The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
The WATCH AF Trial: SmartWATCHes for Detection of Atrial Fibrillation
Open accessAbstract
Objectives The WATCH AF (SmartWATCHes for Detection of Atrial Fibrillation) trial compared the diagnostic accuracy to detect atrial fibrillation (AF) by a smartwatch-based algorithm using photoplethysmographic (PPG) signals with cardiologists' diagnosis by electrocardiography (ECG).Background Timely detection of AF is crucial for stroke prevention.Methods In this prospective, 2-center, case-control trial, a PPG pulse wave recording using a commercially available smartwatch was obtained along with Internet-enabled mobile ECG in 672 hospitalized subjects. PPG recordings were analyzed by a novel automated algorithm. Cardiologists' diagnoses were available for 650 subjects, although 142 (21.8%) datasets were not suitable for PPG analysis, among them 101 (15.1%) that were also not interpretable by the automated Internet-enabled mobile ECG algorithm, resulting in a sample size of 508 subjects (mean age 76.4 years, 225 women, 237 with AF) for the main analyses.Results For the PPG algorithm, we found a sensitivity of 93.7% (95% confidence interval [CI]: 89.8% to 96.4%), a specificity of 98.2% (95% CI: 95.8% to 99.4%), and 96.1% accuracy (95% CI: 94.0% to 97.5%) to detect AF.Conclusions The results of the WATCH AF trial suggest that detection of AF using a commercially available smartwatch is in principle feasible, with very high diagnostic accuracy. Applicability of the tested algorithm is currently limited by a high dropout rate as a result of insufficient signal quality. Thus, achieving sufficient signal quality remains challenging, but real-time signal quality checks are expected to improve signal quality. Whether smartwatches may be useful complementary tools for convenient long-term AF screening in selected at-risk patients must be evaluated in larger population-based samples. (SmartWATCHes for Detection of Atrial Fibrillation [WATCH AF]:; NCT02956343).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“but the reliability of such tools is limited by the presence of noise in data collected from wearable and handheld devices12,13.”
From Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices (2023) · cites this paper as [12]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“with a wearable device-based atrial fibrillation screening study disqualifying 22% of patients due to insufficient signal quality12.”
From Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices (2023) · cites this paper as [12]
In the citing paper
“A common way to deal with artifact-corrupted PPGs, and thus improve the reliability of arrhythmia detectors, is to exclude segments of poor signal quality [10,27,28] as well as accelerometer-identified motion [11][12][13][27][28][29][30].”
From Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias (2021) · cites this paper as [28]
In the citing paper
“The potential utility of wrist-worn PPG devices for detecting possible AF has been assessed in recent studies”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [198]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,439
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Kernan, W. N., Ovbiagele, B., Black, H. R., Bravata, D. M., Chimowitz, M. I., Ezekowitz, M. D., Fang, M. C., Fisher, M., Furie, K. L., Heck, D. V., et al. (2014) · Stroke · doi:10.1161/str.0000000000000024 · Cited by 5,170
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Statistics Notes: Diagnostic tests 2: predictive values
Altman, D. G., & Bland, J. M. (1994) · BMJ · doi:10.1136/bmj.309.6947.102 · Cited by 1,711
Atrial fibrillation in patients with cryptogenic stroke
Gladstone, D. J., Spring, M., Dorian, P., Panzov, V., Thorpe, K. E., Hall, J., Vaid, H., O'Donnell, M., Laupacis, A., Côté, R., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311376 · Cited by 1,276
Measures of Diagnostic Accuracy: Basic Definitions.
Šimundić, A.-M. (2009) · PubMed Central · Cited by 1,268
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–200 of 245
Consumer-Led Screening for Atrial Fibrillation
Guo, Y., Zhang, H., & Lip, G. Y. H. (2022) · JACC Asia · doi:10.1016/j.jacasi.2022.07.006 · Cited by 15
“1% for AF detection among subjects, with a mean age 76 years.(14) Thus, affordable, easyfor-use, consumer-led PPG-based smartwear can be a good screening tool, not only for an elderly population with comorbidities, but also for mass screening in the low-risk general population, with more prolonged, frequent monitoring.”
