Polymeric materials and films in dentistry: An overview
Open accessThe DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Abstract
The use of polymeric materials (PMs) and polymeric films (PMFs) has increased in medicine and dentistry. This increasing interest is attributed to not only the excellent surfaces of PMs and PMFs but also their desired mechanical and biological properties, low production cost, and ease in processing, allowing them to be tailored for a wide range of applications. Specifically, PMs and PMFs are used in dentistry for their antimicrobial, drug delivery properties; in preventive, restorative and regenerative therapies; and for corrosion and friction reduction. PMFs such as acrylic acid copolymers are used as a dental adhesive; polylactic acids are used for dental pulp and dentin regeneration, and bioactive polymers are used as advanced drug delivery systems. The objective of this article was to review the literatures on the latest advancements in the use of PMs and PMFs in medicine and dentistry. Published literature (1990-2017) on PMs and PMFs for use in medicine and dentistry was reviewed using MEDLINE/PubMed and ScienceDirect resources. Furthermore, this review also explores the diversity of latest PMs and PMFs that have been utilized in dental applications, and analyzes the benefits and limitations of PMs and PMFs. Most of the PMs and PMFs have shown to improve the biomechanical properties of dental materials, but in future, more clinical studies are needed to create better treatment guidelines for patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834 · cited 1×
“Graphene, discovered in 2004 [71], is an allotrope of carbon with a one-atom-thick planar sheet of sp(2) bonded carbon atoms that are densely packed in a honeycomb crystal lattice [9,72].”
BackgroundGraphene-based composite materials
Stankovich, S., Dikin, D. A., Dommett, G. H. B., Kohlhaas, K. M., Zimney, E. J., Stach, E. A., Piner, R. D., Nguyen, S. T., & Ruoff, R. S. (2006) · Nature · doi:10.1038/nature04969 · Cited by 12,922 · cited 1×
“Graphene oxide (GO) materials are widely studied for fabricating various nanocomposites of different polymer matrixes for different applications [9,74].”
BackgroundHydrogel: Preparation, characterization, and applications: A review
Ahmed, E. M. (2015) · Journal of Advanced Research · doi:10.1016/j.jare.2013.07.006 · Cited by 5,800 · cited 1×
“Hydrogels comprise a group of PMs, the hydrophilic structure of which renders them capable of holding large amounts of water in their 3D networks [123].”
BackgroundPEGylation as a strategy for improving nanoparticle-based drug and gene delivery
Suk, J. S., Xu, Q., Kim, N., Hanes, J., & Ensign, L. M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.012 · Cited by 4,523 · cited 1×
“The NPs incorporated with polyethylene glycol (PEG), or subjected to ‘PEGylation’ improved the efficiency of drug and gene delivery to target cells and tissues [38].”
BackgroundBiofilms: Microbial Life on Surfaces
Donlan, R. M. (2002) · Emerging Infectious Diseases · doi:10.3201/eid0809.020063 · Cited by 4,145 · cited 1×
“Microbial adhesion is followed by bacterial growth and colonization, resulting in the formation of a compact biofilm matrix [11].”
BackgroundRecent advances in graphene based polymer composites
Kuilla, T., Bhadra, S., Yao, D., Kim, N. H., Bose, S., & Lee, J. H. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.07.005 · Cited by 3,406 · cited 4×
“The increased use of engineering and nanotechnology in medicine and dentistry has led to the development of improved PMs for dental applications [9].”
BackgroundInfluentialSynthesis of Water Soluble Graphene
Si, Y., & Samulski, E. T. (2008) · Nano Letters · doi:10.1021/nl080604h · Cited by 2,722 · cited 1×
“The polymer graphene, which has been described as the ‘‘thinnest material in the universe”, has attracted attention in various fields, including dentistry, because it has dramatically improved mechanical properties [70].”
BackgroundSurface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406 · cited 2×
“Rough surfaced implants increase osseointegration and biomechanical stability [76].”
BackgroundPoly(lactic acid) modifications
Rasal, R. M., Janorkar, A. V., & Hirt, D. E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.12.003 · Cited by 2,204 · cited 5×
“Polylactic acid (PLLA), a popular low-cost biodegradable polymer has excellent biocompatibility and good mechanical properties (particularly tensile Young’s modulus, tensile strength, and flexural strength) compared with polyethylene and polysulfide [86,87].”
