The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Compressive fatigue behavior of human vertebral trabecular bone
Abstract
Damage accumulation under compressive fatigue loading is believed to contribute significantly to non-traumatic, age-related vertebral fractures in the human spine. Only few studies have explored trabecular bone fatigue behavior under compressive loading and none examined the influence of trabecular architecture on fatigue life. In this study, trabecular bone samples of human lumbar and thoracic vertebrae (4 donors from age 29 to 86, n=29) were scanned with a microCT system prior to compressive fatigue testing to determine morphology-mechanical relationships for this relevant loading mode. Inspired from previous fabric-based relationships for elastic properties and quasi-static strength of trabecular bone, a simple power relationship between volume fraction, fabric eigenvalue, applied stress and the number of cycles to failure is proposed. The experimental results demonstrate a high correlation for this relationship (R2=0.95) and detect a significant contribution of the degree of anisotropy towards prediction of fatigue life. Step-wise regression for total and residual strains at failure suggested a weak, but significant correlation with volume fraction. From the obtained results, we conclude that the applied stress normalized by volume fraction and axial fabric eigenvalue can estimate fatigue life of human vertebral trabecular bone in axial compressive loading.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The number of cycles to failure in human vertebral trabecular bone is well predicted by a power-law relationship in which the independent variables are volume fraction, fabric, and applied stress, and a significant contribution of the degree of anisotropy toward the prediction of fatigue life has been observed (117).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [117]
In the citing paper
“The number of cycles to failure in human vertebral trabecular bone is well predicted by a power-law relationship in which the independent variables are volume fraction, fabric, and applied stress, and a significant contribution of the degree of anisotropy toward the prediction of fatigue life has been observed (117).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [117]
Citations
Cites
The worldwide problem of osteoporosis: Insights afforded by epidemiology
Riggs, B. L., & Melton, L. J. (1995) · Bone · doi:10.1016/8756-3282(95)00258-4 · Cited by 1,414
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Ruegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Wettability and spreading kinetics of molten aluminum on copper-coated ceramics
León-Patiño, C. A., Mendoza-Suarez, G., & Drew, R. A. L. (2006) · Journal of Materials Science · doi:10.1007/s10853-006-0443-7 · Cited by 899
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 807
Yield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 654
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 610
Bone creep-fatigue damage accumulation
Caler, W. E., & Carter, D. R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90013-4 · Cited by 263
A review of morphology–elasticity relationships in human trabecular bone: theories and experiments
Zysset, P. K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00128-3 · Cited by 223
Self-citationLaib, A., Barou, O., Vico, L., Lafage‐Proust, M., Alexandre, C., & Ruegsegger, P. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347054 · Cited by 203
Recognizing and reporting osteoporotic vertebral fractures
Grigoryan, M., Guermazi, A., Roemer, F. W., Delmas, P. D., & Genant, H. K. (2003) · European Spine Journal · doi:10.1007/s00586-003-0613-0 · Cited by 201
Research works printed but not linked: 1
- Rapillard, L., 2002. Vertebroplasty. Diploma Thesis, École Polytechnique Fédérale de Lausanne, Lausanne.
Cited by
Sorted by citations
Nature’s hierarchical materials
Fratzl, P., & Weinkamer, R. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2007.06.001 · Cited by 2,788
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“The number of cycles to failure in human vertebral trabecular bone is well predicted by a power-law relationship in which the independent variables are volume fraction, fabric, and applied stress, and a significant contribution of the degree of anisotropy toward the prediction of fatigue life has been observed (117).”