BackgroundConsumer-grade wearable cardiac monitors: What they do well, and what needs work
Mohamoud, A. A., Jensen, J. C., & BUDA, K. G. (2024) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.91a.23030 · Cited by 15
“However, longer sampling frequency did not improve atrial fi brillation detection in the Watch AF trial (Smartwatches for the Detection of Atrial Fibrillation), 22 which compared a smartwatch-based algo-rithm using PPG signals vs a single-lead handheld ECG analyzed by 2 cardiologists.”
MethodZarak, M. S., Khan, S. A., Majeed, H., Yasinzai, A. Q. K., Hamzazai, W., Chung, D., Koshkarian, G., & Fleming, K. S. (2024) · International Journal of Arrhythmia · doi:10.1186/s42444-024-00118-5 · Cited by 16
Smart Wearables in Pediatric Heart Health
Behere, S. P., & Janson, C. M. (2022) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2022.08.009 · Cited by 12
Sohn, J., Shin, H., Lee, J., & Kim, H. C. (2023) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-023-00156-z · Cited by 11
“Hence, wearable devices that measure photoplethysmography (PPG) have been shown to have the potential to detect AF [ 5 – 7] because the pulsatile component of the PPG waveform can extract heart rate, among other cardiovascular parameters [ 8 ].”
BackgroundMonteiro, R., Rabello, G. D. C. M., Moreno, C. R., Moitinho, M. S., Pires, F. A., Samesina, N., César, L. A. M., Tarasoutchi, F., Fernandes, F., Martins, P., et al. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1443998 · Cited by 11
Luo, D. Y., Zhang, Z. W., Sibomana, O., & Salomon, I. (2025) · Annals of Medicine and Surgery · doi:10.1097/ms9.0000000000003155 · Cited by 11
“One study [53] (4”
InfluentialUse of a Smartwatch for Assessment of the QT Interval in Outpatients with Coronavirus Disease 2019
Chinitz, J. S., Goyal, R., Morales, D. C., Harding, M., Selim, S., & Epstein, L. M. (2020) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2020.1100904 · Cited by 11
Does asymptomatic atrial fibrillation exist?
Carneiro, H. A., & Knight, B. P. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16108 · Cited by 11
“95,96 The burden of AF has more recently been appreciated as a factor influencing the impact of AF on clinical endpoints.”
BackgroundFerreira, J. P., Cleland, J. G. F., Lam, C. S. P., Anker, S. D., Mehra, M. R., van Veldhuisen, D. J., Byra, W. M., Police, D. A. L., Greenberg, B., & Zannad, F. M. (2021) · Clinical Research in Cardiology · doi:10.1007/s00392-021-01891-2 · Cited by 10
A review of patient-led data acquisition for atrial fibrillation detection to prevent stroke
Kareem, M., Lei, N., Ali, A., Ciaccio, E. J., Acharya, U. R., & Faust, O. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102818 · Cited by 10
Samol, A., Bischof, K., Luani, B., Pascut, D., Wiemer, M., & Kaese, S. (2019) · Journal of Visualized Experiments · doi:10.3791/60715 · Cited by 9
Merschel, S., & Reinhardt, L. (2022) · JMIR Formative Research · doi:10.2196/29479 · Cited by 8
“For 1-minute measurements using wrist-worn devices in a controlled laboratory setting (relaxed sitting position with both arms resting on a firm surface), both algorithms (PHA and FibriCheck) demonstrated sensitivity and specificity comparable to smartphone analyses [16,17].”
