Generalizable machine learning for stress monitoring from wearable devices: A systematic literature review
Open accessThe DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Wearable sensors have shown promise as a non-intrusive method for collecting biomarkers that may correlate with levels of elevated stress. Stressors cause a variety of biological responses, and these physiological reactions can be measured using biomarkers including Heart Rate Variability (HRV), Electrodermal Activity (EDA) and Heart Rate (HR) that represent the stress response from the Hypothalamic-Pituitary-Adrenal (HPA) axis, the Autonomic Nervous System (ANS), and the immune system. While Cortisol response magnitude remains the gold standard indicator for stress assessment [1], recent advances in wearable technologies have resulted in the availability of a number of consumer devices capable of recording HRV, EDA and HR sensor biomarkers, amongst other signals. At the same time, researchers have been applying machine learning techniques to the recorded biomarkers in order to build models that may be able to predict elevated levels of stress. OBJECTIVE: The aim of this review is to provide an overview of machine learning techniques utilized in prior research with a specific focus on model generalization when using these public datasets as training data. We also shed light on the challenges and opportunities that machine learning-enabled stress monitoring and detection face. METHODS: This study reviewed published works contributing and/or using public datasets designed for detecting stress and their associated machine learning methods. The electronic databases of Google Scholar, Crossref, DOAJ and PubMed were searched for relevant articles and a total of 33 articles were identified and included in the final analysis. The reviewed works were synthesized into three categories of publicly available stress datasets, machine learning techniques applied using those, and future research directions. For the machine learning studies reviewed, we provide an analysis of their approach to results validation and model generalization. The quality assessment of the included studies was conducted in accordance with the IJMEDI checklist [2]. RESULTS: A number of public datasets were identified that are labeled for stress detection. These datasets were most commonly produced from sensor biomarker data recorded using the Empatica E4 device, a well-studied, medical-grade wrist-worn wearable that provides sensor biomarkers most notable to correlate with elevated levels of stress. Most of the reviewed datasets contain less than twenty-four hours of data, and the varied experimental conditions and labeling methodologies potentially limit their ability to generalize for unseen data. In addition, we discuss that previous works show shortcomings in areas such as their labeling protocols, lack of statistical power, validity of stress biomarkers, and model generalization ability. CONCLUSION: Health tracking and monitoring using wearable devices is growing in popularity, while the generalization of existing machine learning models still requires further study, and research in this area will continue to provide improvements as newer and more substantial datasets become available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Power Analysis for the Behavioral Sciences
Muller, K. (1989) · Technometrics · doi:10.1080/00401706.1989.10488618 · Cited by 99,167
SMOTE synthetic minority over-sampling technique
Chawla, N. V., Bowyer, K. W., Hall, L. O., & Kegelmeyer, W. P. (2002) · Journal of Artificial Intelligence Research · doi:10.1613/jair.953 · Cited by 32,865 · cited 3×
“Technique) [62], such as oversampling from noisy points.”
BackgroundProtective and Damaging Effects of Stress Mediators
McEwen, B. S. (1998) · New England Journal of Medicine · doi:10.1056/nejm199801153380307 · Cited by 6,733
Thayer, J. F., Åhs, F., Fredrikson, M., Sollers, J. J., & Wager, T. D. (2012) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2011.11.009 · Cited by 3,224
Autonomic nervous system activity in emotion: a review
Kreibig, S. D. (2010) · Biological Psychology · doi:10.1016/j.biopsycho.2010.03.010 · Cited by 3,188 · cited 1×
“In [69], the author noted summary windows of 30 and 60 seconds are most often utilized, based on the hypothesis that this factor correlates with physiological response.”
BackgroundCalculating the sample size required for developing a clinical prediction model
Riley, R. D., Ensor, J., Snell, K. I. E., Harrell, F. E., Martin, G. P., Reitsma, J. B., Moons, K. G. M., Collins, G., & van Smeden, M. (2020) · BMJ · doi:10.1136/bmj.m441 · Cited by 2,917
Stress and Heart Rate Variability: A Meta-Analysis and Review of the Literature
Kim, H.-G., Cheon, E.-J., Bai, D.-S., Lee, Y. H., & Koo, B.-H. (2018) · Psychiatry Investigation · doi:10.30773/pi.2017.08.17 · Cited by 2,308 · cited 1×
“At present, a universally recognized standard for stress evaluation remains outstanding [4], further compounded with the need for a comprehensive framework for investigating how organisms function in and adapt to constantly changing environments [5].”
