by 266Thermodynamic and Exergetic Analyses of Power and Cooling SystemsSpacecraft and Cryogenic TechnologiesRefrigeration and Air Conditioning Technologies

The DOI matches its Crossref record; 55 of the 59 references it cites were found in a registry or an index.

Introducing and energy analysis of a novel cryogenic hydrogen liquefaction process configuration

Sadaghiani, Mirhadi S., Mehrpooya, Mehdi·2017·International Journal of Hydrogen Energy

Overview

Integrity signals

Registry

Crossref · 10.1016/j.ijhydene.2017.01.136

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 59 references

Research works printed but not linked: 1

  1. Mehdi Mehrpooya, 2015, Optimum design and exergy analysis of a novel cryogenic air separation process with LNG (liquefied natural gas) cold energy utilization, Energy, 90, 2047, 10.1016/j.energy.2015.07.101 · DOI

Cited by

Sorted by citations

See all 266

Metadata

Authors
Sadaghiani, M. S., & Mehrpooya, M.
Affiliations
University of Tehran (IR)
Corresponding author
Mehrpooya, Mehdi
Venue
International Journal of Hydrogen Energy
Publisher
Elsevier BV
Published
2017-03
Volume
42
Issue
9
Pages
6033-6050
ISSN
0360-3199 (ISSN-L)
OpenAlex
W2587279559
Cited by
266
References
59
Citations by year
2026: 33 · 2025: 39 · 2024: 42 · 2023: 41 · 2022: 33 · 2021: 28 · 2020: 16 · 2019: 16 · 2018: 10 · 2017: 8
FWCI
10.63
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Hydrogen Energy (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Thermodynamic and Exergetic Analyses of Power and Cooling Systems
  • Physical Sciences › Engineering › Aerospace Engineering › Spacecraft and Cryogenic Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
Keywords
hydrogen liquefaction, cryogenic liquefaction, refrigerant mixtures, two-stage refrigeration cycle, energy analysis, exergy analysis, coefficient of performance, exergy efficiency, heat exchanger design, expander design, power consumption

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review