MethodOver- and undersensing—pitfalls of arrhythmia detection with implantable devices and wearables
Sperzel, J., Hamm, C. W., & Hain, A. (2020) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-020-00710-x · Cited by 9
Akram, M. S., Varma, B. S., Javed, A., Harkin, J., & Finlay, D. (2025) · Journal of Systems Architecture · doi:10.1016/j.sysarc.2025.103587 · Cited by 12
Advances and Challenges in Wearable Sensors for Health Monitoring
Brazaca, L. C., Lozano, A. M., Mayol, B., Scheidt, D. T., Fazio, D. D., Kim, E., Maroli, G., Rosati, G., Ates, H. C., Wang, H., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c04520 · Cited by 9
AI can now identify atrial fibrillation through sinus rhythm
Hendriks, J., & Fabritz, L. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31719-2 · Cited by 8
Huynh, P. P., Shan, R., Osuji, N., Ding, J., Isakadze, N., Marvel, F. A., Sharma, G. V., & Martin, S. S. (2020) · JMIR Cardio · doi:10.2196/18050 · Cited by 8
“Although several studies have evaluated the validity of smart watch algorithms to detect AF in healthy adults without cardiovascular disease [3,6,23], while some have assessed HR accuracy in wrist-worn monitors among healthy participants or patients with cardiovascular disease [24], our work adds to the body of resear…”
The Role of Artificial Intelligence in Arrhythmia Monitoring
Siontis, K. C., & Friedman, P. A. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.011 · Cited by 8
AI and the cardiologist: when mind, heart and machine unite
D’Costa, A., & Zatale, A. (2021) · Open Heart · doi:10.1136/openhrt-2021-001874 · Cited by 10
Basem, J. I., Mani, R., Sun, S., Gilotra, K., Dianati‐Maleki, N., & Dashti, R. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1525966 · Cited by 8
Khundaqji, H., Hing, W. A., Furness, J. W., & Climstein, M. (2021) · PeerJ · doi:10.7717/peerj.12598 · Cited by 7
Digital wearable devices in cardiac rehabilitation: patient need and satisfaction. Literature Review
Павловна, Л. Н., & Kharytonov, S. V. (2022) · Cardiosomatics · doi:10.17816/22217185.2022.1.201471 · Cited by 10
Smartphone and new tools for atrial fibrillation diagnosis: evidence for clinical applicability
PAPACCIOLI, G., BASSI, G., Cecilia, L. U. G. I., Parente, E., D’ANDREA, A., PROIETTI, R., Imbalzano, E., TURKI, A. A., & Russo, V. (2022) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.22.05841-0 · Cited by 7
Fabritz, L., Connolly, D. L., Czarnecki, E., Dudek, D., Złahoda-Huzior, A., Guasch, E., Haase, D., Huebner, T. A., Jolly, K. B., Kirchhof, P. F., et al. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.839202 · Cited by 7
Is machine learning the future for atrial fibrillation screening?
Sivanandarajah, P., Wu, H., Bajaj, N., Khan, S. N., & Ng, F. S. (2022) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2022.04.001 · Cited by 8
eHealth – Smart Devices revolutionieren die Kardiologie
Ledwoch, J., & Duncker, D. (2020) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-020-00700-z · Cited by 7
Introduction of Wearable Device in Cardiovascular Field for Monitoring Arrhythmia
Kim, N. H., & Ko, J. S. (2021) · Chonnam Medical Journal · doi:10.4068/cmj.2021.57.1.1 · Cited by 7
Kalla, M., Fabritz, L., & Kirchhof, P. F. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.11.018 · Cited by 6
“(5) report a prospective, case-control trial of wearable ECG monitoring technology utilizing photoplethysmography (PPG) compared with a patient-operated ECG device (Kardia; AliveCor, Mountain View, California).”
BackgroundMethodSantala, O. E., Lipponen, J. A., Jäntti, H., Rissanen, T. T., Tarvainen, M. P., Väliaho, E., Rantula, O., Naukkarinen, N. S., Hartikainen, J. E. K., Martikainen, T. J., et al. (2023) · Cardiology in Review · doi:10.1097/crd.0000000000000526 · Cited by 10
Barata, F., Shim, J., Wu, F., Langer, P., & Fleisch, E. (2024) · JAMIA Open · doi:10.1093/jamiaopen/ooae027 · Cited by 6
“18,19 Digital biomarkers, however, are also employed in the realm of secondary prevention, 20–22 which involves the early detection of diseases.”
