CoChat

Outcomes of a new slowly resorbable biosynthetic mesh (Phasix™) in potentially contaminated incisional hernias: A prospective, multi-center, single-arm trial

van Rooijen, Mathilde MJ., Jairam, An P., Tollens, Tim, Jørgensen, Lars N., de Vries Reilingh, Tammo S., Piessen, Guillaume, Köckerling, Ferdinand, Miserez, Marc, Windsor, Alastair CJ., Berrevoet, Frederik, Fortelny, René H., Dousset, Bertrand, Woeste, Guido, van Westreenen, Henderik L., Gossetti, Francesco, Lange, Johan F., Tetteroo, Geert WM., Koch, Andreas, Kroese, Leonard F., Jeekel, Johannes · 2020 · International Journal of Surgery
Cited by 30

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Resorbable biomaterials have been developed to reduce the amount of foreign material remaining in the body after hernia repair over the long-term. However, on the short-term, these resorbable materials should render acceptable results with regard to complications, infections, and reoperations to be considered for repair. Additionally, the rate of resorption should not be any faster than collagen deposition and maturation; leading to early hernia recurrence. Therefore, the objective of this study was to collect data on the short-term performance of a new resorbable biosynthetic mesh (Phasix™) in patients requiring Ventral Hernia Working Group (VHWG) Grade 3 midline incisional hernia repair. MATERIALS AND METHODS: were included. Hernia repair was performed with Phasix™ Mesh in sublay position when achievable. The primary outcome was the rate of surgical site occurrence (SSO), including infections, that required intervention until 3 months after repair. RESULTS: In total, 84 patients were treated with Phasix™ Mesh. Twenty-two patients (26.2%) developed 32 surgical site occurrences. These included 11 surgical site infections, 9 wound dehiscences, 7 seromas, 2 hematomas, 2 skin necroses, and 1 fistula. No significant differences in surgical site occurrence development were found between groups repaired with or without component separation technique, and between clean-contaminated or contaminated wound sites. At three months, there were no hernia recurrences. CONCLUSION: Phasix™ Mesh demonstrated acceptable postoperative surgical site occurrence rates in patients with a Ventral Hernia Working Group Grade 3 hernia. Longer follow-up is needed to evaluate the recurrence rate and the effects on quality of life. This study is ongoing through 24 months of follow-up.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijsu.2020.08.053

