Reproducibility of blood pressure dipping: Relation to day-to-day variability in sleep quality
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background Previous studies of the reproducibility of blood pressure (BP) dipping have yielded inconsistent results. Few have examined factors that may influence dayto-day differences in dipping. Methods and Results Ambulatory BP monitoring was performed on three occasions, approximately one week apart, in 115 untreated adult subjects with elevated clinic BPs. The mean±SD BP dip was 18±7/15±5 mmHg (sleep/awake BP ratio = 0.87±0.05/0.82±0.06), with a median (interquartile range) day-to-day variation of 5.2 (3.1–8.1)/4.3(2.8–5.6) mmHg. There was no decrease in variability with successive measurements. The reproducibility coefficient (5.6 [95% CI 5.1, 6.1] mmHg) was greater and the intraclass correlation coefficient (0.53 [95% CI 0.42, 0.63]) was smaller for the systolic dip than for 24-hour or awake systolic BPs, suggesting greater day-today variability in dipping. Variability in systolic dipping was greater in subjects with higher awake BP, but was not related to age, gender, race, or body mass index. Within individuals, day-to-day variations in dipping were related to variations in the fragmentation index (p < 0.001), a measure of sleep quality. Conclusions Although mean 24-hour and awake BPs were relatively stable over repeated monitoring days, our study confirms substantial variability in BP dipping. Day-to-day differences in dipping are related to sleep quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Using the Berlin Questionnaire To Identify Patients at Risk for the Sleep Apnea Syndrome
Netzer, N. C., Stoohs, R. A., Netzer, C. M., Clark, K., & Strohl, K. P. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-7-199910050-00002 · Cited by 2,973
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Dolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227
Morgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Fagard, R. H., Celis, H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.100727 · Cited by 742
Mancia, G., Facchetti, R., Bombelli, M., Grassi, G., & Sega, R. (2006) · Hypertension · doi:10.1161/01.hyp.0000215363.69793.bb · Cited by 691
Relation Between Nocturnal Decline in Blood Pressure and Mortality The Ohasama Study
Ohkubo, T. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00274-4 · Cited by 491
Ben-Dov, I. Z., Kark, J. D., Ben-Ishay, D., Mekler, J., Ben-Arie, L., & Bursztyn, M. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.087262 · Cited by 367
Ambulatory Blood Pressure and Mortality: A Population-Based Study
Hansen, T. W., Jeppesen, J., Rasmussen, S., Ibsen, H., & Torp-Pedersen, C. (2005) · Hypertension · doi:10.1161/01.hyp.0000160402.39597.3b · Cited by 317
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Salles, G. F., Reboldi, G., Fagard, R. H., Cardoso, C. R. L., Pierdomenico, S. D., Verdecchia, P., Eguchi, K., Kario, K., Hoshide, S., Polonia, J., et al. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.06981 · Cited by 517
Nocturnal blood pressure measured by home devices: evidence and perspective for clinical application
Asayama, K., Fujiwara, T., Hoshide, S., Ohkubo, T., Kario, K., Stergiou, G. S., Parati, G., White, W. B., Weber, M. A., & Imai, Y. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000001987 · Cited by 120
Sleep efficiency and nocturnal hemodynamic dipping in young, normotensive adults
Ross, A. J., Yang, H., Larson, R. A., & Carter, J. R. (2014) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00211.2014 · Cited by 39
Reproducibility study of nocturnal blood pressure dipping in patients with high cardiovascular risk
Burgos‐Alonso, N., Ruiz Arzalluz, M. V., Garcia‐Alvarez, A., Fernandez‐Fernandez de Quincoces, D., & Grandes, G. (2021) · The Journal of Clinical Hypertension · doi:10.1111/jch.14222 · Cited by 19
Metadata
- Authors
- Hinderliter, A. L., Routledge, F. S., Blumenthal, J. A., Koch, G., Hussey, M. A., Wohlgemuth, W. K., & Sherwood, A.
- Venue
- Journal of the American Society of Hypertension
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 7
- Issue
- 6
- Pages
- 432-439
- ISSN
- 1878-7436 (ISSN-L)
- 1933-1711
- OpenAlex
- W2169291658
- Cited by
- 59
- References
- 12
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.