BackgroundDing, X., Wang, Y., Hao, Y., Lv, Y., Chen, R., & Yan, H. (2021) · Computational and Mathematical Methods in Medicine · doi:10.1155/2021/5597559 · Cited by 6
Adasuriya, G., & Haldar, S. (2022) · European Journal of Arrhythmia & Electrophysiology · doi:10.17925/ejae.2022.8.1.7 · Cited by 5
Mahajan, S., Garg, S., Sharma, R., Singh, Y., Chandola, N., Bhatia, T., & Bansal, B. (2023) · International Journal of Research in Medical Sciences · doi:10.18203/2320-6012.ijrms20230855 · Cited by 5
Doležel, M., & Smutný, Z. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18137147 · Cited by 6
“This was due to recent discussions regarding the potential of using consumer electronics for atrial fibrillation screening and recording of single-lead ECG, both worldwide [37,38] and locally.”
BackgroundReprint of: An embedded lightweight SSVEP-BCI electric wheelchair with hybrid stimulator
Na, R., Hu, C., Sun, Y. Z., Wang, S., Zhang, S., Han, M., Yin, W., Zhang, J., Chen, X., & Zheng, D. (2022) · Digital Signal Processing · doi:10.1016/j.dsp.2022.103573 · Cited by 6
Photoplethysmography-Based Smart Devices for Detection of Atrial Fibrillation
Sijerčić, A., & Tahirović, E. (2022) · Texas Heart Institute Journal · doi:10.14503/thij-21-7564 · Cited by 6
Characterization of Atrial Fibrillation Episode Patterns: A Comparative Study
Butkuvienė, M., Petrėnas, A., Martín-Yebra, A., Marozas, V., & Sörnmo, L. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3293252 · Cited by 5
“Commonly, studies evaluating AF detector performance tend to exclude poor quality segments [35], [36], [37], thus exag-gerating performance.”
BackgroundFrom Research to Practice: The Future of Cardiovascular Care
Manoria, P. C. (2025) · Cureus · doi:10.7759/cureus.84473 · Cited by 7
Digital Technologies in Heart Failure Management
Shah, M., Zimmer, R. J., Kollefrath, M., & Khandwalla, R. M. (2020) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-020-00643-7 · Cited by 5
“Although these devices were highly specific and sensitive in detecting atrial fibrillation, a large percentage (> 20%) of rhythms were deemed non-analyzable in trials [26, 27], and therefore, accuracy is a major concern.”
BackgroundImproved Atrial Fibrillation Detection using CNN-LSTM
Tallapragada, V. V. S., Reddy, D. V., Varma, K. N. V. S., & Sarma, G. S. (2022) · International Conference on Trends in Electronics and Informatics (ICOEI) · doi:10.1109/icoei53556.2022.9776825 · Cited by 5
An augmented reality–based method to assess precordial electrocardiogram leads: a feasibility trial
Serfözö, P. D., Sandkühler, R., Blümke, B., Matthisson, E., Meier, J., Odermatt, J., Badertscher, P., Sticherling, C., Strebel, I., Cattin, P. C., et al. (2023) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad046 · Cited by 5
Varma, N., Cygankiewicz, I., & Turakhia, M. P. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4420 · Cited by 7
Atrial fibrillation and sport: need for monitoring
Bressi, E., REBECCHI, M., SGUEGLIA, M., Crescenzi, C., PANATTONI, G., MARTINO, A., CASALESE, A., SANGIORGI, C., POLITANO, A., CICOGNA, F., et al. (2022) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.22.05842-2 · Cited by 5
A Smartwatch to Identify Atrial Fibrillation
Turakhia, M. P., Desai, M., & Perez, M. V. (2020) · New England Journal of Medicine · doi:10.1056/nejmc1916858 · Cited by 5
Barbosa, I. O. F., de Oliveira, B. C., Santos, C. K. M., Miranda, M. C. R., Barbosa, G. A., & Menezes, A. D. S. (2025) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2024.0579 · Cited by 7
Ma, Z., Caldwell, R., Attia, Z. I., Friedman, P. A., Lerman, A., Ng, C. T., & Herrmann, J. (2026) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2026.01.006 · Cited by 4
Abdelhamid, K., Reissenberger, P., Piper, D., Koenig, N., Hölz, B., Schlaepfer, J., Gysler, S., McCullough, H., Ramin-Wright, S., Gabathuler, A.-L., et al. (2025) · Diagnostics · doi:10.3390/diagnostics15101233 · Cited by 5
“The Preventicus Heartbeats Algorithm, used in this study, has been shown to have a sensitivity of 93.7% and a specificity of 98.2% [13], making it an ideal choice due to its excellent overall diagnostic performance across all key parameters.”