BackgroundInfluentialGraphene: carbon in two dimensions
Katsnelson, M. I. (2007) · Materials Today · doi:10.1016/s1369-7021(06)71788-6 · Cited by 2,008
Behl, M., & Lendlein, A. (2007) · Materials Today · doi:10.1016/s1369-7021(07)70047-0 · Cited by 1,965
Kamoun, E. A., Kenawy, E.-R. S., & Chen, X. (2017) · Journal of Advanced Research · doi:10.1016/j.jare.2017.01.005 · Cited by 1,707 · cited 1×
“In addition, single component hydrogels have low mechanical strength, and recent studies have used composite or hybrid hydrogel membranes to increase the hydrogel strength [125].”
BackgroundNavarro, M., Michiardi, A., Castaño, O., & Planell, J. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0151 · Cited by 1,513 · cited 1×
“Despite the wide availability of biomaterials, no material has ideal physical, mechanical, biological, and surface characteristics [4].”
BackgroundPoly-lactic acid synthesis for application in biomedical devices — A review
Lasprilla, A. J. R., Martinez, G. A. R., Lunelli, B. H., Jardini, A. L., & Filho, R. M. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.019 · Cited by 1,174 · cited 1×
“PLLA has wide applications in medical sciences and is used in a range of devices, including degradable sutures, drug releasing micro-particles, nano-particles, and porous scaffolds for cellular applications [88].”
BackgroundAmphotericin B: 30 Years of Clinical Experience
Gallis, H. A., Drew, R. H., & Pickard, W. W. (1990) · Clinical Infectious Diseases · doi:10.1093/clinids/12.2.308 · Cited by 1,009
Implant biomaterials: A comprehensive review
Saini, M. (2015) · World Journal of Clinical Cases · doi:10.12998/wjcc.v3.i1.52 · Cited by 844
Applications of synthetic polymers in clinical medicine
Maitz, M. F. (2015) · Biosurface and Biotribology · doi:10.1016/j.bsbt.2015.08.002 · Cited by 726 · cited 2×
“Polymeric materials (PMs) are widely used in biomedical fields [6], and their use has increased due to their improved properties and wide applicability.”
BackgroundFew layer graphene to reduce wear and friction on sliding steel surfaces
Berman, D., Erdemir, A., & Sumant, A. V. (2013) · Carbon · doi:10.1016/j.carbon.2012.11.061 · Cited by 721
Chitosan based hydrogels: characteristics and pharmaceutical applications.
Ahmadi, F., Ovaisi, Z., Samani, S. M., & Amoozgar, Z. (2015) · PubMed Central · Cited by 666
Graphene based materials for biomedical applications
Yang, Y., Asiri, A. M., Tang, Z., Du, D., & Lin, Y. (2013) · Materials Today · doi:10.1016/j.mattod.2013.09.004 · Cited by 653 · cited 1×
“The corrosion inhibiting effect of graphene suggests that it could be coated on arch wires used in orthodontics, metal files and reamers used in endodontics, or metal prostheses [113,114,117].”
BackgroundMechanical properties of a novel PVA hydrogel in shear and unconfined compression
Stammen, J. A., Williams, S., Ku, D. N., & Guldberg, R. E. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00242-8 · Cited by 624
Degradation, Fatigue, and Failure of Resin Dental Composite Materials
Drummond, J. L. (2008) · Journal of Dental Research · doi:10.1177/154405910808700802 · Cited by 602 · cited 1×
“Thus, the disadvantages of composite restorations include polymerization shrinkage, secondary caries, and restorative material fracture [46,47].”
BackgroundExploring graphene as a corrosion protection barrier
Kirkland, N. T., Schiller, T., Medhekar, N., & Birbilis, N. (2012) · Corrosion Science · doi:10.1016/j.corsci.2011.12.003 · Cited by 601 · cited 1×
“The corrosion inhibiting effect of graphene suggests that it could be coated on arch wires used in orthodontics, metal files and reamers used in endodontics, or metal prostheses [113,114,117].”
BackgroundPoly(lactic acid) blends in biomedical applications
Saini, P., Arora, M., & Kumar, M. N. V. R. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.014 · Cited by 549 · cited 1×
“Polylactic acid (PLLA), a popular low-cost biodegradable polymer has excellent biocompatibility and good mechanical properties (particularly tensile Young’s modulus, tensile strength, and flexural strength) compared with polyethylene and polysulfide [86,87].”
