The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
The WATCH AF Trial: SmartWATCHes for Detection of Atrial Fibrillation
Open accessAbstract
Objectives The WATCH AF (SmartWATCHes for Detection of Atrial Fibrillation) trial compared the diagnostic accuracy to detect atrial fibrillation (AF) by a smartwatch-based algorithm using photoplethysmographic (PPG) signals with cardiologists' diagnosis by electrocardiography (ECG).Background Timely detection of AF is crucial for stroke prevention.Methods In this prospective, 2-center, case-control trial, a PPG pulse wave recording using a commercially available smartwatch was obtained along with Internet-enabled mobile ECG in 672 hospitalized subjects. PPG recordings were analyzed by a novel automated algorithm. Cardiologists' diagnoses were available for 650 subjects, although 142 (21.8%) datasets were not suitable for PPG analysis, among them 101 (15.1%) that were also not interpretable by the automated Internet-enabled mobile ECG algorithm, resulting in a sample size of 508 subjects (mean age 76.4 years, 225 women, 237 with AF) for the main analyses.Results For the PPG algorithm, we found a sensitivity of 93.7% (95% confidence interval [CI]: 89.8% to 96.4%), a specificity of 98.2% (95% CI: 95.8% to 99.4%), and 96.1% accuracy (95% CI: 94.0% to 97.5%) to detect AF.Conclusions The results of the WATCH AF trial suggest that detection of AF using a commercially available smartwatch is in principle feasible, with very high diagnostic accuracy. Applicability of the tested algorithm is currently limited by a high dropout rate as a result of insufficient signal quality. Thus, achieving sufficient signal quality remains challenging, but real-time signal quality checks are expected to improve signal quality. Whether smartwatches may be useful complementary tools for convenient long-term AF screening in selected at-risk patients must be evaluated in larger population-based samples. (SmartWATCHes for Detection of Atrial Fibrillation [WATCH AF]:; NCT02956343).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“but the reliability of such tools is limited by the presence of noise in data collected from wearable and handheld devices12,13.”
From Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices (2023) · cites this paper as [12]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“with a wearable device-based atrial fibrillation screening study disqualifying 22% of patients due to insufficient signal quality12.”
From Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices (2023) · cites this paper as [12]
In the citing paper
“A common way to deal with artifact-corrupted PPGs, and thus improve the reliability of arrhythmia detectors, is to exclude segments of poor signal quality [10,27,28] as well as accelerometer-identified motion [11][12][13][27][28][29][30].”
From Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias (2021) · cites this paper as [28]
In the citing paper
“The potential utility of wrist-worn PPG devices for detecting possible AF has been assessed in recent studies”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [198]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Kernan, W. N., Ovbiagele, B., Black, H. R., Bravata, D. M., Chimowitz, M. I., Ezekowitz, M. D., Fang, M. C., Fisher, M., Furie, K. L., Heck, D. V., et al. (2014) · Stroke · doi:10.1161/str.0000000000000024 · Cited by 5,170
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Statistics Notes: Diagnostic tests 2: predictive values
Altman, D. G., & Bland, J. M. (1994) · BMJ · doi:10.1136/bmj.309.6947.102 · Cited by 1,711
Measures of Diagnostic Accuracy: Basic Definitions.
Šimundić, A.-M. (2009) · PubMed · Cited by 1,360
Atrial fibrillation in patients with cryptogenic stroke
Gladstone, D. J., Spring, M., Dorian, P., Panzov, V., Thorpe, K. E., Hall, J., Vaid, H., O'Donnell, M., Laupacis, A., Côté, R., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311376 · Cited by 1,276
Measures of diagnostic accuracy: basic definitions
Šimundić, A.-M. (2009) · Medical and Biological Sciences · Cited by 1,136
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Screening for Atrial Fibrillation
Freedman, B., Camm, A. J., Calkins, H. G., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 559
Andersson, T., Magnuson, A., Bryngelsson, I., Fröbert, O., Henriksson, K. M., Edvardsson, N. G., & Poçi, D. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs469 · Cited by 450
Smartwatch Algorithm for Automated Detection of Atrial Fibrillation
Bumgarner, J. M., Lambert, C. T., Hussein, A. A., Cantillon, D. J., Baranowski, B., Wolski, K., Lindsay, B. D., Wazni, O. M., & Tarakji, K. G. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.003 · Cited by 446
Hobbs, F., Fitzmaurice, D., Mant, J., Murray, E., Jowett, S., Bryan, S., Raftery, J., Davies, M., & Lip, G. (2005) · Health Technology Assessment · doi:10.3310/hta9400 · Cited by 437
Kishore, A., Vail, A., Majid, A., Dawson, J., Lees, K. R., Tyrrell, P. J., & Smith, C. J. (2014) · Stroke · doi:10.1161/strokeaha.113.003433 · Cited by 374
Wachter, R., Gröschel, K., Gelbrich, G., Hamann, G. F., Kermer, P., Liman, J., Seegers, J., Wasser, K., Schulte, A., Jürries, F., et al. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30002-9 · Cited by 283
McManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Chan, P., Wong, C., Poh, Y. C., Pun, L., Leung, W. W., Wong, Y., Wong, M. M., Poh, M., Chu, D. W., & Siu, C. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.003428 · Cited by 240
Grond, M., Jauss, M., Hamann, G., Stark, E., Veltkamp, R., Nabavi, D., Horn, M., Weimar, C., Köhrmann, M., Wachter, R., et al. (2013) · Stroke · doi:10.1161/strokeaha.113.001884 · Cited by 229
Mairesse, G., Moran, P., van Gelder, I. V., Elsner, C., Rosenqvist, M., Mant, J., Banerjee, A., Gorenek, B., Brachmann, J., Varma, N., et al. (2018) · Europace · doi:10.1093/europace/eux177 · Cited by 191
Brasier, N., Raichle, C. J., Dörr, M., Becke, A., Nohturfft, V., Weber, S., Bulacher, F., Salomon, L., Noah, T., Birkemeyer, R., et al. (2018) · EP Europace · doi:10.1093/europace/euy176 · Cited by 146
Monitoring and detecting atrial fibrillation using wearable technology
Nemati, S., Ghassemi, M. M., Ambai, V., Isakadze, N., Levantsevych, O. M., Shah, A. J., & Clifford, G. D. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591456 · Cited by 144
Smart detection of atrial fibrillation
Krivoshei, L., Weber, S., Burkard, T., Maseli, A., Brasier, N., Kühne, M., Conen, D., Huebner, T. A., Seeck, A., & Eckstein, J. (2016) · EP Europace · doi:10.1093/europace/euw125 · Cited by 114
Vorhofflimmern besser erkennen, hilft Schlaganfälle zu verhindern
(2017) · Fortschritte der Neurologie · Psychiatrie · doi:10.1055/s-0043-106146 · Cited by 113
Taggar, J., Coleman, T. J., Lewis, S., Heneghan, C. J., & Jones, M. (2015) · European Journal of Preventive Cardiology · doi:10.1177/2047487315611347 · Cited by 106
Smart-watches: a potential challenger to the implantable loop recorder?
