Using microfluidics for scalable manufacturing of nanomedicines from bench to GMP: A case study using protein-loaded liposomes
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Nanomedicines are well recognised for their ability to improve therapeutic outcomes. Yet, due to their complexity, nanomedicines are challenging and costly to produce using traditional manufacturing methods. For nanomedicines to be widely exploited, new manufacturing technologies must be adopted to reduce development costs and provide a consistent product. Within this study, we investigate microfluidic manufacture of nanomedicines. Using protein-loaded liposomes as a case study, we manufacture liposomes with tightly defined physico-chemical attributes (size, PDI, protein loading and release) from small-scale (1 mL) through to GMP volume production (200 mL/min). To achieve this, we investigate two different laminar flow microfluidic cartridge designs (based on a staggered herringbone design and a novel toroidal mixer design); for the first time we demonstrate the use of a new microfluidic cartridge design which delivers seamless scale-up production from bench-scale (12 mL/min) through GMP production requirements of over 20 L/h using the same standardised normal operating parameters. We also outline the application of tangential flow filtration for down-stream processing and high product yield. This work confirms that defined liposome products can be manufactured rapidly and reproducibly using a scale-independent production process, thereby de-risking the journey from bench to approved product.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liposomal drug delivery systems: From concept to clinical applications
Allen, T. M., & Cullis, P. R. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.037 · Cited by 4,839
Doxil® — The first FDA-approved nano-drug: Lessons learned
Barenholz, Y. (. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.03.020 · Cited by 4,792
The Onpattro story and the clinical translation of nanomedicines containing nucleic acid-based drugs
Akinc, A., Maier, M. A., Manoharan, M., Fitzgerald, K., Jayaraman, M., Barros, S., Ansell, S., Du, X., Hope, M. J., Madden, T. D., et al. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0591-y · Cited by 1,636
Microfluidic Synthesis of Highly Potent Limit-size Lipid Nanoparticles for In Vivo Delivery of siRNA
Belliveau, N. M., Huft, J., Lin, P. J., Chen, S., Leung, A. K., Leaver, T. J., Wild, A. W., Lee, J. B., Taylor, R. J., Tam, Y. K., et al. (2012) · Molecular Therapy - Nucleic Acids · doi:10.1038/mtna.2012.28 · Cited by 685
Self-citationPassive mixers in microfluidic systems: A review
Lee, C.-Y., Wang, W.-T., Liu, C.-C., & Fu, L.-M. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.10.122 · Cited by 550
Controlled Vesicle Self-Assembly in Microfluidic Channels with Hydrodynamic Focusing
Jahn, A., Vreeland, W. N., Gaitan, M., & Locascio, L. E. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0318030 · Cited by 537
Guzman, J., & Gates, B. C. (2004) · Journal of the American Chemical Society · doi:10.1021/ja039426e · Cited by 514
Microfluidic Directed Formation of Liposomes of Controlled Size
Jahn, A., Vreeland, W. N., DeVoe, D. L., Locascio, L. E., & Gaitan, M. (2007) · Langmuir · doi:10.1021/la070051a · Cited by 429
Zhigaltsev, I. V., Belliveau, N., Hafez, I., Leung, A. K. K., Huft, J., Hansen, C., & Cullis, P. R. (2012) · Langmuir · doi:10.1021/la204833h · Cited by 345
Evers, M. J. W., Kulkarni, J. A., van der Meel, R., Cullis, P. R., Vader, P., & Schiffelers, R. M. (2018) · Small Methods · doi:10.1002/smtd.201700375 · Cited by 332
Cited by
Liposomes: Advancements and innovation in the manufacturing process
Shah, S., Dhawan, V., Holm, R., Nagarsenker, M. S., & Perrie, Y. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.002 · Cited by 745
Self-citationMicrofluidic formulation of nanoparticles for biomedical applications
Shepherd, S. J., Issadore, D., & Mitchell, M. J. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120826 · Cited by 433
Microfluidic technologies and devices for lipid nanoparticle-based RNA delivery
Maeki, M., Uno, S., Niwa, A., Okada, Y., & Tokeshi, M. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.02.017 · Cited by 349
Manufacturing Considerations for the Development of Lipid Nanoparticles Using Microfluidics
Roces, C. B., Lou, G., Jain, N., Abraham, S., Thomas, A., Halbert, G. W., & Perrie, Y. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12111095 · Cited by 321
Self-citationScalable mRNA and siRNA Lipid Nanoparticle Production Using a Parallelized Microfluidic Device
Shepherd, S. J., Warzecha, C. C., Yadavali, S., El-Mayta, R., Alameh, M.-G., Wang, L., Weissman, D., Wilson, J. M., Issadore, D., & Mitchell, M. J. (2021) · Nano Letters · doi:10.1021/acs.nanolett.1c01353 · Cited by 317
A Historical Review of Brain Drug Delivery
Pardridge, W. M. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14061283 · Cited by 219
Kis, Z., Kontoravdi, C., Shattock, R., & Shah, N. (2020) · Vaccines · doi:10.3390/vaccines9010003 · Cited by 159
Metadata
- Authors
- Webb, C., Forbes, N., Roces, C. B., Anderluzzi, G., Lou, G., Abraham, S., Ingalls, L., Marshall, K., Leaver, T. J., Watts, J. A., Aylott, J. W., & Perrie, Y.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 582
- Pages
- 119266
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W3014928462
- Cited by
- 201
- References
- 46
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.