Targeted data acquisition for improved reproducibility and robustness of proteomic mass spectrometry assays
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Quantitative mass spectrometry-based proteomic assays often suffer from a lack of robustness and reproducibility. We here describe a targeted mass spectrometric data acquisition strategy for affinity enriched subproteomes-in our case the kinome-that enables a substantially improved reproducibility of detection, and improved quantification via isobaric tags. Inclusion mass lists containing m/z, charge state, and retention time were created based on a set of 80 shotgun-type experiments performed under identical experimental conditions. For each target protein, peptides were selected according to their frequency of observation and isobaric tag for relative and absolute quantitation (iTRAQ) reporter ion quality. Retention times of selected peptides were aligned using similarity driven pairwise alignment strategy yielding <1 min standard deviation for 4 h gradients. Multiple fragmentation of the same peptides resulted in better statistics and more precise reporter ion based quantification without any loss in coverage. Overall, 24% more target proteins were quantified using the targeted data acquisition approach, and precision of quantification improved by >1.5-fold. We also show that a combination of higher energy collisional dissociation (HCD) with collisional induced dissociation (CID) outperformed pulsed-Q-dissociation (PQD) on the OrbitrapXL. With the CID/HCD based targeted data acquisition approach 10% more quantifiable target proteins were identified and a 2-fold increase in quantification precision was achieved. We have observed excellent reproducibility between different instruments, underlining the robustness of the approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925
Activity-Based Protein Profiling: From Enzyme Chemistry to Proteomic Chemistry
Cravatt, B. F., Wright, A. T., & Kozarich, J. W. (2008) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.75.101304.124125 · Cited by 1,270
Desiere, F. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkj040 · Cited by 910
A dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464 · cited 1×
“Experiments were performed on Thermo LTQ Orbitrap XL and Thermo LTQ Orbitrap Velos [ 13 ] mass spectrometers that were coupled to split-less Eksigent NanoLCs (Dublin, CA, USA).”
Method
Cited by
Catalytic in vivo protein knockdown by small-molecule PROTACs
Bondeson, D. P., Mares, A., Smith, I. E. D., Ko, E., Campos, S., Miah, A. H., Mulholland, K. E., Routly, N., Buckley, D. L., Gustafson, J. L., et al. (2015) · Nature Chemical Biology · doi:10.1038/nchembio.1858 · Cited by 1,356
Self-citationTracking cancer drugs in living cells by thermal profiling of the proteome
Savitski, M. M., Reinhard, F. B. M., Franken, H., Werner, T., Savitski, M. F., Eberhard, D., Molina, D. M., Jafari, R., Dovega, R. B., Klaeger, S., et al. (2014) · Science · doi:10.1126/science.1255784 · Cited by 1,187
Self-citationQuantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
Self-citationChemoproteomics profiling of HDAC inhibitors reveals selective targeting of HDAC complexes
Bantscheff, M., Hopf, C., Savitski, M. M., Dittmann, A., Grandi, P., Michon, A.-M., Schlegl, J., Abraham, Y., Becher, I., Bergamini, G., et al. (2011) · Nature Biotechnology · doi:10.1038/nbt.1759 · Cited by 659
Self-citationFranken, H., Mathieson, T., Childs, D., Sweetman, G. M. A., Werner, T., Tögel, I., Doce, C., Gade, S., Bantscheff, M., Drewes, G., et al. (2015) · Nature Protocols · doi:10.1038/nprot.2015.101 · Cited by 659
Self-citation
Metadata
- Authors
- Savitski, M. M., Fischer, F., Mathieson, T., Sweetman, G., Lang, M., & Bantscheff, M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-01
- Volume
- 21
- Issue
- 10
- Pages
- 1668-1679
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2052802848
- Cited by
- 88
- References
- 4
- FWCI
- 4.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Targeted data acquisition for improved reproducibility and robustness of proteomic mass spectrometry assays. https://app.cochat.ai/papers/10.1016/j.jasms.2010.01.012
- The paper
- Savitski, M. M., Fischer, F., Mathieson, T., Sweetman, G., Lang, M., & Bantscheff, M. (2010). Targeted data acquisition for improved reproducibility and robustness of proteomic mass spectrometry assays. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2010.01.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.