InfluentialMathew, J., Mehawej, J., Wang, Z., Orwig, T. A., Ding, E., Filippaios, A., Naeem, S. S., Otabil, E. M., Hamel, A. P., Noorishirazi, K., et al. (2024) · 老年心脏病学杂志:英文版 · doi:10.26599/1671-5411.2024.03.005 · Cited by 5
Ochoa, G. F. T., Clavijo, P. E. C., Tonato, J. L. M., Guartatanga, P. G. P., Vela, M. P. M., Nuñez, F. I. N., Andino, A. V. V., & Ponce, N. R. P. (2024) · Salud Ciencia y Tecnología · doi:10.56294/saludcyt2024.962 · Cited by 4
Toward Patient-Centered AI Fact Labels: Leveraging Extrinsic Trust Cues
Yoo, D. W., Stroud, A. M., Zhu, X., Miller, J. E., & Barry, B. A. (2025) · Designing Interactive Systems Conference · doi:10.1145/3715336.3735758 · Cited by 7
“The written vignettes were shared as text with the participants, except in one case where a participant struggled to read the text due to technical issue; in this instance, it was read aloud.”
Osca, J., de Francisco, M. T. I., Pérez, Ó. C., de Carranza, M. J. S.-T., Rubio, J. A., Palop, C. P., Vidal, J., & Martínez‐Dolz, L. (2020) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2020.05.034 · Cited by 4
Александрович, Ф. А., Gorshkov, A. Y., Korolev, A. I., & Drapkina, O. M. (2022) · CARDIOVASCULAR THERAPY AND PREVENTION · doi:10.15829/1728-8800-2022-3298 · Cited by 4
Lohrmann, G. M., & PASSMAN, R. S. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14847 · Cited by 4
Salunke, D., Mujawar, M. S., Gajare, A., Deshmukh, P. M., Mulani, D., & Kadam, M. (2024) · IEEE World Conference on Applied Intelligence and Computing (AIC) · doi:10.1109/aic61668.2024.10731134 · Cited by 3
“[17] PPG algorithm with ECG 95 % Specific ECG smart-watch is required for the detection.”
MethodRantula, O., Lipponen, J. A., Halonen, J., Jäntti, H., Rissanen, T. T., Naukkarinen, N. S., Väliaho, E., Santala, O. E., Sedha, J., Martikainen, T. J., et al. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf055 · Cited by 4
“,21–26 Similar to our study, in a specific part of the study by Bonomi et al ., wristband PPG was captured during elective CV in stationary patients, and the reported sensitivities (97–98”
Vaishnav, A. G., & Desai, S. (2025) · Annals of Indian Academy of Neurology · doi:10.4103/aian.aian_156_25 · Cited by 3
D’Ancona, G., Ketterer, U., Kische, S., Murero, M., Feickert, S., Ortak, J., Öner, A. Ö., & İnce, H. (2020) · Future Cardiology · doi:10.2217/fca-2019-0086 · Cited by 4
Vorhofflimmerndiagnostik mittels EKG-fähiger Smartwatches
Haverkamp, W., Göing, O., Anker, M. S., & Anker, S. D. (2021) · Der Nervenarzt · doi:10.1007/s00115-021-01124-x · Cited by 3
Zinzuwadia, A. N., Goldberg, J. M., Hanson, M. A., & Wessler, J. D. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-15980-0.00004-1 · Cited by 3
Zenzes, M., Seba, P., & Portocarerro, B. (2023) · Journal of Medical Case Reports · doi:10.1186/s13256-023-03806-3 · Cited by 3
“8% of the data was not interpretable due to poor signal quality [5].”