BackgroundBioadhesive microspheres as a controlled drug delivery system
Vasir, J. K., Tambwekar, K., & Garg, S. (2003) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(03)00087-5 · Cited by 524 · cited 1×
“The polymer microsphere-based systems used for delivery included molecules ranging from smaller molecules to peptides; and macromolecular drugs such as proteins, oligonucleotides and DNA [41].”
BackgroundThe Use of Nanoparticles to Control Oral Biofilm Formation
Allaker, R. P. (2010) · Journal of Dental Research · doi:10.1177/0022034510377794 · Cited by 509 · cited 1×
“Nanotechnology and polymeric nanomaterials have been used to prevent bacterial adhesion and biofilm formation [20,21].”
BackgroundModification of Graphene Platelets and their Tribological Properties as a Lubricant Additive
Lin, J., Wang, L., & Chen, G. (2011) · Tribology Letters · doi:10.1007/s11249-010-9702-5 · Cited by 480 · cited 1×
“[122] who used a graphene platelet coating to reduce friction.”
MethodPolylactic acid (PLA): Research, development and industrialization
Pang, X., Zhuang, X., Tang, Z., & Chen, X. (2010) · Biotechnology Journal · doi:10.1002/biot.201000135 · Cited by 435 · cited 1×
“Polylactic acid (PLLA), a popular low-cost biodegradable polymer has excellent biocompatibility and good mechanical properties (particularly tensile Young’s modulus, tensile strength, and flexural strength) compared with polyethylene and polysulfide [86,87].”
BackgroundNanomaterials in preventive dentistry
Hannig, M., & Hannig, C. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.83 · Cited by 414 · cited 1×
“Nanotechnology and polymeric nanomaterials have been used to prevent bacterial adhesion and biofilm formation [20,21].”
BackgroundPMMA: An Essential Material in Medicine and Dentistry
Frazer, R. Q., Byron, R. T., Osborne, P. B., & West, K. P. (2005) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v15.i6.60 · Cited by 376 · cited 1×
“However, PMMA has certain disadvantages; it swells and dissolves in many organic solvents and chemicals due to its easily hydrolyzable esters groups [62].”
BackgroundLi, M., Liu, Q., Jia, Z., Xu, X., Cheng, Y., Zheng, Y., Xi, T., & Wei, S. (2014) · Carbon · doi:10.1016/j.carbon.2013.09.080 · Cited by 309
Tavassoli Hojati, S., Alaghemand, H., Hamze, F., Ahmadian Babaki, F., Rajab-Nia, R., Rezvani, M. B., Kaviani, M., & Atai, M. (2013) · Dental Materials · doi:10.1016/j.dental.2013.03.011 · Cited by 305 · cited 1×
“Adding different antibacterial agents such as, quaternary ammonium compounds [12], inorganic nanoparticles (NPs) [13,14], or fluoride varnish with natural products [15] into the dental materials prevents biofilm formation and bacterial growth.”
BackgroundAn in vitro quantitative antibacterial analysis of amalgam and composite resins
Beyth, N., Domb, A. J., & Weiss, E. I. (2007) · Journal of Dentistry · doi:10.1016/j.jdent.2006.07.009 · Cited by 267 · cited 1×
“In addition, many restorative materials, including resins and composites accumulate more biofilm than other restorative materials, such as amalgam and dental restorative cements [48,49].”
BackgroundPolymer/nanosilver composite coatings for antibacterial applications
Guo, L., Yuan, W., Lu, Z., & Li, C. M. (2013) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2012.12.029 · Cited by 267 · cited 1×
“Polymers have been used to fabricate nanosilver nanocomposites with better properties and enhanced antibacterial activity [68].”
MethodThe dentin organic matrix – limitations of restorative dentistry hidden on the nanometer scale
Bertassoni, L. E., Orgel, J. P. R., Antipova, O., & Swain, M. V. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.02.022 · Cited by 223 · cited 1×
“Because of the high complexity of the tooth organic substrate, collagen and dentin proteins, it is difficult to achieve the optimal interaction between polymers and dentin [45].”
BackgroundNanoparticles vs. biofilms: a battle against another paradigm of antibiotic resistance
Qayyum, S., & Khan, A. U. (2016) · MedChemComm · doi:10.1039/c6md00124f · Cited by 213 · cited 2×
“These microbes produce excessive extracellular polymeric substances (EPS) that protect them from their environment and antibiotics, thereby making them antibiotic resistant [19].”