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 38

  1. Luijendijk, 2000, A comparison of suture repair with mesh repair for incisional hernia, N. Engl. J. Med., 343, 392, 10.1056/NEJM200008103430603 · DOI · Paper page
  2. Sauerland, 2004, Obesity is a risk factor for recurrence after incisional hernia repair, Hernia, 8, 42, 10.1007/s10029-003-0161-x · DOI · Paper page
  3. van Ramshorst, 2012, Impact of incisional hernia on health-related quality of life and body image: a prospective cohort study, Am. J. Surg., 204, 144, 10.1016/j.amjsurg.2012.01.012 · DOI
  4. Poulose, 2012, Epidemiology and cost of ventral hernia repair: making the case for hernia research, Hernia, 16, 179, 10.1007/s10029-011-0879-9 · DOI · Paper page
  5. Burger, 2004, Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia, Ann. Surg., 240, 578, 10.1097/01.sla.0000141193.08524.e7 · DOI · Paper page
  6. Mathes, 2016, Suture versus mesh repair in primary and incisional ventral hernias: a systematic review and meta-analysis, World J. Surg., 40, 826, 10.1007/s00268-015-3311-2 · DOI · Paper page
  7. Cobb, 2005, Laparoscopic repair of incisional hernias, Surg. Clin., 85, 91
  8. Markar, 2010, Partially or completely absorbable versus nonabsorbable mesh repair for inguinal hernia: a systematic review and meta-analysis, Surg. Laparosc. Endosc. Percutaneous Tech., 20, 213, 10.1097/SLE.0b013e3181ed86a2 · DOI
  9. FitzGerald, 2014, Biologic versus synthetic mesh reinforcement: what are the pros and cons?, Clin. Colon Rectal Surg., 27, 140, 10.1055/s-0034-1394155 · DOI · Paper page
  10. Ventral Hernia Working Group, 2010, Incisional ventral hernias: review of the literature and recommendations regarding the grading and technique of repair, Surgery, 148, 544, 10.1016/j.surg.2010.01.008 · DOI · Paper page
  11. Zheng, 2004, Host response after reconstruction of abdominal wall defects with porcine dermal collagen in a rat model, Am. J. Obstet. Gynecol., 191, 1961, 10.1016/j.ajog.2004.01.091 · DOI
  12. Kissane, 2012, A decade of ventral incisional hernia repairs with biologic acellular dermal matrix: what have we learned?, Plast. Reconstr. Surg., 130, 194S, 10.1097/PRS.0b013e318265a5ec · DOI · Paper page
  13. Itani, 2012, Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH Study, Surgery, 152, 498, 10.1016/j.surg.2012.04.008 · DOI · Paper page
  14. Martin, 2013, Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications, J. Surg. Res., 184, 766, 10.1016/j.jss.2013.03.044 · DOI · Paper page
  15. Deeken, 2013, Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (Poly-4-hydroxybutyrate-PHASIX mesh) in a porcine model of hernia repair, ISRN Surg, 2013, 238067, 10.1155/2013/238067 · DOI · Paper page
  16. Chen, 2005, The application of polyhydroxyalkanoates as tissue engineering materials, Biomaterials, 26, 6565, 10.1016/j.biomaterials.2005.04.036 · DOI · Paper page
  17. Wu, 2009, Medical application of microbial biopolyesters polyhydroxyalkanoates, Artif. Cells Blood Substit. Immobil. Biotechno., 37, 1, 10.1080/10731190802664429 · DOI · Paper page
  18. van Rooijen, 2018, A post-market, prospective, multi-center, single-arm clinical investigation of Phasix mesh for VHWG grade 3 midline incisional hernia repair: a research protocol, BMC Surg., 18, 104, 10.1186/s12893-018-0439-7 · DOI
  19. Agha, 2019, STROCSS 2019 Guideline: strengthening the reporting of cohort studies in surgery, Int. J. Surg., 72, 156, 10.1016/j.ijsu.2019.11.002 · DOI · Paper page
  20. Won, 2015, Association of postoperative hyperglycemia with outcomes among patients with complex ventral hernia repair, JAMA Surg, 150, 433, 10.1001/jamasurg.2014.3160 · DOI
  21. Rodriguez-Unda, 2015, Negative-pressure wound therapy in the management of high-grade ventral hernia repairs, J. Gastrointest. Surg., 19, 2054, 10.1007/s11605-015-2894-0 · DOI
  22. Kugler, 2016, A dual-stage approach to contaminated, high-risk ventral hernia repairs, J. Surg. Res., 204, 200, 10.1016/j.jss.2016.04.065 · doi:10.1016/j.jss.2016.04.065
  23. Kanters, 2012, Modified hernia grading scale to stratify surgical site occurrence after open ventral hernia repairs, J. Am. Coll. Surg., 215, 787, 10.1016/j.jamcollsurg.2012.08.012 · DOI · Paper page
  24. Fligor, 2017, Current risk stratification systems are not generalizable across surgical technique in midline ventral hernia repair, Plast Reconstr Surg Glob Open, 5, 10.1097/GOX.0000000000001206 · DOI
  25. Slater, 2015, Large contaminated ventral hernia repair using component separation technique with synthetic mesh, Plast. Reconstr. Surg., 136, 796e, 10.1097/PRS.0000000000001793 · doi:10.1097/prs.0000000000001793
  26. Brahmbhatt, 2014, Identifying risk factors for surgical site complications after laparoscopic ventral hernia repair: evaluation of the Ventral Hernia Working Group grading system, Surg. Infect., 15, 187, 10.1089/sur.2012.179 · DOI · Paper page
  27. Diamond, 2015, Revising recommendations and outcome measurements after complex open abdominal wall reconstruction, Am. Surg., 81, 955, 10.1177/000313481508101009 · doi:10.1177/000313481508101009
  28. Carbonell, 2013, Outcomes of synthetic mesh in contaminated ventral hernia repairs, J. Am. Coll. Surg., 217, 991, 10.1016/j.jamcollsurg.2013.07.382 · DOI · Paper page
  29. Liang, 2014, Outcomes with porcine acellular dermal matrix versus synthetic mesh and suture in complicated open ventral hernia repair, Surg. Infect., 15, 506, 10.1089/sur.2013.090 · DOI
  30. Beale, 2012, The role of biologic mesh in abdominal wall reconstruction: a systematic review of the current literature, Am. J. Surg., 204, 510, 10.1016/j.amjsurg.2012.03.009 · DOI
  31. Atema, 2016, Systematic review and meta-analysis of the repair of potentially contaminated and contaminated abdominal wall defects, Am. J. Surg., 212, 982, 10.1016/j.amjsurg.2016.05.003 · DOI
  32. Bondre, 2016, Suture, synthetic, or biologic in contaminated ventral hernia repair, J. Surg. Res., 200, 488, 10.1016/j.jss.2015.09.007 · DOI
  33. Fischer, 2014, A comparison of outcomes and cost in VHWG grade II hernias between Rives-Stoppa synthetic mesh hernia repair versus underlay biologic mesh repair, Hernia, 18, 781, 10.1007/s10029-014-1309-6 · DOI
  34. Jones, 1989, Polypropylene mesh closure of infected abdominal wounds, Am. Surg., 55, 73
  35. Kim, 2006, Acellular dermal matrix in the management of high-risk abdominal wall defects, Am. J. Surg., 192, 705, 10.1016/j.amjsurg.2006.09.003 · DOI · Paper page
  36. Slater, 2013, Biologic grafts for ventral hernia repair: a systematic review, Am. J. Surg., 205, 220, 10.1016/j.amjsurg.2012.05.028 · DOI
  37. Desai, 2016, Open repair of large abdominal wall hernias with and without components separation; an analysis from the ACS-NSQIP database, Ann Med Surg (Lond)., 7, 14, 10.1016/j.amsu.2016.02.026 · doi:10.1016/j.amsu.2016.02.026
  38. Seiler, 2009, Interrupted or continuous slowly absorbable sutures for closure of primary elective midline abdominal incisions: a multicenter randomized trial (INSECT: ISRCTN24023541), Ann. Surg., 249, 576, 10.1097/SLA.0b013e31819ec6c8 · DOI · Paper page

Cited by

See all 30

Metadata

Authors
van Rooijen, M. M., Jairam, A. P., Tollens, T., Jørgensen, L. N., de Vries Reilingh, T. S., Piessen, G., Köckerling, F., Miserez, M., Windsor, A. C., Berrevoet, F., Fortelny, R. H., Dousset, B., Woeste, G., van Westreenen, H. L., Gossetti, F., Lange, J. F., Tetteroo, G. W., Koch, A., Kroese, L. F., & Jeekel, J.
Venue
International Journal of Surgery
Published
2020-11
Volume
83
Pages
31-36
ISSN
1743-9191
Cited by
30
References
1
Language
en
Licence
Funders
Davol Inc

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.