BackgroundMore than a feeling: A unified view of stress measurement for population science
Epel, E. S., Crosswell, A. D., Mayer, S. E., Prather, A. A., Slavich, G. M., Puterman, E., & Mendes, W. B. (2018) · Frontiers in Neuroendocrinology · doi:10.1016/j.yfrne.2018.03.001 · Cited by 1,077 · cited 1×
“In [86], the authors concluded that, the appraisal process critically shapes an individual’s response to acute stress, while [87] detected lower EDA biomarker activity in response to episodes of acute stress in caregivers of people with Autism Spectrum Disorder, a potential habituation to stress.”
BackgroundBrysbaert, M. (2019) · Journal of Cognition · doi:10.5334/joc.72 · Cited by 996
The Quantified Self: Fundamental Disruption in Big Data Science and Biological Discovery
Swan, M. (2013) · Big Data · doi:10.1089/big.2012.0002 · Cited by 931
A survey on addressing high-class imbalance in big data
Leevy, J. L., Khoshgoftaar, T. M., Bauder, R. A., & Seliya, N. (2018) · Journal of Big Data · doi:10.1186/s40537-018-0151-6 · Cited by 759 · cited 1×
“92% Simple implementation [64] Promotes overfitting [65] [14] Downsampling of Majority Class 93.”
BackgroundClassification with class imbalance problem: A review
Ali, A., Shamsuddin, S. M., & Ralescu, A. (2015) · Cited by 526
Peake, J. M., Kerr, G., & Sullivan, J. P. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00743 · Cited by 523 · cited 2×
“[17] performed a critical review of available wearable devices for providing bio-feedback, monitoring stress, and sleep with a critical review of their technical characteristics, reliability and validation.”
BackgroundA Review on Mental Stress Detection Using Wearable Sensors and Machine Learning Techniques
Gedam, S., & Paul, S. (2021) · IEEE Access · doi:10.1109/access.2021.3085502 · Cited by 467 · cited 3×
“In [35], Gedam and Paul have surveyed works that have performed stress detection using wearable sensors measuring Electrocardiogram (ECG), Electroencephalography (EEG), and Photoplethysmography (PPG) signals and surveyed machine learning techniques for that.”
BackgroundMethodA daily stress inventory: Development, reliability, and validity
Brantley, P. J., Waggoner, C. D., Jones, G. N., & Rappaport, N. B. (1987) · Journal of Behavioral Medicine · doi:10.1007/bf00845128 · Cited by 428
Hyperparameter Tuning for Machine Learning Algorithms Used for Arabic Sentiment Analysis
Elgeldawi, E., Sayed, A., Galal, A. R., & Zaki, A. M. (2021) · Informatics · doi:10.3390/informatics8040079 · Cited by 399 · cited 1×
“Due to the large number of parameters that require tuning in different algorithms, automated methods [70] have been developed to scan the full parameter search space in a reasonable amount of time to determine the optimal combination.”
MethodElreedy, D., Atiya, A. F., & Kamalov, F. (2024) · Machine Learning · doi:10.1007/s10994-022-06296-4 · Cited by 388 · cited 1×
“30% Surpasses random sampling methods [66] Introduces noise, Overgeneralization [61] [12] Downsampling of Majority Class 74.”
MethodMonitoring stress with a wrist device using context
Gjoreski, M., Luštrek, M., Gams, M., & Gjoreski, H. (2017) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2017.08.006 · Cited by 352 · cited 5×
“Interestingly, a growing number of studies are examining the effects of training machine learning models on biomarker data collected in a study setting compared to daily life scenarios [12], with further studies examining the effect of context when both training and evaluating predictive power [13].”
BackgroundMethodInfluentialCan, Y. S., Chalabianloo, N., Ekiz, D., & Ersoy, C. (2019) · Sensors · doi:10.3390/s19081849 · Cited by 349 · cited 10×
“30% Reduces bias [63] Generates minority outliers [64] [29] Upsampling of Minority Class 97.”
BackgroundMethodInfluentialThe need to separate the wheat from the chaff in medical informatics
Cabitza, F., & Campagner, A. (2021) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2021.104510 · Cited by 276 · cited 3×
“The quality assessment of the included studies was conducted in accordance with the IJMEDI checklist [2].”