BackgroundVisible light crosslinkable chitosan hydrogels for tissue engineering
Hu, J., Hou, Y., Park, H., Choi, B., Hou, S., Chung, A., & Lee, M. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.01.029 · Cited by 212
Biocomposites and hybrid biomaterials based on calcium orthophosphates
Dorozhkin, S. V. (2011) · Biomatter · doi:10.4161/biom.1.1.16782 · Cited by 198 · cited 1×
“Polymethyl methacrylate (PMMA) is widely used as biomedical material to make various types of prostheses in medicine and dentistry [60].”
BackgroundPlasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface
Walsh, W. R., Bertollo, N., Christou, C., Schaffner, D., & Mobbs, R. J. (2015) · The Spine Journal · doi:10.1016/j.spinee.2014.12.018 · Cited by 197 · cited 1×
“Polymeric films that can be used as coatings over NiTi, stainless steel wire and other materials to prevent corrosion are Pyy/HA nanocomposite [103], PUR [105], polyamide [106], polyetheretherketone [107], polytetrafluoroethylene [108], graphene oxide/HA [109], hexamethyldisilazane [110], and fullerene like-tungsten d…”
BackgroundHu, Y., Daoud, W., Cheuk, K., & Lin, C. (2016) · Materials · doi:10.3390/ma9030133 · Cited by 194 · cited 5×
“Polylactic acid (PLLA), a popular low-cost biodegradable polymer has excellent biocompatibility and good mechanical properties (particularly tensile Young’s modulus, tensile strength, and flexural strength) compared with polyethylene and polysulfide [86,87].”
BackgroundInfluentialAdverse effects of antifungal therapies in invasive fungal infections: review and meta-analysis
Girois, S. B., Chapuis, F., Decullier, E., & Revol, B. G. P. (2006) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-005-0080-0 · Cited by 173
Wassel, M. O., & Khattab, M. A. (2017) · Journal of Advanced Research · doi:10.1016/j.jare.2017.05.006 · Cited by 162 · cited 2×
“Adding different antibacterial agents such as, quaternary ammonium compounds [12], inorganic nanoparticles (NPs) [13,14], or fluoride varnish with natural products [15] into the dental materials prevents biofilm formation and bacterial growth.”
BackgroundMetal wear and tissue response in failed titanium alloy total hip replacements
Witt, J., & Swann, M. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b4.2071635 · Cited by 161 · cited 1×
“This has led to concerns about the long-term metabolic, oncogenic, and immunological effects of Ti particles [97,98].”
BackgroundOral local drug delivery and new perspectives in oral drug formulation
Paderni, C., Compilato, D., Giannola, L. I., & Campisi, G. (2012) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2012.02.016 · Cited by 158 · cited 2×
“The bioadhesive formulations protect fragile drugs and improve the retention time of active substances ranging from days to months improving the efficacy of the treatments resulting in patient comfort and compliance [35].”
BackgroundElectrical Implications of Corrosion for Osseointegration of Titanium Implants
Gittens, R. A., Olivares‐Navarrete, R., Tannenbaum, R., Boyan, B. D., & Schwartz, Z. (2011) · Journal of Dental Research · doi:10.1177/0022034511408428 · Cited by 151 · cited 1×
“The reduced oxygen concentration from the poor vasculature at the implant surface interface promotes a buildup of host-cell-related electrons as free radicals and proton acid that can encourage infection and inflammation causing implant failure [78,79].”
BackgroundN-succinyl chitosan–dialdehyde starch hybrid hydrogels for biomedical applications
Kamoun, E. A. (2015) · Journal of Advanced Research · doi:10.1016/j.jare.2015.02.002 · Cited by 149
Li, Z., Sun, J., Lan, J. Q., & Qi, Q. (2014) · Gerodontology · doi:10.1111/ger.12142 · Cited by 141
Silver–polysaccharide nanocomposite antimicrobial coatings for methacrylic thermosets
Travan, A., Marsich, E., Donati, I., Benincasa, M., Giazzon, M., Felisari, L., & Paoletti, S. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.07.024 · Cited by 134 · cited 1×
“[69] developed an antimicrobial nanocomposite using lactose-modified chitosan incorporated with Ag-NPs for the heat polymerized PMMA that is used in dentistry.”