BackgroundNoordman, A. B. P., Rienstra, M., Blaauw, Y., Tieleman, R. G., & Maass, A. H. (2023) · Heart Rhythm O2 · doi:10.1016/j.hroo.2023.11.004 · Cited by 3
Nardini, S. G., Corbanese, U., Visconti, A., Mule, J. D., Sanguinetti, C. M., & Benedetto, F. D. (2023) · Multidisciplinary Respiratory Medicine · doi:10.4081/mrm.2023.922 · Cited by 3
Wearable health monitoring: wave of the future or waste of time?
Hudock, N. L., Hughes, H. M., Shaheen, N., Ramadan, A., Parikh, K., Anamika, F., & Jain, R. (2024) · Global Cardiology Science and Practice · doi:10.21542/gcsp.2024.21 · Cited by 5
“The Samsung watch was found to be 94% sensitive and 98% specific for detecting AF 32 .”
BackgroundEerdekens, R., Zelis, J. M., ter Horst, H., Crooijmans, C., Veer, M. V. ’., Keulards, D. C. J., Kelm, M., Archer, G. T., Kühne, T., Brueren, G. R. G., et al. (2024) · JMIR mhealth and uhealth · doi:10.2196/53964 · Cited by 3
“Smart phones and health watches, in particular, have found their way into the clinic [9].”
BackgroundScreening for Atrial Fibrillation: Risks, Benefits, and Implications On Future Clinical Practice
Ilyas, M. H., Sharih, A. M., Jido, J. T., Ali, A. R. Z., Khoshnaghsh, A., Nadeem, M., & Zahra, S. A. (2024) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-024-01047-1 · Cited by 3
“Although limited in numbers, some studies have demonstrated a high diagnostic accuracy for AF using PPG technology, e.g., smart watches [77–79].”
Eerikäinen, L. M., Bonomi, A., Schipper, F., Dekker, L., Vullings, R., de Morree, H. M., & Aarts, R. M. (2019) · TU/e Research Portal · doi:10.23919/cinc49843.2019.9005802 · Cited by 3
Eerikäinen, L. M., Bonomi, A., Schipper, F., Dekker, L., Vullings, R., de Morree, H. M., & Aarts, R. M. (2019) · Computing in cardiology · doi:10.22489/cinc.2019.086 · Cited by 3
Long term effect of vasectomy on pituitary-gonadal axis.
Devi, P. K., Joshi, U. M., Sb, M., Naik, V. K., Ps, S., & Sheth, A. R. (1977) · PubMed · Cited by 3
Saint‐Lary, L., Pinel, B., Panh, L., Jimenez, G., Geffrelot, J., Kirova, Y., Camilleri, J., Broggio, D., Bernier, M., Mandin, C., et al. (2025) · JMIR Research Protocols · doi:10.2196/67875 · Cited by 2
“ECG smartwatches for the screening of AF has been demonstrated in several studies (sensitivity 55%-97.3%, specificity 60%-98.2% [ 31,34-36]), in particular for silent or paroxysmal AF, by measuring continuous cardiac frequency and SL-ECG [37-39].”
InfluentialBun, S., Taghji, P., & Deharo, J. (2021) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2020.12.005 · Cited by 2
Liran, O., Banon, T., & Grossman, A. (2021) · European Journal of General Practice · doi:10.1080/13814788.2021.1947237 · Cited by 2
Zaydi, H., & Bakkoury, Z. (2023) · International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME) · doi:10.1109/iceccme57830.2023.10253335 · Cited by 2
“Connected watches have been used in clinical settings for specific diseases such as AF [5], tachycardia [6], and all arrhythmias.”