MethodLarge-scale wearable data reveal digital phenotypes for daily-life stress detection
Smets, E., Rios Velazquez, E., Schiavone, G., Chakroun, I., D’Hondt, E., De Raedt, W., Cornelis, J., Janssens, O., Van Hoecke, S., Claes, S., et al. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0074-9 · Cited by 250
Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review
Georgiou, K., Larentzakis, A. V., Khamis, N. N., Alsuhaibani, G. I., Alaska, Y. A., & Giallafos, E. J. (2018) · Folia Medica · doi:10.2478/folmed-2018-0012 · Cited by 244 · cited 1×
“[79] that found wearable devices can only be used as a surrogate for HRV at resting or mild exercise conditions, as their accuracy fades out with increasing exercise load, and Schuurmans et al.”
BackgroundRegalia, G., Onorati, F., Lai, M., Caborni, C., & Picard, R. W. (2019) · Epilepsy Research · doi:10.1016/j.eplepsyres.2019.02.007 · Cited by 240
Schuurmans, A. A. T., de Looff, P., Nijhof, K. S., Rosada, C., Scholte, R. H. J., Popma, A., & Otten, R. (2020) · Journal of Medical Systems · doi:10.1007/s10916-020-01648-w · Cited by 210
Gholamiangonabadi, D., Kiselov, N., & Grolinger, K. (2020) · IEEE Access · doi:10.1109/access.2020.3010715 · Cited by 196 · cited 1×
“cognitive load [22], physical activity [23], emotions [24] and specifically related to this review, stress [11, 13, 14, 22, 25–33].”
BackgroundHRV Features as Viable Physiological Markers for Stress Detection Using Wearable Devices
Dalmeida, K. M., & Masala, G. L. (2021) · Sensors · doi:10.3390/s21082873 · Cited by 184 · cited 6×
“AUC, unlike classification accuracy, is sensitive to class imbalance when there is a minority class.”
BackgroundMethodInfluentialProceedings of the 2022 SIAM International Conference on Data Mining (SDM)
(2022) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611977172 · Cited by 181
Milstein, N., & Gordon, I. (2020) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2020.00148 · Cited by 180 · cited 1×
“In [77], the authors found the Empatica E4 to be suitable for psychotherapy research focused on Inter-Beat Interval (IBI) and specific HRV measures, but failed to produce reliable EDA data and produced missing IBI data, especially when a subject is being more dynamic.”
BackgroundHardware Implementation of Deep Network Accelerators Towards Healthcare and Biomedical Applications
Azghadi, M. R., Lammie, C., Eshraghian, J. K., Payvand, M., Donati, E., Linares-Barranco, B., & Indiveri, G. (2020) · ResearchOnline - JCU (James Cook University) · doi:10.3929/ethz-b-000465927 · Cited by 176
Proceedings of the 33rd Annual ACM Symposium on Applied Computing
van Roosmalen, J., Vranken, H. P. E., van Eekelen, R. N., Haddad, H. M., Wainwright, R. L., & Chbeir, R. (2018) · doi:10.1145/3167132 · Cited by 154
Ghiasi, S., Greco, A., Barbieri, R., Scilingo, E. P., & Valenza, G. (2020) · Scientific Reports · doi:10.1038/s41598-020-62225-2 · Cited by 153 · cited 1×
“[83] proposed combining HRV and EDA correlates as a single index, rather than treating each as separate indicators of ANS changes.”
BackgroundSeizure detection using wearable sensors and machine learning: Setting a benchmark
Tang, J., El Atrache, R., Yu, S., Asif, U., Jackson, M., Roy, S., Mirmomeni, M., Cantley, S., Sheehan, T., Schubach, S., et al. (2021) · Epilepsia · doi:10.1111/epi.16967 · Cited by 146
2022 ACM Conference on Fairness Accountability and Transparency
(2022) · doi:10.1145/3531146 · Cited by 146
Stress Monitoring Using Wearable Sensors: A Pilot Study and Stress-Predict Dataset
Iqbal, T., Simpkin, A. J., Roshan, D., Glynn, N., Killilea, J., Walsh, J. C., Molloy, G. J., Ganly, S., Ryman, H., Coen, E., et al. (2022) · Sensors · doi:10.3390/s22218135 · Cited by 136 · cited 3×
“[39] specifically performed a power analysis and similarly concluded that at least 34 test subjects would be required to achieve 80% statistical power, and built their Stress-Predict dataset using 35 test subjects.”
