The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
QRS detection using K-Nearest Neighbor algorithm (KNN) and evaluation on standard ECG databases
Open accessAbstract
The performance of computer aided ECG analysis depends on the precise and accurate delineation of QRS-complexes. This paper presents an application of K-Nearest Neighbor (KNN) algorithm as a classifier for detection of QRS-complex in ECG. The proposed algorithm is evaluated on two manually annotated standard databases such as CSE and MIT-BIH Arrhythmia database. In this work, a digital band-pass filter is used to reduce false detection caused by interference present in ECG signal and further gradient of the signal is used as a feature for QRS-detection. In addition the accuracy of KNN based classifier is largely dependent on the value of K and type of distance metric. The value of K = 3 and Euclidean distance metric has been proposed for the KNN classifier, using fivefold cross-validation. The detection rates of 99.89% and 99.81% are achieved for CSE and MIT-BIH databases respectively. The QRS detector obtained a sensitivity Se = 99.86% and specificity Sp = 99.86% for CSE database, and Se = 99.81% and Sp = 99.86% for MIT-BIH Arrhythmia database. A comparison is also made between proposed algorithm and other published work using CSE and MIT-BIH Arrhythmia databases. These results clearly establishes KNN algorithm for reliable and accurate QRS-detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
The Massachusetts Institute of Technology
Endowed, S. C. F. (1999) · Anthropology News · doi:10.1111/an.1999.40.2.6 · Cited by 3,135
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597
The principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 1×
“Friesen et al. [18] have presented a comparison of nine QRS detection algorithms based on: (i) amplitude and first derivative, (ii) first derivative only, (iii) first and second derivative and (iv) digital filtering.”
MethodReal time electrocardiogram QRS detection using combined adaptive threshold
Christov, I. I. (2004) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-3-28 · Cited by 464
Neural-network-based adaptive matched filtering for QRS detection
Xue, Q., Hu, Y. H., & Tompkins, W. J. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126604 · Cited by 423
A novel method for detecting R-peaks in electrocardiogram (ECG) signal
Manikandan, M. S., & Soman, K. P. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.03.004 · Cited by 393
Using wavelet transforms for ECG characterization. An on-line digital signal processing system
Sahambi, J. S., Tandon, S. N., & Bhatt, R. K. P. (1997) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.566158 · Cited by 357
Ruha, A., Sallinen, S., & Nissila, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554762 · Cited by 255
An approach to QRS complex detection using mathematical morphology
Trahanias, P. E. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.212060 · Cited by 193
A reference data base for multilead electrocardiographic computer measurement programs
Willems, J. L., Arnaud, P., van Bemmel, J. H., Bourdillon, P. J., Degani, R., Denis, B., Graham, I. D., Harms, F. M. A., Macfarlane, P. W., Mazzocca, G., et al. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80136-5 · Cited by 156
QRS complex detection using Empirical Mode Decomposition
Slimane, Z. E. H., & Naït-Ali, A. (2009) · Digital Signal Processing · doi:10.1016/j.dsp.2009.10.017 · Cited by 136
Towards a generalized scheme for QRS detection in ECG waveforms
Gritzali, F. (1988) · Signal Processing · doi:10.1016/0165-1684(88)90069-2 · Cited by 124
ANN-based QRS-complex analysis of ECG
Vijaya, G., Kumar, V., & Verma, H. (1998) · Journal of Medical Engineering & Technology · doi:10.3109/03091909809032534 · Cited by 114
Classification of EEG signals using Dempster Shafer theory and a k-nearest neighbor classifier
Yazdani, A., Ebrahimi, T., & Hoffmann, U. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109299 · Cited by 96
Analysis of ECG from pole-zero models
Murthy, I. S. N., & Prasad, G. S. S. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142649 · Cited by 91
QRS complex detection based on multi wavelet packet decomposition
Chouakri, S. A., Bereksi-Reguig, F., & Ahmed, A. T. (2011) · Applied Mathematics and Computation · doi:10.1016/j.amc.2011.03.001 · Cited by 82
Detection of QRS Complexes in 12-lead ECG using Adaptive Quantized Threshold
Chouhan, V. S., Mehta, S. S., & Vyas, J. N. (2008) · Cited by 77
K-means algorithm for the detection and delineation of QRS-complexes in Electrocardiogram
Mehta, S. S., Shete, D., Lingayat, N. S., & Chouhan, V. S. (2009) · IRBM · doi:10.1016/j.irbm.2009.10.001 · Cited by 71
Mehta, S. S., & Lingayat, N. S. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2008.04.002 · Cited by 45
QRS detection using new wavelets
Saxena, S., Kumar, V., & Hamde, S. T. (2002) · Journal of Medical Engineering & Technology · doi:10.1080/03091900110096038 · Cited by 44
Development of entropy based algorithm for cardiac beat detection in 12-lead electrocardiogram
Mehta, S. S., & Lingayat, N. S. (2007) · Signal Processing · doi:10.1016/j.sigpro.2007.06.009 · Cited by 39
QRS detection through time recursive prediction techniques
Kyrkos, A., Giakoumakis, E. A., & Carayannis, G. V. (1988) · Signal Processing · doi:10.1016/0165-1684(88)90061-8 · Cited by 39
Cited by
Artificial Intelligence in Precision Cardiovascular Medicine
Krittanawong, C., Zhang, H., Wang, Z., Aydar, M., & Kitai, T. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.571 · Cited by 1,120
Venkatesan, C., Karthigaikumar, P., Paul, A., Satheeskumaran, S., & Kumar, R. (2018) · IEEE Access · doi:10.1109/access.2018.2794346 · Cited by 286
A novel k NN algorithm with data-driven k parameter computation
Zhang, S., Cheng, D., Deng, Z., Zong, M., & Deng, X. (2018) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.09.036 · Cited by 278
Niu, G., Yang, P., Zheng, Y., Cai, X., & Qin, H. (2021) · Water Resources Research · doi:10.1029/2020wr029121 · Cited by 19
“…based on its k nearest prelabeled instances in the high dimensional space defined by input features (Zhang et al., 2017). k NN is an easy to implement and highly efficient supervised learning algorithm that has been widely applied in studies (Bhatia, 2010; Peterson, 2009; Saini et al., 2013).”
Method
Metadata
- Authors
- Saini, I., Singh, D., & Khosla, A.
- Venue
- Journal of Advanced Research
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 4
- Issue
- 4
- Pages
- 331-344
- ISSN
- 2090-1224 (ISSN-L)
- 2090-1232
- OpenAlex
- W1973163442
- Cited by
- 346
- References
- 26
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.