Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 163

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Prediction of Poor Outcome After Transcatheter Aortic Valve Replacement

Open access
Arnold, Suzanne V., Afilalo, Jonathan, Spertus, John A., Tang, Yuanyuan, Baron, Suzanne J., Jones, Philip G., Reardon, Michael J., Yakubov, Steven J., Adams, David H., Cohen, David J. · 2016 · Journal of the American College of Cardiology

Abstract

BACKGROUND A series of models have been developed to identify patients at high risk for poor outcomes after transcatheter aortic valve replacement (TAVR) to help guide treatment choices, offer patients realistic expectations of long-term outcomes, and support decision making. OBJECTIVES We examined the performance of the previously developed TAVR Poor Outcome risk models in an external dataset and explored the incremental contribution of geriatric domains to model performance. METHODS Poor outcome after TAVR was defined as death, poor quality of life (QOL), or decline in QOL, as assessed using the Kansas City Cardiomyopathy Questionnaire. We tested 4 TAVR Poor Outcome risk models: 6-month and 1-year full and clinical (reduced) models. We examined each model’s discrimination and calibration in the CoreValve trial dataset, then tested the incremental contribution of frailty and disability markers to the model’s discrimination using the incremental discrimination index (IDI). RESULTS Among 2,830 patients who underwent TAVR in the CoreValve US Pivotal Extreme and High Risk trials and associated continued access registries, 31.2% experienced a poor outcome at 6 months following TAVR (death: 17.6%; very poor QOL: 11.6%; QOL decline: 2.0%) and 50.8% experienced a poor outcome at 1 year (death: 30.2%; poor QOL: 19.6%; QOL: decline 1.0%). The models demonstrated similar discrimination as in the Placement of Aortic Transcatheter Valves Trial cohorts (c-indexes: 0.637 to 0.665) and excellent calibration. Adding frailty as a syndrome increased the c-indexes by 0.000 to 0.004 (IDI p < 0.01 for all except the 1-year clinical model), with the most important individual components being disability and unintentional weight loss. CONCLUSIONS Although discrimination of the TAVR Poor Outcome risk models was generally moderate, calibration was excellent among patients with different risk profiles and treated with a different TAVR device. These findings demonstrated the value of these models for individualizing outcome predictions in high-risk patients undergoing TAVR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2016.07.762

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 163

Metadata

Authors
Arnold, S. V., Afilalo, J., Spertus, J. A., Tang, Y., Baron, S. J., Jones, P. G., Reardon, M. J., Yakubov, S. J., Adams, D. H., & Cohen, D. J.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2016-10
Volume
68
Issue
17
Pages
1868-1877
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2534605893
Cited by
163
References
12
FWCI
16.19
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.