Rates, amounts, and determinants of ambulatory blood pressure monitoring claim reimbursements among Medicare beneficiaries
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Ambulatory blood pressure monitoring (ABPM) can be used to identify white coat hypertension and guide hypertensive treatment. We determined the percentage of ABPM claims submitted between 2007–2010 that were reimbursed. Among 1,970 Medicare beneficiaries with submitted claims, ABPM was reimbursed for 93.8% of claims that had an ICD-9 diagnosis code of 796.2 (“elevated blood pressure reading without diagnosis of hypertension”) versus 28.5% of claims without this code. Among claims without an ICD-9 diagnosis code of 796.2 listed, those for the component (e.g., recording, scanning analysis, physician review, reporting) versus full ABPM procedures and performed by institutional versus non-institutional providers were each more than two times as likely to be successfully reimbursed. Of the claims reimbursed, the median payment was $52.01 (25–75th percentiles: $32.95–$64.98). In conclusion, educating providers on the ABPM claims reimbursement process and evaluation of Medicare reimbursement may increase the appropriate use of ABPM and improve patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Use of Electronic Health Records in U.S. Hospitals
Jha, A. K., DesRoches, C. M., Campbell, E. G., Donelan, K., Rao, S. R., Ferris, T. G., Shields, A., Rosenbaum, S., & Blumenthal, D. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0900592 · Cited by 1,473 · cited 1×
“This finding is consistent with results of prior studies that have shown that larger, urban healthcare providers that are part of hospital systems are more likely to have extensive documentation processes, including health information technology systems and documentation improvement programs [15–17], that may lead to…”
ResultEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Stergiou, G. S., Asayama, K., Thijs, L., Kollias, A., Niiranen, T. J., Hozawa, A., Boggia, J., Johansson, J. K., Ohkubo, T., Tsuji, I., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02741 · Cited by 304
When and how to use self (home) and ambulatory blood pressure monitoring.
Pickering, T. G., & White, W. B. (2008) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2008.04.002 · Cited by 153
Resistant Hypertension: A Review of Diagnosis and Management
Vongpatanasin, W. (2014) · JAMA · doi:10.1001/jama.2014.5180 · Cited by 146
Cited by
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Self-citationWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.006 · Cited by 6,616
Self-citationMeasurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“ABPM is not widely available in primary care settings; white-coat hypertension is often the only indication for which ABPM will be reimbursed; and the amount of reimbursement is currently low.(196) In addition, ABPM may not be well tolerated by some patients, particularly at night.”
BackgroundSelf-citationWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000596 · Cited by 1,127
Self-citationRole of Ambulatory and Home Blood Pressure Monitoring in Clinical Practice: A Narrative Review
Shimbo, D., Abdalla, M., Falzon, L., Townsend, R. R., & Muntner, P. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1270 · Cited by 190
“Also, the amount of reimbursement for ABPM is low (4, 67).”
Self-citationKronish, I. M., Kent, S., Moise, N., Shimbo, D., Safford, M. M., Kynerd, R. E., O'Beirne, R., Sullivan, A., & Muntner, P. (2017) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2017.06.012 · Cited by 145
Self-citationAnstey, D. E., Muntner, P., Bello, N. A., Pugliese, D. N., Yano, Y., Kronish, I. M., Reynolds, K., Schwartz, J. E., & Shimbo, D. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11319 · Cited by 85
Self-citationBello, N. A., Schwartz, J. E., Kronish, I. M., Oparil, S., Anstey, D. E., Wei, Y., Cheung, Y. K. K., Muntner, P., & Shimbo, D. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.008658 · Cited by 42
Self-citationMeasuring and managing blood pressure in a primary care setting: a pragmatic implementation study
Doane, J., Buu, J., Penrod, M. J., Bischoff, M., Conroy, M. B., & Stults, B. (2018) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.2018.03.170450 · Cited by 23
“However, ABPM is infrequently used in the United States 12 due to limited availability 13 and reimbursement 14,15 and clinician unfamiliarity with its utility.”
Background
Metadata
- Authors
- Kent, S. T., Shimbo, D., Huang, L., Diaz, K. M., Viera, A. J., Kilgore, M., Oparil, S., & Muntner, P.
- Venue
- Journal of the American Society of Hypertension
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 8
- Issue
- 12
- Pages
- 898-908
- ISSN
- 1878-7436 (ISSN-L)
- 1933-1711
- OpenAlex
- W2021441380
- Cited by
- 41
- References
- 6
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.