MethodDigitale Kompetenzen in der Rhythmologie
Emrani, M., & Zink, M. D. (2024) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-024-00990-7 · Cited by 2
Oxygen saturation measurement in cyanotic heart disease with the Apple watch
Weis, A., Leroy, M., Jux, C., Rupp, S., & Backhoff, D. (2024) · Cardiology in the Young · doi:10.1017/s1047951124025216 · Cited by 2
Kitajima, H., Takeda, K., Ishizawa, M., Aihara, K., & Minamino, T. (2025) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0212068 · Cited by 2
Alpar, S., & Tatlıparmak, A. C. (2025) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.05.037 · Cited by 2
Digital health solutions in the screening of subclinical atrial fibrillation
König, S., Bollmann, A., & Hindricks, G. (2021) · Herz · doi:10.1007/s00059-021-05041-2 · Cited by 2
Osca, J., de Francisco, M. T. I., Pérez, Ó. C., de Carranza, M. J. S.-T., Rubio, J. A., Palop, C. P., Vidal, J., & Martínez‐Dolz, L. (2020) · Revista Española de Cardiología · doi:10.1016/j.recesp.2020.05.006 · Cited by 2
Place de la médecine connectée dans la détection de la fibrillation atriale
Saoudi, N. C., Latcu, G., Enache, B., Yaïci, K., Zarqane, N., Benhenda, N., & Pathak, A. (2021) · Bulletin de l Académie Nationale de Médecine · doi:10.1016/j.banm.2021.09.014 · Cited by 2
Automated Indicator of Atrial Fibrillations Risk Using Machine Learning
Almazrouei, M., & Al-Rajab, M. M. (2021) · International Conference on Computational Science and Computational Intelligence (CSCI) · doi:10.1109/csci54926.2021.00254 · Cited by 2
Design of Health Detection System for Elderly Smart Watch Based on Biosignal Acquisition
Zhu, Z., Wang, P., & Wang, F. (2022) · Journal of Sensors · doi:10.1155/2022/6988001 · Cited by 2
Role of Artificial Intelligence in Biomedical Imaging
Sharma, A., Tripathi, P. M., & Sharma, S. (2023) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-6684-6957-6.ch002 · Cited by 2
The potential for photoplethysmographic (PPG)-based smart devices in atrial fibrillation detection
Harrison, S. L., Lane, D. A., Guo, Y., & Lip, G. Y. H. (2020) · Expert Review of Medical Devices · doi:10.1080/17434440.2020.1740085 · Cited by 2
“Studies have included patients from different settings including hospitals [7,9,11,12], primary care [8] or all adults who own a particular device [10].”
BackgroundMethodInfluentialPenkert, H., Härtl, J., Hapfelmeier, A., Egert-Schwender, S., Heimsch, E., Friedenberg, S., Müller, A., Hahn, F., Martens, E., & Wunderlich, S. (2025) · Frontiers in Neurology · doi:10.3389/fneur.2025.1661087 · Cited by 2
Armas, R. E. D., & Singh, J. P. (2026) · Current Cardiology Reports · doi:10.1007/s11886-026-02358-4 · Cited by 2
Rashid, A. B., Aslam, E., Ashraf, I., Mubeen, T., Mubeen, A., Zakriya, H., & Amjad, M. (2026) · Future Cardiology · doi:10.1080/14796678.2026.2689050 · Cited by 1
Smartwatch helps detects lung cancer: Using personal technology to advance healthcare
Cole, A. P. C., Kar, A. J., Nimako, K., & Smelt, J. (2022) · JRSM Open · doi:10.1177/20542704211068651 · Cited by 1
AI and The Cardiologist-When Mind, Heart and Machine Unite
D’Costa, A., & Zatale, A. (2022) · Communications in computer and information science · doi:10.1007/978-3-030-95502-1_10 · Cited by 1
Smart Watches: Capturing Our Hearts
Higgins John, P., Cerra, Z. A., & Apicella, M. (2022) · Journal of Cardiothoracic Surgery and Therapeutics · doi:10.36959/582/441 · Cited by 1
Pfeiffer, B. F., & de Almeida, C. P. (2022) · Research Society and Development · doi:10.33448/rsd-v11i16.37774 · Cited by 1
Explainable detection of atrial fibrillation using deep convolutional neural network with UCMFB
Rao, B. M., & Kumar, A. (2023) · Multimedia Tools and Applications · doi:10.1007/s11042-023-15123-4 · Cited by 1
“Various techniques for early-stage detection of AF pathology were developed and validated in recent years [17, 32, 47, 52, 57].”