Popp, A. W., Zysset, P. K., & Lippuner, K. (2015) · Osteoporosis International · doi:10.1007/s00198-015-3458-6 · Cited by 163
Self-citationCumulative mechanical low-back load at work is a determinant of low-back pain
Coenen, P., Kingma, I., Boot, C. R. L., Bongers, P. M., & van Dieën, J. H. (2014) · Occupational and Environmental Medicine · doi:10.1136/oemed-2013-101862 · Cited by 148
Standardizing compression testing for measuring the stiffness of human bone
Zhao, S., Arnold, M. C. A., Ma, S., Abel, R., Cobb, J. P., Hansen, U., & Boughton, O. R. (2018) · Bone and Joint Research · doi:10.1302/2046-3758.78.bjr-2018-0025.r1 · Cited by 122
Bone fatigue and its implications for injuries in racehorses
Martig, S., Chen, W., Lee, P. V. S., & Whitton, R. C. (2014) · Equine Veterinary Journal · doi:10.1111/evj.12241 · Cited by 124
Density and mechanical properties of vertebral trabecular bone—A review
Öhman‐Mägi, C., Holub, O., Wu, D., Hall, R. M., & Persson, C. (2021) · JOR Spine · doi:10.1002/jsp2.1176 · Cited by 114
Harrison, S. M., Whitton, R. C., Kawcak, C. E., Stover, S. M., & Pandy, M. G. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.10.001 · Cited by 108
van Lenthe, H., Stauber, M., & Müller, R. (2006) · Bone · doi:10.1016/j.bone.2006.06.033 · Cited by 89
Fatigue behaviour of load-bearing polymeric bone scaffolds: A review
Bakhtiari, H., Nouri, A., Khakbiz, M., & Tolouei‐Rad, M. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.09.048 · Cited by 82
Anisotropy of the fatigue behaviour of cancellous bone
Dendorfer, S., Maier, H. J., Taylor, D., & Hammer, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.037 · Cited by 76
Subchondral bone microdamage accumulation in distal metacarpus of Thoroughbred racehorses
Whitton, R. C., Ayodele, B. A., Hitchens, P. L., & Mackie, E. J. (2018) · Equine Veterinary Journal · doi:10.1111/evj.12948 · Cited by 73
Fatigue of biomaterials: Hard tissues
Arola, D. D., Bajaj, D., Ivancik, J., Majd, H., & Zhang, D. (2009) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2009.08.007 · Cited by 70
Follet, H., Viguet‐Carrin, S., Burt‐Pichat, B., Dépalle, B., Bala, Y., Gineyts, É., Munoz, F., ARLOT, M. E., Boivin, G., Chapurlat, R. D., et al. (2010) · Journal of Orthopaedic Research® · doi:10.1002/jor.21275 · Cited by 79
Apparent damage accumulation in cancellous bone using neural networks
Hambli, R. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.03.002 · Cited by 63
Development of the fetal ilium – challenging concepts of bipedality
Cunningham, C. A., & Black, S. M. (2008) · Journal of Anatomy · doi:10.1111/j.1469-7580.2008.01005.x · Cited by 54
Influence of geometry on proximal femoral shaft strains: Implications for atypical femoral fracture
Haider, I. T., Schneider, P., Michalski, A. S., & Edwards, W. B. (2018) · Bone · doi:10.1016/j.bone.2018.02.015 · Cited by 52
Hambli, R. (2011) · Finite Elements in Analysis and Design · doi:10.1016/j.finel.2011.02.014 · Cited by 51
Permeability study of cancellous bone and its idealised structures
Syahrom, A., Kadir, M. R. A., Harun, M. N., & Öchsner, A. Ö. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.11.001 · Cited by 43
Continuum damage interactions between tension and compression in osteonal bone
Mirzaali, M. J., Bürki, A., Schwiedrzik, J. J., Zysset, P. K., & Wolfram, U. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.05.007 · Cited by 41
Self-citationCompressive fatigue life of subchondral bone of the metacarpal condyle in thoroughbred racehorses
Martig, S., Lee, P. V. S., Anderson, G. A., & Whitton, R. C. (2013) · Bone · doi:10.1016/j.bone.2013.09.006 · Cited by 39
