Air-side performance of a parallel-flow parallel-fin (PF2) heat exchanger in sequential frosting
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The frosting time of the PF2 heat exchanger was 13 min longer than that of the conventional parallel-flow serpentine-fin heat exchanger.
“The frosting time of the PF 2 heat exchanger was 13 min longer than that of the conventional parallel-flow serpentine-fin heat exchanger.”
The PF2 heat exchanger reached a steady state after 8 frosting/defrosting cycles, and a defrosting time of 3 min was estimated to be the most reasonable.
“The PF 2 heat exchanger reached a steady state after 8 frosting/defrosting cycles, and a defrosting time of 3 min was estimated to be the most reasonable.”
The heat transfer UA of the PF 2 heat exchanger was slightly lower than that of the PFSF heat exchanger.
“The heat transfer UA of the PF 2 heat exchanger was slightly lower than that of the PFSF heat exchanger.”
Cites
Xia, Y., Zhong, Y., Hrnjak, P. S., & Jacobi, A. M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.03.005 · Cited by 148 · see citing works
Self-citationZhang, P., & Hrnjak, P. S. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.11.006 · Cited by 75 · see citing works
Self-citationFrosting performance of tube fin heat exchangers with wavy and corrugated fins
Kondepudi, S. N., & O'Neal, D. L. (1991) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(91)90040-x · Cited by 71 · see citing works
PADHMANABHAN, S., CREMASCHI, L., & FISHER, D. (2011) · International Journal of Air-Conditioning and Refrigeration · doi:10.1142/s2010132511000600 · Cited by 29 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Amer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218 · see citing works
Hong, S. H., Jang, D. S., Yun, S., Baek, J. H., & Kim, Y. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.113306 · Cited by 89 · see citing works
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Dynamic Defrosting on Superhydrophobic and Biphilic Surfaces
Gurumukhi, Y., Chavan, S., Sett, S., Boyina, K., Ramesh, S., Sokalski, P., Fortelka, K., Lira, M., Park, D., Chen, J.-Y., et al. (2020) · Matter · doi:10.1016/j.matt.2020.06.029 · Cited by 73 · see citing works
Xu, B., Han, Q., Chen, J., Li, F., Wang, N., Li, D., & Pan, X. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.09.026 · Cited by 71 · see citing works
Xu, B., Zhang, C., Wang, Y., Chen, J., Xu, K., Li, F., & Wang, N. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.06.037 · Cited by 69 · see citing works
Zhang, L., Jiang, Y., Dong, J., Yao, Y., & Deng, S. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.09.016 · Cited by 65 · see citing works
Kim, K., Kim, M.-H., Kim, D. R., & Lee, K.-S. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.12.060 · Cited by 64 · see citing works
Moallem, E., Padhmanabhan, S., Cremaschi, L., & Fisher, D. E. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.08.010 · Cited by 61 · see citing works
Moallem, E., Hong, T., Cremaschi, L., & Fisher, D. E. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2012.09.009 · Cited by 57 · see citing works
Zhang, L., Jiang, Y., Dong, J., Yao, Y., & Deng, S. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.12.047 · Cited by 56 · see citing works
Experimental and numerical investigations of frost formation on wavy plates
Ma, Q., Wu, X., Chu, F., & Zhu, B. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.04.098 · Cited by 56 · see citing works
Zhang, L., Jiang, Y., Dong, J., Yao, Y., & Deng, S. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.114063 · Cited by 40 · see citing works
Li, F., Wu, S., Ma, Z., Zhao, R., & Huang, D. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118220 · Cited by 36 · see citing works
Li, Z., Wei, W., Wang, W., Sun, Y., Wang, S., Lin, Y., Huang, C., & Deng, S. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.122136 · Cited by 30 · see citing works
Sarmiento, A. P., de Sá Sarmiento, F. I. P., Shooshtari, A., & Ohadi, M. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123680 · Cited by 29 · see citing works
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26 · see citing works
Hrnjak, P., Zhang, P., & Rennels, C. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.08.002 · Cited by 24 · see citing works
Self-citationPark, J.-S., Kim, J., & Lee, K.-S. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.01.043 · Cited by 24 · see citing works
Flat tube heat exchangers: Experimental analysis of frosting and water retention
Westhaeuser, J., Brauchle, L., Albrecht, J.-C., Tegethoff, W., Lemke, N., & Koehler, J. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.119319 · Cited by 24 · see citing works
Experimental analysis of an air–water heat pump with micro-channel heat exchanger
Brignoli, R., Cecchinato, L., & Zilio, C. (2013) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.08.027 · Cited by 21 · see citing works
- Authors
- Zhang, P., & Hrnjak, P. S.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Corresponding author
- Hrnjak, P.S.
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2010-09
- Volume
- 33
- Issue
- 6
- Pages
- 1118-1128
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2061086053
- Cited by
- 59
- References
- 4
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 4 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 4 · 2019: 1 · 2018: 5 · 2017: 7 · 2016: 2 · 2015: 2 · 2014: 3 · 2013: 4 · 2012: 10
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- frost accumulation, thawing, pressure drop, thermal transmittance, water drainage, flat tube heat exchanger, air humidity, water retention
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review