Top-down mass spectrometry of supercharged native protein–ligand complexes
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Tandem mass spectrometry (MS/MS) of intact, noncovalently-bound protein-ligand complexes can yield structural information on the site of ligand binding. Fourier transform ion cyclotron resonance (FT-ICR) top-down MS of the 29 kDa carbonic anhydrase-zinc complex and adenylate kinase bound to adenosine triphosphate (ATP) with collisionally activated dissociation (CAD) and/or electron capture dissociation (ECD) generates product ions that retain the ligand and their identities are consistent with the solution phase structure. Increasing gas phase protein charging from electrospray ionization (ESI) by the addition of supercharging reagents, such as m-nitrobenzyl alcohol and sulfolane, to the protein analyte solution improves the capability of MS/MS to generate holo-product ions. Top-down proteomics for protein sequencing can be enhanced by increasing analyte charging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 1×
“The development of electrospray ionization (ESI) and the ready generation of multiply charged molecules opened up the prospects for tandem mass spectrometry and top-down MS [3] (but this was predicted by Fenn, as he speculated that the ability of ESI to produce multiply charged ions “could make a most important contri…”
BackgroundExtending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Sinha, S., Lopes, D. H. J., Du, Z., Pang, E. S., Shanmugam, A., Lomakin, A., Talbiersky, P., Tennstaedt, A., McDaniel, K., Bakshi, R., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja206279b · Cited by 299
Self-citationMass spectrometry: come of age for structural and dynamical biology
Benesch, J. L., & Ruotolo, B. T. (2011) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2011.08.002 · Cited by 264
Zhou, M., Lantz, C., Brown, K. A., Ge, Y., Paša-Tolić, L., Loo, J. A., & Lermyte, F. (2020) · Chemical Science · doi:10.1039/d0sc04392c · Cited by 146
Self-citationZhou, M., Dagan, S., & Wysocki, V. H. (2013) · The Analyst · doi:10.1039/c2an36525a · Cited by 92
Wongkongkathep, P., Han, J. Y., Choi, T. S., Yin, S., Kim, H. I., & Loo, J. A. (2018) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-018-2002-2 · Cited by 71
“Structural features, such as the elucidation of metal binding sites, have been revealed using top-down MS with electron capture dissociation (ECD) and collisionally activated dissociation (CAD) [57, 59].”
Self-citationCrittenden, C. M., Novelli, E. T., Mehaffey, M. R., Xu, G. N., Giles, D. H., Fies, W. A., Dalby, K. N., Webb, L. J., & Brodbelt, J. S. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00066 · Cited by 24
Free Radical-Based Sequencing for Native Top-Down Mass Spectrometry
Rojas Ramírez, C., Murtada, R., Gao, J., & Ruotolo, B. T. (2022) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.2c00252 · Cited by 7
Metadata
- Authors
- Yin, S., & Loo, J. A.
- Venue
- International Journal of Mass Spectrometry
- Publisher
- Elsevier BV
- Published
- 2011-03
- Volume
- 300
- Issue
- 2-3
- Pages
- 118-122
- ISSN
- 1387-3806 (ISSN-L)
- OpenAlex
- W1988332348
- Cited by
- 125
- References
- 2
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.