Mechanical properties of open-cell foam synthetic thoracic vertebrae
Johnson, A. E., & Keller, T. S. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3158-7 · Cited by 39
Hambli, R. (2010) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.1413 · Cited by 38
Syahrom, A., Kadir, M. R. A., Abdullah, J. B., & Öchsner, A. Ö. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0833-0 · Cited by 38
Integrated remodeling-to-fracture finite element model of human proximal femur behavior
Hambli, R., Lespessailles, É., & Benhamou, C.-L. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.08.011 · Cited by 35
Bakhtiari, H., Nouri, A., & Tolouei‐Rad, M. (2024) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2024.108420 · Cited by 33
On the effect of marrow in the mechanical behavior and crush response of trabecular bone
Halgrin, J., Chaari, F., & Markiewicz, É. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.09.003 · Cited by 33
Coenen, P., Kingma, I., Boot, C. R. L., Bongers, P. M., & van Dieën, J. H. (2012) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2012.07.010 · Cited by 33
Trope, G. D., Ghasemzadeh, A., Anderson, G. A., Mackie, E. J., & Whitton, R. C. (2014) · Equine Veterinary Journal · doi:10.1111/evj.12312 · Cited by 30
Compressive fatigue and fracture toughness behavior of injectable, settable bone cements
Harmata, A. J., Uppuganti, S., Granke, M., Guelcher, S. A., & Nyman, J. S. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.07.027 · Cited by 29
Boccaccio, A., Vena, P., Gastaldi, D., Franzoso, G., Pietrabissa, R., & Pappalettere, C. (2008) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim296 · Cited by 29
Bone: A Composite Natural Material
Fatima, M., Canhão, H. M., & Eurico, J. (2011) · InTech eBooks · doi:10.5772/17523 · Cited by 30
Effect of torsional loading on compressive fatigue behaviour of trabecular bone
Januddi, F., Rabiatul, A. A. R., Harun, M. N., Kadir, M. R. A., Kamarul, T., & Syahrom, A. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.09.006 · Cited by 28
Exercise-induced inhibition of remodelling is focally offset with fatigue fracture in racehorses
Whitton, R. C., Mirams, M., Mackie, E. J., Anderson, G. A., & Seeman, E. (2013) · Osteoporosis International · doi:10.1007/s00198-013-2291-z · Cited by 28
Haider, I. T., Lee, M., Page, R., Smith, D. B., & Edwards, W. B. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110434 · Cited by 27
The evolving role of biomechanics in prevention of overexertion injuries
Chaffin, D. B. (2009) · Ergonomics · doi:10.1080/00140130802479812 · Cited by 27
Time Dependent Behaviour of Trabecular Bone at Multiple Load Levels
Xie, S., Manda, K., Wallace, R. J., Levrero-Florencio, F., Simpson, H., & Pankaj, P. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1800-1 · Cited by 26
Martig, S., Hitchens, P. L., Lee, P. V. S., & Whitton, R. C. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103439 · Cited by 26
Martínez‐Reina, J., Calvo‐Gallego, J. L., & Pivonka, P. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.635056 · Cited by 27
Arabmotlagh, M., Bachmaier, S., Geiger, F., & Rauschmann, M. (2014) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33140 · Cited by 25
Martig, S., Hitchens, P. L., Stevenson, M. A., & Whitton, R. C. (2018) · Journal of Anatomy · doi:10.1111/joa.12794 · Cited by 25
Ergun, A., Chung, R., Ward, D., Valdevit, A. D. C., Ritter, A., & Kalyon, D. M. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0484-1 · Cited by 21
Brouwers, J. E. M., Ruchelsman, M., van Rietbergen, B., & Bouxsein, M. (2008) · Osteoporosis International · doi:10.1007/s00198-008-0803-z · Cited by 21