MethodFrisken, K. W., Dandie, G., Lugowski, S., & Jordan, G. (2002) · Australian Dental Journal · doi:10.1111/j.1834-7819.2002.tb00331.x · Cited by 134 · cited 1×
“It was found that after placing single threaded screw implants into sheep mandibles, the Ti levels were below 400 ppb [99].”
BackgroundGad, M. M., Al‐Thobity, A. M., Shahin, S., Alsaqer, B. T., & Ali, A. A. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s142857 · Cited by 133 · cited 2×
“albicans adhesion to denture bases and cold-cured removable prosthesis [63].”
BackgroundTepe, G., Schmehl, J., Wendel, H. P., Schaffner, S., Heller, S., Gianotti, M., Claussen, C. D., & Duda, S. H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.06.004 · Cited by 132 · cited 2×
“Polymeric films that can be used as coatings over NiTi, stainless steel wire and other materials to prevent corrosion are Pyy/HA nanocomposite [103], PUR [105], polyamide [106], polyetheretherketone [107], polytetrafluoroethylene [108], graphene oxide/HA [109], hexamethyldisilazane [110], and fullerene like-tungsten d…”
BackgroundDegrazia, F. W., Leitune, V. C. B., García, I. M., Arthur, R. A., Samuel, S. M. W., & Collares, F. M. (2016) · Journal of Applied Oral Science · doi:10.1590/1678-775720160154 · Cited by 126 · cited 1×
“Adding different antibacterial agents such as, quaternary ammonium compounds [12], inorganic nanoparticles (NPs) [13,14], or fluoride varnish with natural products [15] into the dental materials prevents biofilm formation and bacterial growth.”
BackgroundBiofilm and Dental Biomaterials
Øilo, M., & Bakken, V. (2015) · Materials · doi:10.3390/ma8062887 · Cited by 123
Iatrogenic possibilities of orthodontic treatment and modalities of prevention
Meeran, N. (2013) · Journal of Orthodontic Science · doi:10.4103/2278-0203.119678 · Cited by 119 · cited 1×
“The oral signs and symptoms resulting from Ni released from orthodontic appliances include gingival hyperplasia, stomatitis, angular cheilitis, perioral rash, erythema multiforme, burning sensation, and loss of taste [95,96].”
BackgroundRavichandran, R., Ng, C. C., Liao, S., Pliszka, D., Raghunath, M., Ramakrishna, S., & Chan, C. K. (2011) · Biomedical Materials · doi:10.1088/1748-6041/7/1/015001 · Cited by 116 · cited 1×
“Biomimetic coated Ti surfaces with nano-hydroxyapatite (nHA) and poly(lactic-co-glycolic acid) (PLGA)/collagen nanofibers have been studied for dental and bone implant surfaces to enhance osseointegration [81].”
BackgroundHirota, K., Murakami, K., Nemoto, K., & Miyake, Y. (2005) · FEMS Microbiology Letters · doi:10.1016/j.femsle.2005.05.019 · Cited by 112
Graphene coated Ni films: A protective coating
Nayak, P. K., Hsu, C.-J., Wang, S., et al. (2012) · Thin Solid Films · doi:10.1016/j.tsf.2012.03.067 · Cited by 110 · cited 2×
“The corrosion inhibiting effect of graphene suggests that it could be coated on arch wires used in orthodontics, metal files and reamers used in endodontics, or metal prostheses [113,114,117].”
BackgroundLee, S. B., González‐Cabezas, C., Kim, K., Kim, K., & Kuroda, K. (2015) · Biomacromolecules · doi:10.1021/acs.biomac.5b00451 · Cited by 107
Dedinaite, A., Lundin, M., Macakova, L., & Auletta, T. (2005) · Langmuir · doi:10.1021/la0511844 · Cited by 106
Posterior composite restoration update: focus on factors influencing form and function
Bohaty, B. S., Spencer, P., Misra, A. K., Ye, & Sene (2013) · Clinical Cosmetic and Investigational Dentistry · doi:10.2147/ccide.s42044 · Cited by 104 · cited 1×
“Thus, the disadvantages of composite restorations include polymerization shrinkage, secondary caries, and restorative material fracture [46,47].”
BackgroundIn vitro study of nano-hydroxyapatite/chitosan–gelatin composites for bio-applications
Mohamed, K. R., Beherei, H. H., & El-Rashidy, Z. M. (2013) · Journal of Advanced Research · doi:10.1016/j.jare.2013.02.004 · Cited by 101
The Effect of Titanium Surface Modifications on Dental Implant Osseointegration
Annunziata, M., & Guida, L. (2015) · Frontiers of oral physiology/Frontiers of oral biology · doi:10.1159/000381694 · Cited by 94 · cited 1×
“Implant surface treatment methods include Ti plasma-spraying, grit-blasting, acidetching, anodization and calcium phosphate coatings [77].”
