CoChat

Noninvasive Detection of Macrophage-Rich Atherosclerotic Plaque in Hyperlipidemic Rabbits Using “Positive Contrast” Magnetic Resonance Imaging

Open access
Korosoglou, Grigorios, Weiss, Robert G., Kedziorek, Dorota A., Walczak, Piotr, Gilson, Wesley D., Schär, Michael, Sosnovik, David E., Kraitchman, Dara L., Boston, Raymond C., Bulte, Jeff W.M., Weissleder, Ralph, Stuber, Matthias · 2008 · Journal of the American College of Cardiology
Cited by 118

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Objectives To identify macrophage-rich atherosclerotic plaque non-invasively by the combined use of systemic administration of superparamagnetic nanoparticles with magnetic resonance imaging (MRI), using a positive contrast off-resonance imaging sequence (Inversion Recovery with ON-resonant water suppression: IRON). Background The sudden rupture of macrophage-rich atherosclerotic plaques can trigger the formation of an occlusive thrombus in coronary vessels, resulting in acute myocardial infarction. Therefore, a noninvasive technique that can identify macrophage-rich plaques and thereby assist with risk stratification of patients with atherosclerosis would be of great potential clinical utility. Methods Experiments were conducted on a clinical 3T MRI scanner in seven heritable hyperlipidemic and four control rabbits. Monocrystalline iron-oxide nanoparticles (MION)-47 were administrated intravenously (two doses of 250μmol Fe/kg), and animals underwent serial IRON-MRI before injection of the nanoparticles and serially after 1, 3 and 6 days. Results After administration of MION-47, a striking signal enhancement was found in areas of plaque only in hyperlipidemic rabbits. The magnitude of enhancement on MR-images had a high correlation with the number of macrophages determined by histology (p<0.001) and allowed for the detection of macrophage-rich plaque with high accuracy (AUC=0.92, SE=0.04, 95% CI=0.84-0.96, p<0.001). No significant signal enhancement was measured in remote areas without plaque by histology and in controls without atherosclerosis. Conclusion IRON-MRI in conjunction with superparamagnetic nanoparticles is a promising approach for the noninvasive evaluation of macrophage-rich, vulnerable plaques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2008.03.063

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 118

Metadata

Authors
Korosoglou, G., Weiss, R. G., Kedziorek, D. A., Walczak, P., Gilson, W. D., Schär, M., Sosnovik, D. E., Kraitchman, D. L., Boston, R. C., Bulte, J. W. M., Weissleder, R., & Stuber, M.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2008-08
Volume
52
Issue
6
Pages
483-491
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2041848158
Cited by
118
References
6
FWCI
12.42
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.