Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Inconsistent Performance of Deep Learning Models on Mammogram Classification

Open access
Wang, Xiaoqin, Liang, Gongbo, Zhang, Yu, Blanton, Hunter, Bessinger, Zachary, Jacobs, Nathan · 2020 · Journal of the American College of Radiology

Abstract

OBJECTIVES Performance of recently developed deep learning models for image classification surpasses that of radiologists. However, there are questions about model performance consistency and generalization in unseen external data. The purpose of this study is to determine if the high performance of deep learning on mammograms can be transferred to external data with a different data distribution. MATERIALS AND METHODS Six deep learning models (three published models with high performance and three models designed by us) were evaluated on four different mammogram data sets, including three public (Digital Database for Screening Mammography, INbreast, and Mammographic Image Analysis Society) and one private data set (UKy). The models were trained and validated on either Digital Database for Screening Mammography alone or a combined data set that included Digital Database for Screening Mammography. The models were then tested on the three external data sets. The area under the receiver operating characteristic curve was used to evaluate model performance. RESULTS The three published models reported validation area under the receiver operating characteristic curve scores between 0.88 and 0.95 on the validation data set. Our models achieved between 0.71 (95% confidence interval [CI]: 0.70-0.72) and 0.79 (95% CI: 0.78-0.80) area under the receiver operating characteristic curve on the same validation data set. However, the same evaluation criteria of all six models on the three external test data sets were significantly decreased, only between 0.44 (95% CI: 0.43-0.45) and 0.65 (95% CI: 0.64-0.66). CONCLUSION Our results demonstrate performance inconsistency across the data sets and models, indicating that the high performance of deep learning models on one data set cannot be readily transferred to unseen external data sets, and these models need further assessment and validation before being applied in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacr.2020.01.006

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 174

Metadata

Authors
Wang, X., Liang, G., Zhang, Y., Blanton, H., Bessinger, Z., & Jacobs, N.
Venue
Journal of the American College of Radiology
Publisher
Elsevier BV
Published
2020-06
Volume
17
Issue
6
Pages
796-803
ISSN
1546-1440 (ISSN-L)
OpenAlex
W3006379117
Cited by
174
References
10
FWCI
10.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inconsistent Performance of Deep Learning Models on Mammogram Classification. https://app.cochat.ai/papers/10.1016/j.jacr.2020.01.006
The paper
Wang, X., Liang, G., Zhang, Y., Blanton, H., Bessinger, Z., & Jacobs, N. (2020). Inconsistent Performance of Deep Learning Models on Mammogram Classification. Journal of the American College of Radiology. https://doi.org/10.1016/j.jacr.2020.01.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.