Characterization of expiration air jets and droplet size distributions immediately at the mouth opening
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Size distributions of expiratory droplets expelled during coughing and speaking and the velocities of the expiration air jets of healthy volunteers were measured. Droplet size was measured using the interferometric Mie imaging (IMI) technique while the particle image velocimetry (PIV) technique was used for measuring air velocity. These techniques allowed measurements in close proximity to the mouth and avoided air sampling losses. The average expiration air velocity was 11.7 m/s for coughing and 3.9 m/s for speaking. Under the experimental setting, evaporation and condensation effects had negligible impact on the measured droplet size. The geometric mean diameter of droplets from coughing was 13.5 μm and it was 16.0 μm for speaking (counting 1–100). The estimated total number of droplets expelled ranged from 947 to 2085 per cough and 112–6720 for speaking. The estimated droplet concentrations for coughing ranged from 2.4 to 5.2 cm−3 per cough and 0.004–0.223 cm−3 for speaking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867 · cited 3×
“Smaller pathogen-laden droplets have higher infectivity (Nicas, Nazaroff, & Hubbard, 2005) compared to the larger ones for diseases that have the lower respiratory tract as the target infection site (e.g., tuberculosis).”
BackgroundMethodInfluentialThe size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 6×
“…employing sampling-based instruments reported size peaks that are outside the IMI detection limit (e.g., 0.6 m for both coughing and talking by Papineni & Rosenthal, 1997), which suggests that the IMI system might not cover the entire size range of expiratory droplets and other size modes…”
BackgroundMethodInfluentialThe Size and Concentration of Droplets Generated by Coughing in Human Subjects
Yang, S., Lee, G. W. M., Chen, C.-M., Wu, C.-C., & Yu, K.-P. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0610 · Cited by 473
Zhu, S., Kato, S., & Yang, J.-H. (2006) · Building and Environment · doi:10.1016/j.buildenv.2005.06.024 · Cited by 428
Thermal mapping of the airways in humans
McFadden, E. R., Pichurko, B. M., Bowman, H. F., Ingenito, E., Burns, S., Dowling, N., & Solway, J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.2.564 · Cited by 423
Glover, A. R., Skippon, S. M., & Boyle, R. D. (1995) · Applied Optics · doi:10.1364/ao.34.008409 · Cited by 280
Droplet expulsion from the respiratory tract.
(1967) · PubMed · doi:10.1164/arrd.1967.95.3.435 · Cited by 240 · cited 12×
“The results reported by Duguid (1946) and Loudon and Roberts (1967) are also plotted on Fig.”
BackgroundMethodResultInfluentialLight scattering from water droplets in the geometrical optics approximation
Glantschnig, W. J., & Chen, S.-H. (1981) · Applied Optics · doi:10.1364/ao.20.002499 · Cited by 200
Particle Concentration in Exhaled Breath
FAIRCHILD, C. I., & STAMPFER, J. F. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385868 · Cited by 175
The interdependence of evaporation and settling for airborne freely falling droplets
Kukkonen, J., Vesala, T., & Kulmala, M. (1989) · Journal of Aerosol Science · doi:10.1016/0021-8502(89)90087-6 · Cited by 99
Impact of Health on Particle Size of Exhaled Respiratory Aerosols: Case‐control Study
Hersen, G., Moularat, S., Robine, E., Géhin, E., Corbet, S., Vabret, A., & Freymuth, F. (2008) · CLEAN – Soil, Air, Water · doi:10.1002/clen.200700189 · Cited by 56 · cited 1×
“On the other hand, a recent study by Hersen et al. (2008) indicated that the size distributions of exhaled respiratory aerosols from symptomatic individuals were different from that exhaled by healthy individuals.”
BackgroundSevere acute respiratory syndrome (SARS): breath-taking progress
Hawkey, P. M., Bhagani, S., & Gillespie, S. H. (2003) · Journal of Medical Microbiology · doi:10.1099/jmm.0.05321-0 · Cited by 31
Droplets expelled during human expiratory activities and their origin
Morawska, L., Johnson, G. R., Ristovski, Z., Hargreaves, M. H., Mengersen, K. L., Chao, C. Y. H., Wan, M. P., Li, Y., Xie, X., & Katoshevski, D. (2008) · QUT ePrints (Queensland University of Technology) · Cited by 17
Self-citation
Research works printed but not linked: 1
- Jennison, 1942, Atomizing of mouth and nose secretions into the air as revealed by high speed photography, Aerobiology, 17, 106
Cited by
Airborne transmission of SARS-CoV-2: The world should face the reality
Morawska, L., & Cao, J. (2020) · Environment International · doi:10.1016/j.envint.2020.105730 · Cited by 1,728
Self-citationAirborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
Stadnytskyi, V., Bax, C. E., Bax, A., & Anfinrud, P. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2006874117 · Cited by 1,077
Aerosol Emission and Superemission during Human Speech Increase with Voice Loudness
Asadi, S., Wexler, A. S., Cappa, C. D., Barreda, S., Bouvier, N. M., & Ristenpart, W. D. (2019) · Scientific Reports · doi:10.1038/s41598-019-38808-z · Cited by 919
Buonanno, G., Stabile, L., & Morawska, L. (2020) · Environment International · doi:10.1016/j.envint.2020.105794 · Cited by 780
Self-citation
Metadata
- Authors
- Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., & Katoshevski, D.
- Venue
- Journal of Aerosol Science
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 40
- Issue
- 2
- Pages
- 122-133
- ISSN
- 0021-8502 (ISSN-L)
- OpenAlex
- W2019398050
- Cited by
- 1,087
- References
- 14
- FWCI
- 14.75
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.