Automated Echocardiographic Detection of Heart Failure With Preserved Ejection Fraction Using Artificial Intelligence
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background: Detection of heart failure with preserved ejection fraction (HFpEF) involves integration of multiple imaging and clinical features which are often discordant or indeterminate. Objectives: The authors applied artificial intelligence (AI) to analyze a single apical 4-chamber transthoracic echocardiogram video clip to detect HFpEF. Methods: A 3-dimensional convolutional neural network was developed and trained on apical 4-chamber video clips to classify patients with HFpEF (diagnosis of heart failure, ejection fraction ≥50%, and echocardiographic evidence of increased filling pressure; cases) vs without HFpEF (ejection fraction ≥50%, no diagnosis of heart failure, normal filling pressure; controls). Model outputs were classified as HFpEF, no HFpEF, or nondiagnostic (high uncertainty). Performance was assessed in an independent multisite data set and compared to previously validated clinical scores. Results: Training and validation included 2,971 cases and 3,785 controls (validation holdout, 16.8% patients), and demonstrated excellent discrimination (area under receiver-operating characteristic curve: 0.97 [95% CI: 0.96-0.97] and 0.95 [95% CI: 0.93-0.96] in training and validation, respectively). In independent testing (646 cases, 638 controls), 94 (7.3%) were nondiagnostic; sensitivity (87.8%; 95% CI: 84.5%-90.9%) and specificity (81.9%; 95% CI: 78.2%-85.6%) were maintained in clinically relevant subgroups, with high repeatability and reproducibility. Of 701 and 776 indeterminate outputs from the Heart Failure Association-Pretest Assessment, Echocardiographic and Natriuretic Peptide Score, Functional Testing (HFA-PEFF), and Final Etiology and Heavy, Hypertensive, Atrial Fibrillation, Pulmonary Hypertension, Elder, and Filling Pressure (H2FPEF) scores, the AI HFpEF model correctly reclassified 73.5% and 73.6%, respectively. During follow-up (median: 2.3 [IQR: 0.5-5.6] years), 444 (34.6%) patients died; mortality was higher in patients classified as HFpEF by AI (HR: 1.9 [95% CI: 1.5-2.4]). Conclusions: An AI HFpEF model based on a single, routinely acquired echocardiographic video demonstrated excellent discrimination of patients with vs without HFpEF, more often than clinical scores, and identified patients with higher mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization
Selvaraju, R. R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., & Batra, D. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.74 · Cited by 24,513
James, S. L., Abate, D., Abate, K. H., Abay, S. M., Abbafati, C., Abbasi, N., Abbastabar, H., Abd-Allah, F., Abdela, J., Abdelalim, A., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)32279-7 · Cited by 13,867
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
Phenomapping for Novel Classification of Heart Failure With Preserved Ejection Fraction
Shah, S. J., Katz, D. H., Selvaraj, S., Burke, M. A., Yancy, C. W., Gheorghiade, M., Bonow, R. O., Huang, C.-C., & Deo, R. C. (2015) · Circulation · doi:10.1161/circulationaha.114.010637 · Cited by 1,157
Vaduganathan, M., Docherty, K. F., Claggett, B. L., Jhund, P. S., de Boer, R. A., Hernandez, A. F., Inzucchi, S. E., Kosiborod, M. N., Lam, C. S. P., Martinez, F., et al. (2022) · The Lancet · doi:10.1016/s0140-6736(22)01429-5 · Cited by 996
Heart Failure With Preserved Ejection Fraction
Borlaug, B. A., Sharma, K., Shah, S. J., & Ho, J. E. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.01.049 · Cited by 742
Patient selection in heart failure with preserved ejection fraction clinical trials
Kelly, J. P., Mentz, R. J., Mebazaa, A., Voors, A. A., Butler, J., Roessig, L., Fiuzat, M., Zannad, F., Pitt, B., O’Connor, C. M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.043 · Cited by 139
Cited by
Nagueh, S. F., Sanborn, D. Y., Oh, J. K., Anderson, B., Billick, K., Derumeaux, G., Klein, A., Koulogiannis, K., Mitchell, C., Shah, A., et al. (2025) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2025.03.011 · Cited by 361
Vision–language foundation model for echocardiogram interpretation
Christensen, M., Vukadinovic, M., Yuan, N., & Ouyang, D. (2024) · Nature Medicine · doi:10.1038/s41591-024-02959-y · Cited by 231
Hong, D., Song, S.-H., Shin, H., Bak, M., Kim, J., Kim, D., Kim, J. Y., Yang, J. H., Park, S.-J., Choi, J.-O., et al. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf080 · Cited by 14
Automated HFrEF Diagnosis Using an Optimized TimeSformer Model in Echocardiography
Petmezas, G., Papageorgiou, V. E., Vassilikos, V., Pagourelias, E., Tachmatzidis, D., Tsaklidis, G., Katsaggelos, A. K., & Maglaveras, N. (2025) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-025-01758-2 · Cited by 3
Metadata
- Authors
- Akerman, A. P., Porumb, M., Scott, C. G., Beqiri, A., Chartsias, A., Ryu, A. J., Hawkes, W., Huntley, G. D., Arystan, A. Z., Kane, G. C., Pislaru, S. V., Lopez-Jimenez, F., Gomez, A., Sarwar, R., O'Driscoll, J., Leeson, P., Upton, R., Woodward, G., & Pellikka, P. A.
- Venue
- JACC: Advances
- Publisher
- Elsevier BV
- Published
- 2023-08
- Volume
- 2
- Issue
- 6
- Pages
- 100452
- ISSN
- 2772-963X (ISSN-L)
- OpenAlex
- W4385335928
- Cited by
- 113
- References
- 8
- FWCI
- 23.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.