BackgroundFong, E. L. S., Watson, B. M., Kasper, F. K., & Mikos, A. G. (2012) · Advanced Materials · doi:10.1002/adma.201201762 · Cited by 89 · cited 1×
“This material is useful in dentistry for reducing the friction and wear of dental biomaterials [133].”
BackgroundCross-linking of poly(N-vinyl pyrrolidone) films by electron beam irradiation
Burkert, S., Schmidt, T., Gohs, U., Dorschner, H., & Arndt, K. (2007) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2007.02.024 · Cited by 88 · cited 1×
“Their properties include biodegradation, and chemical and biological response to stimuli [124].”
BackgroundBiodegradable functional polycarbonate micelles for controlled release of amphotericin B
Wang, Y., Ke, X., Voo, Z. X., Yap, S. S. L., Yang, C. H., Gao, S., Liu, S., Venkataraman, S., Obuobi, S. A. O., Khara, J. S., et al. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.09.036 · Cited by 87 · cited 2×
“[39] assembled phenylboronic acid-functionalized polycarbonate (PBC)/PEG and urea functionalized polycarbonate (PUC)/PEG diblock copolymers incorporated with AmB.”
BackgroundMethodKang, S., Lee, M., Kang, M., Noh, M., Jeon, J., Lee, Y., & Seo, J. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.03.006 · Cited by 87
Makihira, S., Mine, Y., Nikawa, H., Shuto, T., Iwata, S., Hosokawa, R., Kamoi, K., Okazaki, S., & Yamaguchi, Y. (2010) · Toxicology in Vitro · doi:10.1016/j.tiv.2010.07.023 · Cited by 86 · cited 2×
“Although, Ti at levels of 5–9 ppm may be involved in cytotoxicity, inflammation, and necrosis at >13 ppm at the interfaces of dental implants and gingival tissue [101], currently there are no clinical reports about Ti toxicity.”
BackgroundBottino, M. C., Arthur, R. A., Waeiss, R. A., Kamocki, K., Gregson, K. S., & Gregory, R. L. (2014) · Clinical Oral Investigations · doi:10.1007/s00784-014-1201-x · Cited by 86
Accumulation of Streptococcus mutans on Light‐Cured Composites and Amalgam: An In Vitro Study
ZALKIND, M. M., KEISAR, O., EVER‐HADANI, P., GRINBERG, R., & SELA, M. N. (1998) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/j.1708-8240.1998.tb00356.x · Cited by 83 · cited 1×
“In addition, many restorative materials, including resins and composites accumulate more biofilm than other restorative materials, such as amalgam and dental restorative cements [48,49].”
BackgroundPectin, alginate and gum arabic polymers reduce citric acid erosion effects on human enamel
Beyer, M., Reichert, J., Heurich, E., Jandt, K. D., & Sigusch, B. W. (2010) · Dental Materials · doi:10.1016/j.dental.2010.04.008 · Cited by 80 · cited 1×
“The polymers (propylene glycol alginate, highly esterified pectin and gum arabic) adsorbed on the teeth forming a protective layer on the enamel and dentin that reduced the erosive effects of acid [26].”
BackgroundCatt, K. A., Li, H., & Cui, X. T. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.11.039 · Cited by 79 · cited 1×
“biocompatible polymer 3,4-ethylenedioxythiphene and GO composite coating effectively reduced the corrosion of Mg-based medical implants [115].”
BackgroundShahi, R., de Albuquerque, M. T. P., Münchow, E. A., Blanchard, S., Gregory, R. L., & Bottino, M. C. (2016) · Odontology · doi:10.1007/s10266-016-0268-z · Cited by 78 · cited 1×
“[89] used a tetracycline hydrochloride PLLA, poly(e-caprolactone), and gelatin polymer solution to synthesize tetracycline-containing fibers.”
MethodWest, A. E., Jones, M. L., & Newcombe, R. G. (1995) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(95)70046-3 · Cited by 77 · cited 1×
“Orthodontic arch wires that can deliver light forces over time would be useful to clinicians during the initial alignment phase of fixed appliance treatment [118].”
