Two-dimensional numerical modeling for the air-side of minichannel evaporators accounting for partial dehumidification scenarios and tube-to-tube heat conduction
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The epsilon-NTU method cannot capture the actual partial wet region of the fin because it assumes that the fin is fully wet.
“The ε -NTU method cannot capture the actual partial wet region of the fin because it assumes that the fin is fully wet.”
From Thermal-hydraulic and drainage performance of microchannel heat exchangers for refrigeration and heat pump systems under frosting, defrosting, and wet conditions: A comprehensive review (2023) · cites this paper as [114]
The Conclusions state that the ε-NTU model cannot capture the precise dehumidifying condition of a partially wet fin. But they say it permits 0%, 50%, or 100% wet conditions—not that it always assumes the fin is fully wet. The numerical-comparison section likewise describes separately classified wet and dry fin segments. Page numbers were not provided in our copy. (LLM, conf=0.89)
Experimental — accuracy not yet measuredLatent heat is always overestimated by the epsilon-NTU method, and the deviation of the total heat transfer rate between the two models is up to 52%.
“As a result, the latent heat is always overestimated by the ε -NTU method, and the deviation of the total heat transfer rate between the two models is up to 52%.”
From Thermal-hydraulic and drainage performance of microchannel heat exchangers for refrigeration and heat pump systems under frosting, defrosting, and wet conditions: A comprehensive review (2023) · cites this paper as [114]
The Conclusions report that total heat-transfer deviations reach 52% for Case III. But Section 2 says the ε-NTU model underestimates latent heat transfer under some studied conditions, so the claim that it always overestimates it is incorrect. (LLM, conf=0.90)
Experimental — accuracy not yet measuredThe two-dimensional numerical simulation model improves prediction accuracy while incurring a higher computational cost.
“It is clear that the two-dimensional numerical simulation model improves prediction accuracy while incurring a higher computational cost.”
From Thermal-hydraulic and drainage performance of microchannel heat exchangers for refrigeration and heat pump systems under frosting, defrosting, and wet conditions: A comprehensive review (2023) · cites this paper as [114]
The Conclusions (page unavailable) say the 2D Fin2D-W model captures fin dehumidification conditions more precisely than the classical ε-NTU model. Section 2 (page unavailable) describes ε-NTU as simple and fast, but the paper does not report a computational-cost comparison or explicitly establish that Fin2D-W incurs a higher cost. (LLM, conf=0.82)
Experimental — accuracy not yet measuredThe epsilon-NTU method is five times faster than the two-dimensional numerical model.
“The ε -NUT method is five times faster than the two-dimensional numerical model.”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Numerical Heat Transfer and Fluid Flow
Patankar, S. V. (2018) · CRC Press eBooks · doi:10.1201/9781482234213 · Cited by 23,406 · see citing works
Numerical Heat Transfer and Fluid Flow
Hsu, C. (1981) · Nuclear Science and Engineering · doi:10.13182/nse81-a20112 · Cited by 15,200 · see citing works
Fundamentals of heat and mass transfer
Hewitt, G. F. (2008) · Begellhouse eBooks · Cited by 12,932 · see citing works
Fundamentals of Heat and Mass Transfer
Azim, A. Y. A. (2011) · Cited by 5,433 · see citing works
Kays, W. M., London, A. L., & Eckert, E. R. G. (1960) · Journal of Applied Mechanics · doi:10.1115/1.3644004 · Cited by 2,846 · see citing works
Thermal environmental engineering
(1962) · Journal of the Franklin Institute · doi:10.1016/0016-0032(62)90922-5 · Cited by 927 · see citing works
CoilDesigner: a general-purpose simulation and design tool for air-to-refrigerant heat exchangers
Jiang, H., Aute, V., & Radermacher, R. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.09.019 · Cited by 209 · see citing works
Sharqawy, M. H., & Zubair, S. M. (2008) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2008.01.003 · Cited by 136 · see citing works
(2013) · CRC Press eBooks · doi:10.1201/b14877-8 · Cited by 133 · see citing works
Numerical and experimental studies of refrigerant circuitry of evaporator coils
Liang, S. Y., Wong, T. N., & Nathan, G. K. (2001) · International Journal of Refrigeration · doi:10.1016/s0140-7007(00)00050-5 · Cited by 99 · see citing works
Fin performance with condensation from humid air: a numerical investigation
Coney, J. E. R., Sheppard, C. G. W., & Elshafei, E. A. M. (1989) · International Journal of Heat and Fluid Flow · doi:10.1016/0142-727x(89)90041-6 · Cited by 74 · see citing works
Liang, S. Y., Wong, T. N., & Nathan, G. K. (2000) · Applied Thermal Engineering · doi:10.1016/s1359-4311(99)00078-2 · Cited by 67 · see citing works
de Córdoba, P. F. (2001) · Numerical Heat Transfer Part B Fundamentals · doi:10.1080/104077901300233596 · Cited by 63 · see citing works
(1994) · National University of Singapore · Cited by 63 · see citing works
Singh, V. P., Aute, V., & Radermacher, R. (2008) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.03.013 · Cited by 56 · see citing works
