Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 310

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

EUropean real-world outcomes with Pulsed field ablatiOn in patients with symptomatic atRIAl fibrillation: lessons from the multi-centre EU-PORIA registry

Open access
Schmidt, Boris, Bordignon, Stefano, Neven, Kars, Reichlin, Tobias, Blaauw, Yuri, Hansen, Jim, Adelino, Raquel, Ouss, Alexandre, Füting, Anna, Roten, Laurent, Mulder, Bart A, Ruwald, Martin H, Mené, Roberto, van der Voort, Pepijn, Reinsch, Nico, Kueffer, Thomas, Boveda, Serge, Albrecht, Elizabeth M, Schneider, Christopher W, Chun, Kyoung Ryul Julian·2023·Europace

Abstract

Aims: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. Methods and results: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40–87) and 14 (9–21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323–386) days, the Kaplan–Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. Conclusion: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euad185

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 310

Metadata

Authors
Schmidt, B., Bordignon, S., Neven, K., Reichlin, T., Blaauw, Y., Hansen, J., Adelino, R., Ouss, A., Füting, A., Roten, L., Mulder, B. A., Ruwald, M. H., Mené, R., van der Voort, P., Reinsch, N., Kueffer, T., Boveda, S., Albrecht, E. M., Schneider, C. W., & Chun, K. R. J.
Venue
Europace
Published
2023-06-28
Volume
25
Issue
7
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W4382502299
Cited by
310
References
26
FWCI
54.53
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: EUropean real-world outcomes with Pulsed field ablatiOn in patients with symptomatic atRIAl fibrillation: lessons from the multi-centre EU-PORIA registry. https://app.cochat.ai/papers/10.1093/europace/euad185
The paper
Schmidt, B., Bordignon, S., Neven, K., Reichlin, T., Blaauw, Y., Hansen, J., Adelino, R., Ouss, A., Füting, A., Roten, L., Mulder, B. A., Ruwald, M. H., Mené, R., van der Voort, P., Reinsch, N., Kueffer, T., Boveda, S., Albrecht, E. M., Schneider, C. W., & Chun, K. R. J. (2023). EUropean real-world outcomes with Pulsed field ablatiOn in patients with symptomatic atRIAl fibrillation: lessons from the multi-centre EU-PORIA registry. Europace. https://doi.org/10.1093/europace/euad185

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.