MethodInfluentialStress and the Manager: Making It Work For You
Albrecht, K. O. (1979) · Medical Entomology and Zoology · Cited by 134
van Lier, H. G., Pieterse, M. E., Garde, A., Postel, M. G., de Haan, H. A., Vollenbroek-Hutten, M. M. R., Schraagen, J. M., & Noordzij, M. L. (2020) · Behavior Research Methods · doi:10.3758/s13428-019-01263-9 · Cited by 133
Stress Monitoring and Recent Advancements in Wearable Biosensors
Samson, C., & Koh, A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.01037 · Cited by 129 · cited 7×
“Gjoreski et al. [13] used greedy step-wise selection to identify the top features considered most useful for their specific machine learning model, and further noted that when sensor-specific features are used, PPG-based features achieved higher predictive accuracy results, followed by the IBI and HR-based features.”
BackgroundInfluentialDatasets for Cognitive Load Inference Using Wearable Sensors and Psychological Traits
Gjoreski, M., Kolenik, T., Knez, T., Luštrek, M., Gams, M., Gjoreski, H., & Pejović, V. (2020) · Applied Sciences · doi:10.3390/app10113843 · Cited by 122 · cited 9×
“In the context of stress detection, normalization and standardization were utilized by [14, 22, 28, 33, 46], with [22] experimenting on both raw and standardized data, and finding that standardization offered improved predictive performance across all 10 machine learning algorithms tested.”
BackgroundMethodInfluentialAcute Stress State Classification Based on Electrodermal Activity Modeling
Greco, A., Valenza, G., Lázaro, J. M., Rey, J. M. G., Aguiló, J., de la Cámara, C., Bailón, R., & Scilingo, E. P. (2021) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2021.3055294 · Cited by 113
Delmastro, F., Martino, F. D., & Dolciotti, C. (2020) · IEEE Access · doi:10.1109/access.2020.2985301 · Cited by 112 · cited 10×
“The SWELL, Toadstool and WESAD datasets were recorded with specific intervals to denote stressed/non-stressed periods for labeling.”
BackgroundMethodInfluentialEvaluating the Reproducibility of Physiological Stress Detection Models
Mishra, V., Sen, S., Chen, G., Tian, H., Rogers, J., Chen, C.-H., & Kotz, D. F. (2020) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3432220 · Cited by 107
Onorati, F., Regalia, G., Caborni, C., LaFrance, W. C., Jr., Blum, A. S., Bidwell, J., Liso, P. D., Atrache, R. E., Loddenkemper, T., Mohammadpour, F., et al. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.724904 · Cited by 104
Comparison of Machine Learning Techniques for Psychophysiological Stress Detection
Smets, E., Casale, P., Großekathöfer, U., Lamichhane, B., Raedt, W. D., Bogaerts, K., Diest, I. V., & Hoof, C. A. V. (2016) · Communications in computer and information science · doi:10.1007/978-3-319-32270-4_2 · Cited by 95 · cited 11×
“The SWELL, Toadstool and WESAD datasets were recorded with specific intervals to denote stressed/non-stressed periods for labeling.”
BackgroundMethodInfluentialObjective stress monitoring based on wearable sensors in everyday settings
Han, H. J., Labbaf, S., Borelli, J. L., Dutt, N. D., & Rahmani, A. M. (2020) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1759707 · Cited by 91 · cited 5×
“[31] did not specifically optimize hyperparameters, but built several kNN models with different parameter values for k (1, 3, 5, 7, 9) and selected the best performing model from those.”
MethodInfluentialCorrNet: Fine-Grained Emotion Recognition for Video Watching Using Wearable Physiological Sensors
Zhang, T., Ali, A. E., Wang, C., Hanjalić, A., & Cesar, P. S. (2020) · Sensors · doi:10.3390/s21010052 · Cited by 89
A New Oversampling Method Based on the Classification Contribution Degree
Jiang, Z., Pan, T., Zhang, C., & Yang, J. (2021) · Symmetry · doi:10.3390/sym13020194 · Cited by 88 · cited 2×
“[61] proposed a new oversampling method based on the classification contribution degree to deal with a number of shortcomings when using SMOTE (Synthetic Minority Oversampling”
MethodDownsampling for Binary Classification with a Highly Imbalanced Dataset Using Active Learning
Lee, W., & Seo, K. (2022) · Big Data Research · doi:10.1016/j.bdr.2022.100314 · Cited by 85 · cited 1×
“[60] used a semi-supervised technique known as Active Learning to mitigate the effect of imbalanced class labels.”
