Mechanical evaluation of a patient-specific additively manufactured subperiosteal jaw implant (AMSJI) using finite-element analysis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Edentulism with associated severe bone loss is a widespread condition that hinders the use of common dental implants. An additively manufactured subperiosteal jaw implant (AMSJI) was designed as an alternative solution for edentulous patients with Cawood and Howell class V-VIII bone atrophy. A biomechanical evaluation of this AMSJI for the maxilla in a Cawood and Howell class V patient was performed via finite-element analysis. Occlusal and bruxism forces were incorporated to assess the loading conditions in the mouth during daily activities. The results revealed a safe performance of the implant structure during the foreseen implantation period of 15 years when exerting average occlusion forces of 200 N. For the deteriorated state of class VIII bone atrophy, increased stresses on the AMSJI were evaluated, which predicted implant fatigue. In addition, excessive bruxism and maximal occlusion forces might induce implant failure due to fatigue. The models predicted bone ingrowth at the implant scaffolds, resulting in extra stability and secondary fixation. For all considered loading conditions, the maximal stresses were located at the AMSJI arms. This area is most sensitive to bending forces and, hence, allows for further design optimization. Finally, the implant is considered safe for normal daily occlusion activities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mommaerts, M. Y. (2019) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2018.08.001 · Cited by 74
Self-citation
Cited by
The atrophic edentulous alveolus. A preliminary study on a new generation of subperiosteal implants
Dimitroulis, G., Gupta, B., Wilson, I., & Hart, C. (2022) · Oral and Maxillofacial Surgery · doi:10.1007/s10006-022-01044-3 · Cited by 60
Cebrián Carretero, J. L., Del Castillo Pardo de Vera, J. L., Montesdeoca García, N., Garrido Martínez, P., Pampín Martínez, M. M., Aragón Niño, I., Navarro Cuéllar, I., & Navarro Cuéllar, C. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11154594 · Cited by 40
Vaira, L. A., Biglio, A., Favro, A., Salzano, G., Abbate, V., Lechien, J. R., & De Riu, G. (2024) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2024.01.003 · Cited by 38
Exceptional Cases Demand Exceptional Personalized Solutions: The Next Level in Dental Rehabilitation
Gellrich, N.-C., Korn, P., Jehn, P., Neuhaus, M., Lentge, F., & Rahlf, B. (2024) · Journal of Personalized Medicine · doi:10.3390/jpm14030294 · Cited by 15
Metadata
- Authors
- De Moor, E., Huys, S. E. F., van Lenthe, G. H., Mommaerts, M. Y., & Vander Sloten, J.
- Venue
- International Journal of Oral and Maxillofacial Surgery
- Publisher
- Elsevier BV
- Published
- 2022-03
- Volume
- 51
- Issue
- 3
- Pages
- 405-411
- ISSN
- 0901-5027 (ISSN-L)
- OpenAlex
- W3165869777
- Cited by
- 55
- References
- 1
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical evaluation of a patient-specific additively manufactured subperiosteal jaw implant (AMSJI) using finite-element analysis. https://app.cochat.ai/papers/10.1016/j.ijom.2021.05.011
- The paper
- De Moor, E., Huys, S. E. F., van Lenthe, G. H., Mommaerts, M. Y., & Vander Sloten, J. (2022). Mechanical evaluation of a patient-specific additively manufactured subperiosteal jaw implant (AMSJI) using finite-element analysis. International Journal of Oral and Maxillofacial Surgery. https://doi.org/10.1016/j.ijom.2021.05.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.