CoChat

Construction of a hybrid quadrupole/fourier transform ion cyclotron resonance mass spectrometer for versatile MS/MS above 10 kDa

Patrie, Steven M., Charlebois, Jay P., Whipple, David, Kelleher, Neil L., Hendrickson, Christopher L., Quinn, John P., Marshall, Alan G., Mukhopadhyay, Biswarup · 2004 · Journal of the American Society for Mass Spectrometry
Cited by 114

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Technological advancements including an open-cylindrical Penning trap with capacitively coupled ICR cell, selective ion accumulation with a resolving quadrupole, and a voltage gradient used during ion extraction from an octopole ion trap, have individually improved dynamic range and sensitivity in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS). Documented here is a new instrument utilizing these technologies toward the robust detection and fragmentation of biomolecules >10 kDa. Up to 55-fold enhancement in ion population by selective ion accumulation combined with 10- to 20- fold signal-to-noise improvement by application of a DC voltage gradient to an accumulation octopole during the ion transfer event offers improved signal-to-noise (or speed) of MS/MS experiments, for proteins from Methanococcus jannaschii and Saccharomyces cerevisiae whole cell lysates. After external quadrupole filtering with a 40 m/z window, three proteins were fragmented (and identified) in parallel from the database of Methanococcus jannaschii. Electron capture dissociation (ECD) of an intact yeast protein provides extensive sequence information resulting in a high degree of localization for an N-terminal acetylation. Hybrid fragmentation, infrared multiphoton dissociation (IRMPD) followed by low energy electrons (ECD), with the electron source located laterally off the z-axis and external to the magnet bore, presents a strategy for identification of proteins by means of the sequence tag approach. Automated implementation of diverse MS(n) approaches in a Q-FTMS instrument promises to help realize "top-down" proteomics in the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jasms.2004.04.031

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 114

Metadata

Authors
Patrie, S. M., Charlebois, J. P., Whipple, D., Kelleher, N. L., Hendrickson, C. L., Quinn, J. P., Marshall, A. G., & Mukhopadhyay, B.
Venue
Journal of the American Society for Mass Spectrometry
Published
2004-07-01
Volume
15
Issue
7
Pages
1099-1108
ISSN
1044-0305 (ISSN-L)
OpenAlex
W2028332469
Cited by
114
References
3
FWCI
9.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Construction of a hybrid quadrupole/fourier transform ion cyclotron resonance mass spectrometer for versatile MS/MS above 10 kDa. https://app.cochat.ai/papers/10.1016/j.jasms.2004.04.031
The paper
Patrie, S. M., Charlebois, J. P., Whipple, D., Kelleher, N. L., Hendrickson, C. L., Quinn, J. P., Marshall, A. G., & Mukhopadhyay, B. (2004). Construction of a hybrid quadrupole/fourier transform ion cyclotron resonance mass spectrometer for versatile MS/MS above 10 kDa. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2004.04.031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.