BackgroundA novel protein-repellent dental composite containing 2-methacryloyloxyethyl phosphorylcholine
Zhang, N., Chen, C., Melo, M. A. S., Bai, Y., Cheng, L., & Xu, H. H. K. (2015) · International Journal of Oral Science · doi:10.1038/ijos.2014.77 · Cited by 73 · cited 1×
“However, a disadvantage of MPC is its complicated synthesis resulting in high production cost, which limits their wide applicability [94].”
BackgroundZeta Potentials of Human Enamel and Hydroxyapatite as Measured by the Coulter® DELSA 440
Young, A., Smistad, G., Karlsen, J., Rölla, G., & Rykke, M. (1997) · Advances in Dental Research · doi:10.1177/08959374970110042501 · Cited by 71 · cited 1×
“Chitosan, due to the presence of a cationic amino group, has a high positive zeta-potential and readily adsorbs onto materials such as enamel of strong negative zeta potential [28] through electrostatic forces [29].”
BackgroundThe effect of the degree of deacetylation of chitosan on its dispersion of carbon nanotubes
Iamsamai, C., Hannongbua, S. V., Ruktanonchai, U., Soottitantawat, A., & Dubas, S. T. (2009) · Carbon · doi:10.1016/j.carbon.2009.06.060 · Cited by 69
Controlling biofilm formation with an N ‐halamine‐based polymeric additive
Luo, J., Chen, Z., & Sun, Y. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30689 · Cited by 69 · cited 1×
“Various anti-bacterial polymeric coatings such as acrylic acid, alkylmethacrylate, and polydimethylsiloxane copolymer [1], Carbopol [2], N-halaminebased polymer additive [58], and Ti oxidechitosan/ heparin multilayers [59] have been used to prevent biofilm formation and to increase restoration longevity (25).”
MethodBiofilm-induced changes to the composite surface
Nedeljković, I., Munck, J. D., Ungureanu, A.-A., Slomka, V., Bartic, C., Vananroye, A., Clasen, C., Teughels, W., MEERBEEK, B. V., & LANDUYT, K. L. V. (2017) · Journal of Dentistry · doi:10.1016/j.jdent.2017.05.015 · Cited by 66 · cited 1×
“Increased roughness and subsequent increased bacterial accumulation may facilitate the development of secondary caries around composites, which is the most common reason for composite restoration failure [53].”
BackgroundFornell, A.-C., Sköld‐Larsson, K., Hallgren, A., Bergstrand, F., & Twetman, S. H. A. (2002) · Acta Odontologica Scandinavica · doi:10.1080/000163502753471989 · Cited by 61 · cited 4×
“Various anti-bacterial polymeric coatings such as acrylic acid, alkylmethacrylate, and polydimethylsiloxane copolymer [1], Carbopol [2], N-halaminebased polymer additive [58], and Ti oxidechitosan/ heparin multilayers [59] have been used to prevent biofilm formation and to increase restoration longevity (25).”
BackgroundMethodInfluentialEffects of Ciprofloxacin-containing Scaffolds on Enterococcus faecalis Biofilms
de Albuquerque, M. T. P., Valera, M. C., Moreira, C. S., Bresciani, E., de Melo, R. M., & Bottino, M. C. (2015) · Journal of Endodontics · doi:10.1016/j.joen.2014.12.025 · Cited by 61
Nam, K.-Y. (2014) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2014.6.3.207 · Cited by 60
Yengopal, V., & Mickenautsch, S. (2011) · European Archives of Paediatric Dentistry · doi:10.1007/bf03262772 · Cited by 59
Nawasrah, A., Alnimr, A. M., & Ali, A. A. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13050520 · Cited by 58 · cited 1×
“Various additives such as zirconium oxide nanoparticles (ZrO2-NPs) [63], Yamani henna power [64], silver nanoparticles (Ag-NPs) [65] or platinum nanoparticles (Pt-NPs) [66] have been incorporated into PMMA to reduce bacterial or fungal colonization.”
BackgroundNam, J. A., Al‐Nahain, A., Kim, S. M., In, I., & Park, S. Y. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.04.022 · Cited by 54 · cited 1×
“[75] evaluated an antimicrobial nanocomposite composed of reduced graphene oxide using antimicrobial agents and catechol derivative conjugated to PEGgrafted poly (dimethylaminoethyl methacrylate).”