Parkinson, R., & Callaghan, J. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.007 · Cited by 21
Putra, N. E., Moosabeiki, V., Leeflang, M. A., Zhou, J., & ZADPOOR, A. A. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.02.024 · Cited by 20
Slatkovska, L., Beyene, J., Alibhai, S. M. H., Wong, Q., Sohail, Q. Z., & Cheung, A. M. (2014) · Calcified Tissue International · doi:10.1007/s00223-014-9920-1 · Cited by 19
Biologic Foundations for Skeletal Tissue Engineering
Bueno, E. M., & Glowacki, J. (2011) · Synthesis lectures on tissue engineering · doi:10.1007/978-3-031-02583-9 · Cited by 21
Maquer, G., Bürki, A., Nuss, K. M. R., Zysset, P. K., & Tannast, M. (2016) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-016-5024-8 · Cited by 17
Self-citationPanagiotopoulou, V. C., Ovesy, M., Gueorguiev, B. G., Richards, R. G., Zysset, P. K., & Varga, P. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104344 · Cited by 16
Self-citationTopoliński, T., Cichański, A., Mazurkiewicz, A., & Nowicki, K. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.05.032 · Cited by 16
The effect of trabecular bone storage method on its elastic properties
Mazurkiewicz, A. (2018) · PubMed · doi:10.5277/abb-00967-2017-03 · Cited by 15
Pye, J. L., Spriet, M. P., O'Brion, J., Carpenter, R., Blea, J. A., & Dowd, J. P. (2022) · American Journal of Veterinary Research · doi:10.2460/ajvr.22.03.0062 · Cited by 14
From Tension to Compression: Asymmetric Mechanical Behaviour of Trabecular Bone’s Organic Phase
Xie, S., Wallace, R. J., Callanan, A., & Pankaj, P. (2018) · Annals of Biomedical Engineering · doi:10.1007/s10439-018-2009-7 · Cited by 14
Walschot, L., Schreurs, B. W., Buma, P., & Verdonschot, N. J. J. (2010) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31692 · Cited by 14
Mathematical modelling of bone adaptation of the metacarpal subchondral bone in racehorses
Hitchens, P. L., Pivonka, P., Malekipour, F., & Whitton, R. C. (2018) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-017-0998-z · Cited by 14
Fatigue Energy Dissipation in Trabecular Bone Samples with Stepwise-Increasing Amplitude Loading*
Topoliński, T., Cichański, A., Mazurkiewicz, A., & Nowicki, K. (2011) · Materials Testing · doi:10.3139/120.110235 · Cited by 13
Topoliński, T., Cichański, A., Mazurkiewicz, A., & Nowicki, K. (2012) · The Scientific World JOURNAL · doi:10.1100/2012/827196 · Cited by 12
Hambli, R., & Hattab, N. (2012) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/8415_2012_146 · Cited by 11
Topoliński, T., Cichański, A., Mazurkiewicz, A., & Nowicki, K. (2012) · Materials science forum · doi:10.4028/www.scientific.net/msf.726.39 · Cited by 10
Creating Physiologically Realistic Vertebral Fractures in a Cervine Model
Corbiere, N. C., Lewicki, K. A., Issen, K. A., & Kuxhaus, L. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4027059 · Cited by 8
Biologic Foundations for Skeletal Tissue Engineering
Bueno, E., & Glowacki, J. (2011) · Synthesis lectures on tissue engineering · doi:10.2200/s00329ed1v01y201101tis007 · Cited by 25
Purcell, P., Tiernan, S., McEvoy, F., & Morris, S. F. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.03.014 · Cited by 8
Koshyk, A., Pohl, A. J., Takahashi, Y., Scott, W. M., Sparks, H. D., & Edwards, W. B. (2024) · Bone · doi:10.1016/j.bone.2024.117054 · Cited by 7
Liang, T., Gao, C., Yang, L., Saijilafu, Yang, H., & Luo, Z. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.07.026 · Cited by 7
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 6
Mechanical Behaviour of Cancellous bone: Compression and Three-Point Bending Test
