Machine Learning Approach to Detect Cardiac Arrhythmias in ECG Signals: A Survey
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Abstract Cardiac arrhythmia is a condition when the heart rate is irregular either the beat is too slow or too fast. It occurs due to improper electrical impulses that coordinates the heart beats. Sudden cardiac death may occurs due to some dangerous arrhythmias conditions. Hence the main objective of the electrocardiogram (ECG) analysis is to detect the life-threatening arrhythmias accurately for appropriate treatment in order to save life. Since the last decades, several methods were reported for automatic ECG beat classifications. In this work, we present a systematic review of the current state-of-the-art methods used to detect cardiac arrhythmia using on ECG signals. It includes the signal decomposition, feature extraction and machine learning approaches used for automatic detection and decision making process. The articles covers the pre-processing, detection of QRS complex, feature extraction and classification of ECG beats. Based on the past studies, it is understood that the automated approach using computer-aided decision making process is highly required for real-time detection of cardiac arrhythmias. The advantages and limitations of different methods are discussed and also the future scopes is highlighted in the process of effective detection of cardiac arrhythmias. This study could be beneficial for researchers to analyze the existing state-of-art techniques used in detection of arrhythmia conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
Cardiovascular risk and events in 17 low-, middle-, and high-income countries
Yusuf, S., Rangarajan, S., Teo, K., Islam, S., Li, W., Liu, L., Bo, J., Lou, Q., Lu, F., Liu, T., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311890 · Cited by 983
ECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Denoising of ECG signals based on noise reduction algorithms in EMD and wavelet domains
Kabir, M. A., & Shahnaz, C. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.11.003 · Cited by 444
Mechanisms of cardiac arrhythmias
Tse, G. (2016) · Journal of Arrhythmia · doi:10.1016/j.joa.2015.11.003 · Cited by 269
Metadata
- Authors
- Sahoo, S., Dash, M., Behera, S., & Sabut, S.
- Venue
- IRBM
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 41
- Issue
- 4
- Pages
- 185-194
- ISSN
- 1876-0988 (ISSN-L)
- 1959-0318
- OpenAlex
- W2997681386
- Cited by
- 197
- References
- 7
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Machine Learning Approach to Detect Cardiac Arrhythmias in ECG Signals: A Survey. https://app.cochat.ai/papers/10.1016/j.irbm.2019.12.001
- The paper
- Sahoo, S., Dash, M., Behera, S., & Sabut, S. (2020). Machine Learning Approach to Detect Cardiac Arrhythmias in ECG Signals: A Survey. IRBM. https://doi.org/10.1016/j.irbm.2019.12.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.