MethodSynthesis and characterization of a zwitterionic hydrogel blend with low coefficient of friction
Osaheni, A. O., Finkelstein, E. B., Mather, P. T., & Blum, M. M. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.09.022 · Cited by 52 · cited 1×
“[126] blended poly-vinyl alcohol with various amounts of zwitterionic polymer film, poly([2-(methacryloyloxy)ethyl] dimethyl-(3-sulfopropyl) ammonium hydroxide), demonstrating that biocompatible zwitterionic polymers reduced friction up to 80%.”
MethodNguyen, S., Hiorth, M., Rykke, M., & Smistad, G. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.03.004 · Cited by 51 · cited 3×
“For dental drug delivery, different pectin (LM-, HM- and AMpectin)-coated liposomes were effective because they adsorb on HA and the dental enamel [17].”
BackgroundPetersen, R. C. (2014) · Metals · doi:10.3390/met4040549 · Cited by 49 · cited 2×
“The reduced oxygen concentration from the poor vasculature at the implant surface interface promotes a buildup of host-cell-related electrons as free radicals and proton acid that can encourage infection and inflammation causing implant failure [78,79].”
BackgroundPolysaccharide-coated liposomal formulations for dental targeting
Pistone, S., Rykke, M., Smistad, G., & Hiorth, M. (2016) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2016.11.028 · Cited by 47 · cited 1×
“The negatively charged liposomes were the most stable in artificial saliva, and the stability of the positively charged liposomes in the film was improved using a negatively charged polysaccharide [23].”
BackgroundSheu, M., Chen, Y., Su, C.-Y., Jhan, H.-J., & Ho, H.-O. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s95194 · Cited by 40
Bader, R. A. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.02.015 · Cited by 35
Bisphenyl-Polymer/Carbon-Fiber-Reinforced Composite Compared to Titanium Alloy Bone Implant
Petersen, R. C. (2011) · International Journal of Polymer Science · doi:10.1155/2011/168924 · Cited by 22 · cited 1×
“Thermoset polymer matrix and carbon fibers generate covalent bonds providing strong bone structure support with excellent osseointegration [80].”
BackgroundTriazine Compound as Copolymerized Antibacterial Agent in Adhesive Resins
Schiroky, P. R., Leitune, V. C. B., García, I. M., Ogliari, F. A., Samuel, S. M. W., & Collares, F. M. (2017) · Brazilian Dental Journal · doi:10.1590/0103-6440201701346 · Cited by 19 · cited 1×
“Adding different antibacterial agents such as, quaternary ammonium compounds [12], inorganic nanoparticles (NPs) [13,14], or fluoride varnish with natural products [15] into the dental materials prevents biofilm formation and bacterial growth.”
BackgroundKhan, S. S., Feroz, S., & Bhoyar, A. G. (2016) · The Journal of Contemporary Dental Practice · doi:10.5005/jp-journals-10024-1966 · Cited by 8 · cited 1×
“[57] found that ZOE and zinc polycarboxylate (ZPC) cement showed antibacterial activity against S.”
Background
Cited by
Prosthodontic Applications of Polymethyl Methacrylate (PMMA): An Update
Zafar, M. S. (2020) · Polymers · doi:10.3390/polym12102299 · Cited by 717
Bioactive Glass Applications in Dentistry
Skallevold, H. E., Rokaya, D., Khurshid, Z., & Zafar, M. S. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20235960 · Cited by 335
Self-citationPolyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prostheses
Alqurashi, H., Khurshid, Z., Syed, A. U. Y., Rashid Habib, S., Rokaya, D., & Zafar, M. S. (2021) · Journal of Advanced Research · doi:10.1016/j.jare.2020.09.004 · Cited by 300
“Various removable appliances, restorations, and denture base materials are fabricated from polymers [1,2].”
BackgroundSelf-citationChe, J., Shi, J., Fang, C., Zeng, X., Wu, Z., Du, Q., Tu, M., & Pan, D. (2024) · Microorganisms · doi:10.3390/microorganisms12040704 · Cited by 52
Metadata
- Authors
- Rokaya, D., Srimaneepong, V., Sapkota, J., Qin, J., Siraleartmukul, K., & Siriwongrungson, V.
- Venue
- Journal of Advanced Research
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 14
- Pages
- 25-34
- ISSN
- 2090-1224 (ISSN-L)
- 2090-1232
- OpenAlex
- W2801357641
- Cited by
- 227
- References
- 93
- FWCI
- 18.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.