Ghazali, F. A. M., & Syahrom, A. (2022) · Malaysian Journal of Fundamental and Applied Sciences · doi:10.11113/mjfas.v18n3.2274 · Cited by 5
Relationship between morphological parameters of cancellous bone and its mechanical properties
Syahrom, A., Kadir, M. R. A., & Muslim, D. A.-J. (2010) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2010.5742256 · Cited by 5
Mouss, M. E., Zellagui, S., Nasraoui, M., & Hambli, R. (2020) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411920924509 · Cited by 5
The developing juvenile ischium: Macro‐radiographic insights
Maclean, S. J., Black, S. M., & Cunningham, C. A. (2014) · Clinical Anatomy · doi:10.1002/ca.22391 · Cited by 5
Kim, J., & Kim, J. J. (2024) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3845 · Cited by 4
Bo, L., Xu, C., Li, W., Lu, D., & Jin, Z. M. (2021) · Acta of Bioengineering and Biomechanics · doi:10.37190/abb-01834-2021-02 · Cited by 4
Accelerated Method for Determining the Fatigue Limit of Trabecular Bone
Cichański, A., Topoliński, T., & Nowicki, K. (2025) · Materials · doi:10.3390/ma18020232 · Cited by 3
Li, N., Cavagnaro, M. J., Xiong, K., Du, X., & Shi, J. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.700148 · Cited by 3
A Novel Approach to Predict the Location and Fatigue Life of Intervertebral Disc Degeneration
Zhang, Z., Wang, T. X., Bian, H., Shen, X. Q., Liang, M., Teo, E.-C., & Jiang, T. (2025) · Bioengineering · doi:10.3390/bioengineering12040423 · Cited by 3
Frigelli, M., Mischler, D., Indermaur, M., Wili, P., Dolati, A., Kessler, F., Tenisch, L., Hüsken, L., Spruit, M., Varga, P., et al. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.107167 · Cited by 3
Self-citationBerger, L., Eichler, J., Ryll, E. J. S., Fischerauer, S., Raschke, M. C. E. J., Kolbitsch, A., Castellani, C., & Weinberg, A. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.05.122 · Cited by 3
Optimization of 3D printing parameters for PLGA/HA scaffolds using the Taguchi method
Gautam, K., Jimenez, H. G., Dikici, Y., Bensusan, J. S., Wnek, G. E., Rimnac, C. M., & Akkuş, O. (2026) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2026.107385 · Cited by 2
Fatigue performance of additively manufactured porous titanium for orthopaedic applications
Leinwand, J., Lam, R., Patel, S. R., McGregor, M. E., McLachlin, S. D., & Vlasea, M. (2026) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2026.107393 · Cited by 2
Coenen, P. (2013) · Digital Academic REpository of VU University Amsterdam (Vrije Universiteit Amsterdam) · doi:10.13140/2.1.1978.2082 · Cited by 2
Fatigue behavior of trabecular bone orientationPreprint
Januddi, F., Harun, M. N., Abdullah, J., Mostakhdemin, M., & Syahrom, A. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.02.12.945352 · Cited by 2
Mechanical and morphometric characterization of cancellous bone
González, R. B. (2020) · doi:10.4995/thesis/10251/149376 · Cited by 2
Sacher, S. E., Hernandez, C. J., & Donnelly, E. L. (2021) · Advanced Engineering Materials · doi:10.1002/adem.202100206 · Cited by 1
Probability of fatigue failure and minimum sample size requirements for cyclically loaded bone
Koshyk, A., Pohl, A. J., Firminger, C. R., & Edwards, W. B. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.107061 · Cited by 1
GENG, Y., Wang, T. X., XU, C., Bian, H., Shen, X. Q., Teo, E.-C., & Jiang, T. (2024) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519424500180 · Cited by 1
Method of Determining the Initial Stiffness Modulus for Trabecular Bone under Stepwise Load