MethodAn evaluation of time series summary statistics as features for clinical prediction tasks
Guo, C., Lu, M., & Chen, J. (2020) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-020-1063-x · Cited by 78 · cited 2×
“[68] performed a study to evaluate summary statistics as features for clinical prediction tasks, and found that commonly used combinations of summary statistics such as [min, max, mean] and [min, max, mean, standard deviation (std)] achieved good prediction results in most cases.”
MethodStress Detection from Multimodal Wearable Sensor Data
Indikawati, F. I., & Winiarti, S. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/771/1/012028 · Cited by 76 · cited 8×
“The SWELL, Toadstool and WESAD datasets were recorded with specific intervals to denote stressed/non-stressed periods for labeling.”
BackgroundMethodInfluentialCan, Y. S., Gokay, D., Kılıç, D. R., Ekiz, D., Chalabianloo, N., & Ersoy, C. (2020) · Sensors · doi:10.3390/s20030838 · Cited by 72 · cited 7×
“Interestingly, a growing number of studies are examining the effects of training machine learning models on biomarker data collected in a study setting compared to daily life scenarios [12], with further studies examining the effect of context when both training and evaluating predictive power [13].”
BackgroundMethodInfluentialMachine Learning Ranks ECG as an Optimal Wearable Biosignal for Assessing Driving Stress
Elgendi, M., & Menon, C. (2020) · IEEE Access · doi:10.1109/access.2020.2974933 · Cited by 70
Li, J. J., & Tong, X. (2020) · Patterns · doi:10.1016/j.patter.2020.100115 · Cited by 66 · cited 1×
“[85] provides a detailed discussion and guidelines for choosing between the two strategies (hypothesis testing versus machine learning classification) when designing an experiment that can assist researchers in choosing a strategy and when required, validate whether their sample size contains sufficient power.”
BackgroundEhrhart, M., Resch, B., Havas, C. R., & Niederseer, D. (2022) · Sensors · doi:10.3390/s22165969 · Cited by 64 · cited 8×
“Paper Dataset Healthy Pregnancy Smoking Caffeine Alcohol Mental Disorders Cardiovascular Disease [28] WESAD • • • • • [14] WESAD • • • • • [43] Custom • • [48] Custom • [6] WESAD • • • • • [47] WESAD • • • • • [27] WESAD • • • • • [32] Custom • • • • [30] WESAD • • • • • [26] Custom • • [49] SWELL • • [45] WESAD • • •…”
BackgroundMethodInfluentialIqbal, T., Elahi, A., Redón, P., Vazquez, P., Wijns, W. C., & Shahzad, A. (2021) · Diagnostics · doi:10.3390/diagnostics11030556 · Cited by 63 · cited 3×
“Five studies [14, 22, 43, 48, 72] scored over 30, being of medium to higher quality.”
BackgroundMethodExploring Unsupervised Machine Learning Classification Methods for Physiological Stress Detection
Iqbal, T., Elahi, A., Wijns, W. C., & Shahzad, A. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.782756 · Cited by 61 · cited 7×
“The SWELL, Toadstool and WESAD datasets were recorded with specific intervals to denote stressed/non-stressed periods for labeling.”
MethodInfluentialSiirtola, P., & Röning, J. (2020) · Sensors · doi:10.3390/s20164402 · Cited by 61 · cited 6×
“To ensure consistent, comparable results, [11] utilized only data recorded from the right hand of each test subject, leaving the important question of sensor placement unanswered, and needing further study to confirm whether sensor”
BackgroundMethodInfluentialIqbal, T., Redon-Lurbe, P., Simpkin, A. J., Elahi, A., Ganly, S., Wijns, W. C., & Shahzad, A. (2021) · IEEE Access · doi:10.1109/access.2021.3082423 · Cited by 60 · cited 13×
“The SWELL, Toadstool and WESAD datasets were recorded with specific intervals to denote stressed/non-stressed periods for labeling.”
BackgroundMethodInfluentialObjective Measurement of Physician Stress in the Emergency Department Using a Wearable Sensor
Kaczor, E. E., Carreiro, S., Stapp, J., Chapman, B. P., & Indic, P. (2020) · Hawaii International Conference on System Sciences (HICSS) · doi:10.24251/hicss.2020.456 · Cited by 54
Seipäjärvi, S. M., Tuomola, A., Juurakko, J., Rottensteiner, M., Rissanen, A.-P. E., Kurkela, J. L. O., Kujala, U. M., Laukkanen, J. A., & Wikgren, J. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac6b7c · Cited by 47 · cited 1×
“[81] found that an HRV-based stress index mirrors responses of cortisol, and an HRV-based stress index may be used to quantify physiological responses to psychosocial stress across various health and age groups.”