MethodAlzahrani, A., Pyevich, V., & Law, I. H. (2024) · JACC Case Reports · doi:10.1016/j.jaccas.2024.102314 · Cited by 1
Wearables in der Schlaganfallmedizin
Baumgartner, C., Baumgartner, J., Pirker-Kees, A., & Rumpl, E. (2021) · Klinische Neurophysiologie · doi:10.1055/a-1254-9616 · Cited by 1
“[37] Dörr M, Nohturfft V, Brasier N et al.”
BackgroundGardner, L. A., Jones, R., & Motts, M. (2021) · Patient Safety · doi:10.33940/data/2021.12.3 · Cited by 1
A model to enhance the atrial fibrillations’ risk detection using deep learning
Almazrouei, M., & Al-Rajab, M. M. (2022) · Periodicals of Engineering and Natural Sciences (PEN) · doi:10.21533/pen.v10.i3.650 · Cited by 1
Zhang, A. A., Sia, C., & Poh, K. K. (2025) · Singapore Medical Journal · doi:10.4103/singaporemedj.smj-2025-189 · Cited by 1
“[19,20] Mobile devices have also been demonstrated to detect ventricular tachycardia and fibrillation with an accuracy of up to 96.3%.”
InfluentialDörr, M., Nohturfft, V., Brasier, N., Bosshard, E., Djurdjevic, A., Groß, S., Raichle, C. J., Rhinisperger, M., Stöckli, R., & Eckstein, J. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2019.03.001 · Cited by 1
Cardiac Health Assessment using a wearable device before and after TAVIPreprint
Eerdekens, R., Zelis, J. M., ter Horst, H., Crooijmans, C., Veer, M. V. ’., Keulards, D. C. J., Kelm, M., Archer, G. T., Kühne, T., Brueren, G. R. G., et al. (2023) · medRxiv · doi:10.1101/2023.03.22.23287604 · Cited by 1
“Smart phones and health watches, in particular, have found their way into the clinic.(6) These devices can detect atrial fibrillation(7) and predict the wearer’s 5-year risk of dying.”
Screening for atrial fibrillation and treatment with anticoagulant to prevent stroke
Ghazal, F. (2020) · Figshare
Metadata
- Authors
- Dörr, M., Nohturfft, V., Brasier, N., Bosshard, E., Djurdjevic, A., Gross, S., Raichle, C. J., Rhinisperger, M., Stöckli, R., & Eckstein, J.
- Affiliations
- Universitätsmedizin Greifswald (DE)
- University Hospital of Basel (CH)
- Corresponding author
- Dörr, Marcus
- Venue
- JACC. Clinical electrophysiology
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 5
- Issue
- 2
- Pages
- 199-208
- ISSN
- 2405-500X (ISSN-L)
- OpenAlex
- W2902001060
- Cited by
- 245
- References
- 34
- Citations by year
- 2026: 15 · 2025: 21 · 2024: 32 · 2023: 37 · 2022: 45 · 2021: 47 · 2020: 33 · 2019: 14
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- JACC. Clinical electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Universitätsspital Basel
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- atrial fibrillation, smartwatches, photoplethysmography, atrial fibrillation detection, diagnostic accuracy, stroke prevention, hospitalized patients, signal quality
- MeSH terms
- Wearable Electronic Devices, Aged, Aged, 80 and over, Algorithms, Atrial Fibrillation, Electrocardiography, Female, Humans, Male, Prospective Studies, Sensitivity and Specificity, Reproducibility of Results, Case-Control Studies, Photoplethysmography, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review