Topoliński, T., Cichański, A., Mazurkiewicz, A., & Nowicki, K. (2012) · Materials science forum · doi:10.4028/www.scientific.net/msf.726.84 · Cited by 1
Influence of the trabecular bone structure indicators on its static and fatigue strengths
Mazurkiewicz, A. (2017) · OpenstarTs (Univeristy of Trieste https://www.units.it/) · Cited by 1
QCT-based computational bone strength assessment updated with MRI-derived ‘hidden’ microporosity
McPhee, S., Kershaw, L. E., Daniel, C. R., Fernández, M. P., Cillán‐García, E., Taylor, S. E., & Wolfram, U. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.106094 · Cited by 1
Bone Mass Preservation and Fracture Risk Assessment with Bisphosphonate Therapy During Spaceflight
Gardina, C. (2008) · DigitalCommons - CalPoly (California State Polytechnic University) · doi:10.15368/theses.2008.18
In vivo assessment of changes in bone due to osteoporosis and its possible treatments
Huiskes, H. W. J., Ito, K., & Brouwers, J. E. M. (2004)
Fatigue and Creep Failure in Musculoskeletal Tissues
Taylor, D. M. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.00961-9
Parkinson, R. (2008) · UWSpace (University of Waterloo)
Stock, S. R. (2019) · CRC Press eBooks · doi:10.1201/9780429186745-8
Characterisation of Hydrogel Scaffolds Under Compression
Tong, J., Hsu, Y.-C., Madi, K., Cossey, A. J., & Au, A. (2016) · Springer series in biomaterials science and engineering · doi:10.1007/978-3-662-53574-5_11
Effects of Gamma Irradiation on the Damage Processes in Human Trabecular Bone
Ramsey, D. S. (2010) · OhioLink ETD Center (Ohio Library and Information Network)
Simulation of the fatigue performance of spinal vertebrae
Coe, R. H. (2018) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Monotonic and cyclic behaviour of trabecular bone under uniaxial and multiaxial loading
Januddi, M. S., & Januddi, M. A. F. M. S. (2015)
NUMERICAL ANALYSIS ON FATIGUE LIFE PREDICTION OF CANCELLOUS BONE RESPECT TO NORMAL WALKING LOADING
Mostakhdemin, M., S.J, F. S. J. F., Harun, M. N., & Syahrom, A. (2015) · Jurnal MEKANIKAL
Applicability of Indicators of Trabecular Bone Structure for Evaluation of its Mechanical Properties
Cichański, A., Nowicki, K., Mazurkiewicz, A., & Topoliński, T. (2012) · Acta Mechanica et Automatica
Effect of Including Periodic Boundary Condition on the Fatigue Behaviour of Cancellous Bone
Januddi, F., Harun, M. N., Syahrom, A., Bakri, A., & Alkbir, M. F. M. (2020) · International Journal of Integrated Engineering · doi:10.30880/ijie.2020.12.05.009
Metadata
- Authors
- Rapillard, L., Charlebois, M., & Zysset, P. K.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- TU Wien (AT)
- Corresponding author
- Zysset, Philippe K.
- ORCID
- Zysset, Philippe K.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2006
- Volume
- 39
- Issue
- 11
- Pages
- 2133-2139
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2018114205
- Cited by
- 113
- References
- 23
- Citations by year
- 2026: 7 · 2025: 5 · 2024: 6 · 2023: 2 · 2022: 2 · 2021: 10 · 2020: 4 · 2019: 2 · 2018: 9 · 2017: 4 · 2016: 3 · 2015: 8 · 2014: 8 · 2013: 4 · 2012: 9
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Mechanics of Materials › Fatigue and fracture mechanics
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Keywords
- trabecular bone, compressive fatigue, fatigue life prediction, vertebral fractures, lumbar vertebrae, thoracic vertebrae, trabecular bone microarchitecture, anisotropy, volume fraction, residual strain, micro-CT, spine
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biomechanical Phenomena, Humans, Middle Aged, Spine, Compressive Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review