Detection of mental fatigue state with wearable ECG devices
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Overwork-related disorders, such as cerebrovascular/cardiovascular diseases (CCVD) and mental disorders due to overwork, are a major occupational and public health issue worldwide, particularly in East Asian countries. Since wearable smart devices are inexpensive, convenient, popular and widely available today, we were interested in investigating the possibility of using wearable smart electrocardiogram (ECG) devices to detect the mental fatigue state. In total, 35 healthy participants were recruited from a public university in East China. Throughout the entire experiment, each participant wore a wearable device that was further linked to a smartphone to upload the data based on Bluetooth transmission. To manipulate the fatigue state, each participant was asked to finish a quiz, which lasted for approximately 80 min, with 30 logical referential and computing problems and 25 memory tests. Eight heart rate variability (HRV) indicators namely NN.mean (mean of normal to normal interval), rMSSD (root mean square of successive differences), PNN50 (the proportion of NN50 divided by total number of NNs), TP (total spectral power), HF (high frequency from 0.15 Hz to 0.4 Hz), LF (low frequency from 0.04 Hz to 0.15 Hz), VLF (very low frequency from 0.0033 Hz to 0.04 Hz) and the LF/HF ratio were collected at intervals of 5 min throughout the entire experiment. After the feature selection was performed, six indicators remained for further analysis, which were the NN.mean, rMSSD, PNN50, TP, LF, and VLF. Four algorithms, support vector machine (SVM), K-nearest neighbor (KNN), naïve Bayes (NB), and logistic regression (LR), were used to build classifiers that automatically detected the fatigue state. The best performance was achieved by KNN, which had a CV accuracy of 75.5%. The NN.mean, PNN50, TP and LF were the most important HRV indicators for mental fatigue detection. KNN performed the best among the four algorithms and had an average CV accuracy of 65.37% for all of the possible feature combinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Krupp, L. B. (1989) · Archives of Neurology · doi:10.1001/archneur.1989.00520460115022 · Cited by 6,172
Development of a fatigue scale
Chalder, T., Berelowitz, G., Pawlikowska, T., Watts, L., Wessely, S., Wright, D., & Wallace, E. P. (1993) · Journal of Psychosomatic Research · doi:10.1016/0022-3999(93)90081-p · Cited by 3,032
Quantification of Sleepiness: A New Approach
Hoddes, E., Zarcone, V., Smythe, H., Phillips, R., & Dement, W. C. (1973) · Psychophysiology · doi:10.1111/j.1469-8986.1973.tb00801.x · Cited by 2,538
A critical review of the psychophysiology of driver fatigue
Lal, S. K. L., & Craig, A. (2001) · Biological Psychology · doi:10.1016/s0301-0511(00)00085-5 · Cited by 1,001
Human Physiology : From Cells to Systems
Sherwood, L. (1989) · Cited by 956
System architecture of a wireless body area sensor network for ubiquitous health monitoring
Otto, C., Milenković, A., Sanders, C., & Jovanov, E. (2005) · Journal of Multimedia · doi:10.5555/2010498.2010502 · Cited by 729
Work Stress and Employee Health
Ganster, D. C., & Schaubroeck, J. (1991) · Journal of Management · doi:10.1177/014920639101700202 · Cited by 682
Bower, J. E., Bak, K., Berger, A., Breitbart, W., Escalante, C. P., Ganz, P. A., Schnipper, H. H., Lacchetti, C., Ligibel, J. A., Lyman, G. H., et al. (2014) · Journal of Clinical Oncology · doi:10.1200/jco.2013.53.4495 · Cited by 671
Driver fatigue: Electroencephalography and psychological assessment
Lal, S. K. L., & Craig, A. (2002) · Psychophysiology · doi:10.1017/s0048577201393095 · Cited by 533
Cited by
Fatigue Monitoring Through Wearables: A State-of-the-Art Review
Adão Martins, N. R., Annaheim, S., Spengler, C. M., & Rossi, R. M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.790292 · Cited by 205
Metadata
- Authors
- Huang, S., Li, J., Zhang, P., & Zhang, W.
- Venue
- International Journal of Medical Informatics
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 119
- Pages
- 39-46
- ISSN
- 1386-5056 (ISSN-L)
- OpenAlex
- W2890168959
- Cited by
- 176
- References
- 46
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.