Carpenter, A., & Frontera, A. (2016) · Europace · doi:10.1093/europace/euv427 · Cited by 86
A prospective study of predictors of prolonged hospital stay and disability after stroke
Spratt, N. J., Wang, Y., Levi, C. R., Ng, K., Evans, M. K., & Fisher, J. (2003) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2002.12.001 · Cited by 85
Koenig, N., Seeck, A., Eckstein, J., Mainka, A., Huebner, T. A., Voss, A., & Weber, S. (2016) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2015.0212 · Cited by 60
Albers, G. W., Bernstein, R. A., Brachmann, J., Camm, A. J., Easton, J. D., Fromm, P., Goto, S., Granger, C. B., Hohnloser, S. H., Hylek, E. M., et al. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.115.002944 · Cited by 54
Berge, T., Lyngbakken, M. N., Ihle‐Hansen, H., Brynildsen, J., Pervez, M. O., Aagaard, E. N., Vigen, T., Kvisvik, B., Christophersen, I. E., Steine, K., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2018-021704 · Cited by 44
Tischer, T. S., SCHNEIDER, R., Lauschke, J., Neßelmann, C., Klemm, A. B., Diedrich, D., Kundt, G., & Bänsch, D. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12470 · Cited by 34
Lau, C., Siu, C.-W., Yiu, K., Lee, K. L., Chan, Y., & Tse, H. (2015) · EP Europace · doi:10.1093/europace/euv235 · Cited by 23
Flagged first, then by citations
Cited by
Sorted by citations
Manickam, P., Mariappan, S. A., Murugesan, S. M., Hansda, S., Kaushik, A. K., Shinde, R. B., & Thipperudraswamy, S. P. (2022) · Biosensors · doi:10.3390/bios12080562 · Cited by 717
Armoundas, A. A., Narayan, S. M., Arnett, D. K., Spector-Bagdady, K., Bennett, D. A., Celi, L. A., Friedman, P. A., Gollob, M. H., Hall, J. L., Kwitek, A. E., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001201 · Cited by 347
Machine learning in clinical decision making
Adlung, L., Cohen, Y., Mor, U., & Elinav, E. (2021) · Med · doi:10.1016/j.medj.2021.04.006 · Cited by 321
“Sucha frameworkhasbeen shown toprovidebeneficial predictive values in a fewproof-ofconcept studies.(173,174)One studyenrolled9,750participants, 347ofwhichwith atrial fibrillation (AF).”
BackgroundHow to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
“The potential utility of wrist-worn PPG devices for detecting possible AF has been assessed in recent studies [197], [198].”
Metadata
- Authors
- Dörr, M., Nohturfft, V., Brasier, N., Bosshard, E., Djurdjevic, A., Gross, S., Raichle, C. J., Rhinisperger, M., Stöckli, R., & Eckstein, J.
- Affiliations
- Universitätsmedizin Greifswald (DE)
- University Hospital of Basel (CH)
- Corresponding author
- Dörr, Marcus
- Venue
- JACC. Clinical electrophysiology
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 5
- Issue
- 2
- Pages
- 199-208
- ISSN
- 2405-500X (ISSN-L)
- OpenAlex
- W2902001060
- Cited by
- 245
- References
- 34
- Citations by year
- 2026: 15 · 2025: 21 · 2024: 32 · 2023: 37 · 2022: 45 · 2021: 47 · 2020: 33 · 2019: 14
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- JACC. Clinical electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Universitätsspital Basel
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- atrial fibrillation, smartwatches, photoplethysmography, atrial fibrillation detection, diagnostic accuracy, stroke prevention, hospitalized patients, signal quality
- MeSH terms
- Wearable Electronic Devices, Aged, Aged, 80 and over, Algorithms, Atrial Fibrillation, Electrocardiography, Female, Humans, Male, Prospective Studies, Sensitivity and Specificity, Reproducibility of Results, Case-Control Studies, Photoplethysmography, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review