MethodA systematic literature review on wearable health data publishing under differential privacy
Saifuzzaman, M., Ananna, T. N., Chowdhury, M. J. M., Ferdous, M. S., & Chowdhury, F. (2022) · International Journal of Information Security · doi:10.1007/s10207-021-00576-1 · Cited by 45 · cited 1×
“[55] conducted a Systematic Literature Review to identify, select and critically appraise research in DP to understand the different techniques available in wearable data publishing, and proposed a number of solutions for protecting patient privacy.”
BackgroundAcute Stress Assessment From Excess Cortisol Secretion: Fundamentals and Perspectives
Boucher, P., & Plusquellec, P. (2019) · Frontiers in Endocrinology · doi:10.3389/fendo.2019.00749 · Cited by 45 · cited 1×
“While Cortisol response magnitude remains the gold standard indicator for stress assessment [1], recent advances in wearable technologies have resulted in the availability of a number of consumer devices capable of recording HRV, EDA and HR sensor biomarkers, amongst other signals.”
BackgroundRuiz‐Robledillo, N., & Moya‐Albiol, L. (2013) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-013-1996-3 · Cited by 37 · cited 1×
“In [86], the authors concluded that, the appraisal process critically shapes an individual’s response to acute stress, while [87] detected lower EDA biomarker activity in response to episodes of acute stress in caregivers of people with Autism Spectrum Disorder, a potential habituation to stress.”
BackgroundDetection and Characterization of Physical Activity and Psychological Stress from Wristband Data
Sevil, M., Rashid, M. M., Askari, M. R., Maloney, Z., Hajizadeh, I., & Çınar, A. (2020) · Signals · doi:10.3390/signals1020011 · Cited by 36 · cited 10×
“Sevil et al. [33] utilized Bayesian optimization techniques for feature-selection.”
BackgroundMethodInfluentialAn Advanced Stress Detection Approach based on Processing Data from Wearable Wrist Devices
Alshamrani, M. I. (2021) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2021.0120745 · Cited by 33 · cited 9×
“The SWELL, Toadstool and WESAD datasets were recorded with specific intervals to denote stressed/non-stressed periods for labeling.”
MethodInfluentialWesterink, J. H. D. M., Rajae-Joordens, R. J. E., Ouwerkerk, M., van Dooren, M., Jelfs, S., Denissen, A. J. M., de Vries, E. P., & van Ee, R. (2020) · Frontiers in Computer Science · doi:10.3389/fcomp.2020.00039 · Cited by 31
Farrow, T. F. D., Johnson, N. K., Hunter, M. D., Barker, A. T., Wilkinson, I. D., & Woodruff, P. W. R. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00349 · Cited by 29 · cited 1×
“[54] concluded that EDA is a robust, reliable, non-subjective psycho-physiological biomarker of psychological stress within subjects, but not always between.”
BackgroundLiapis, A., Faliagka, E., Antonopoulos, C., Κεραμίδας, Γ., & Voros, N. S. (2021) · Electronics · doi:10.3390/electronics10131550 · Cited by 28 · cited 11×
“The SWELL, Toadstool and WESAD datasets were recorded with specific intervals to denote stressed/non-stressed periods for labeling.”
MethodInfluentialSimons, R., Koordeman, R., de Looff, P. C., & Otten, R. (2021) · JMIR Research Protocols · doi:10.2196/24911 · Cited by 14
Cited by
Alam, M. S. B., Lameesa, A., Sharmin, S., Afrin, S., Ahmed, S. F., Nikoo, M. R., & Gandomi, A. H. (2025) · Digital Communications and Networks · doi:10.1016/j.dcan.2025.04.001 · Cited by 9
Metadata
- Authors
- Vos, G., Trinh, K., Sarnyai, Z., & Rahimi Azghadi, M.
- Venue
- International Journal of Medical Informatics
- Publisher
- Elsevier BV
- Published
- 2023-05
- Volume
- 173
- Pages
- 105026
- ISSN
- 1386-5056 (ISSN-L)
- OpenAlex
- W4322625607
- Cited by
- 164
- References
- 70
- FWCI
- 8.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.