Thermal and hydraulic analysis of a brazed aluminum evaporator
Wu, X., & Webb, R. L. (2002) · Applied Thermal Engineering · doi:10.1016/s1359-4311(02)00058-3 · Cited by 49 · see citing works
Effects of thermal conduction in microchannel gas coolers for carbon dioxide
Asinari, P., Cecchinato, L., & Fornasieri, E. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2004.04.001 · Cited by 49 · see citing works
‘ART’ A Computer Code To Assist The Design Of Refrigeration and A/C Equipment
Corberán, J. M., Gonzálvez-Maciá, J., Montes-García, P., & Blasco, R. (2002) · Purdue e-Pubs (Purdue University System) · Cited by 44 · see citing works
Self-citationDevelopment of a mini-channel evaporator model using R1234yf as working fluid
Zhao, Y. H., Liang, Y., Sun, Y., & Chen, J. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2012.08.026 · Cited by 42 · see citing works
Dehumidification of Air on a Vertical Rectangular Fin: A Numerical Study
Coney, J. E. R., Kazeminejad, H., & Sheppard, C. G. W. (1989) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1243/pime_proc_1989_203_101_02 · Cited by 40 · see citing works
Ren, T., Ding, G., Wang, T., & Hu, H. (2013) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.06.035 · Cited by 38 · see citing works
Evaluation of microchannel condenser characteristics by numerical simulation
Yin, X.-W., Wang, W., Patnaik, V., Zhou, J.-S., & Huang, X.-C. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.03.006 · Cited by 27 · see citing works
Impact of classical assumptions in modelling a microchannel gas cooler
Martínez-Ballester, S., Corberán, J. M., Gonzálvez-Maciá, J., & Domanski, P. A. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.07.005 · Cited by 22 · see citing works
Self-citationThermodynamic optimization of evaporators with zeotropic refrigerant mixtures
Ragazzi, F. (1995) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign) · Cited by 18 · see citing works
Gossard, J. J., Han, X., Ramalingam, M. L., & Sommers, A. D. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.07.011 · Cited by 14 · see citing works
Hassan, A. H., Martinez-Ballester, S., & Gonzálvez-Maciá, J. (2015) · Science and Technology for the Built Environment · doi:10.1080/23744731.2015.1028866 · Cited by 7 · see citing works
Self-citationHuang, L., Bacellar, D., Aute, V., & Radermacher, R. (2015) · Science and Technology for the Built Environment · doi:10.1080/23744731.2015.1047717 · Cited by 7 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Recent advances in the applications of machine learning methods for heat exchanger modeling—a review
Zou, J., Hirokawa, T., An, J., Huang, L., & Camm, J. (2023) · Frontiers in Energy Research · doi:10.3389/fenrg.2023.1294531 · Cited by 56 · see citing works
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26 · see citing works
Machine Learning Assisted Microchannel Geometric Optimization—A Case Study of Channel Designs
Huang, L., Zou, J., Liu, B., Jin, Z.-J., & Qian, J.-Y. (2023) · Energies · doi:10.3390/en17010044 · Cited by 15 · see citing works
Du, R., Zou, J., An, J., & Huang, L. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121366 · Cited by 11 · see citing works
An imperative need for machine learning algorithms in heat transfer application: a review
Ramanipriya, M., & Anitha, S. (2024) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-024-13885-z · Cited by 9 · see citing works
Liu, B., Qian, J.-Y., Jin, Z.-J., Huang, L., & Zou, J. (2024) · Frontiers in Heat and Mass Transfer · doi:10.32604/fhmt.2024.058231 · Cited by 6 · see citing works
Ala, M., Şahin, M., Kılıç, M., & Dişken, G. (2025) · Çukurova Üniversitesi Mühendislik Fakültesi Dergisi · doi:10.21605/cukurovaumfd.1674303 · Cited by 5 · see citing works
Hassan, A. H., Martínez-Ballester, S., & Gonzálvez-Maciá, J. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.08.055 · Cited by 5 · see citing works
Self-citationComparison of different modeling approaches for minichannel evaporators under dehumidification
Hassan, A. H., Martínez-Ballester, S., & Gonzálvez-Maciá, J. (2019) · Heat and Mass Transfer · doi:10.1007/s00231-019-02622-0 · Cited by 2 · see citing works
Self-citationHassan, A. H., Gonzálvez-Maciá, J., Martínez-Ballester, S., & Cascales, J. R. G. (2016) · Purdue e-Pubs (Purdue University System)
Self-citation
- Authors
- Hassan, A. H., Martínez-Ballester, S., & Gonzálvez-Maciá, J.
- Affiliations
- Universitat Politècnica de València (ES)
- Corresponding author
- Martínez-Ballester, Santiago
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2016-07
- Volume
- 67
- Pages
- 90-101
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2319896116
- Cited by
- 10
- References
- 27
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 3 · 2022: 1 · 2019: 1 · 2017: 1 · 2016: 1
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- International Journal of Refrigeration (publishedVersion)
- RiuNet (Universitat Politècnica de València) (submittedVersion, cc-by-nc-nd)
- Funders
- Valencian Community (GRISOLIA/2012/005)
- Spanish Ministry of Economy and Finance (DPI2011-26771-C02-01)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- air-side heat transfer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review