The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Compressive fatigue behavior of human vertebral trabecular bone
Abstract
Damage accumulation under compressive fatigue loading is believed to contribute significantly to non-traumatic, age-related vertebral fractures in the human spine. Only few studies have explored trabecular bone fatigue behavior under compressive loading and none examined the influence of trabecular architecture on fatigue life. In this study, trabecular bone samples of human lumbar and thoracic vertebrae (4 donors from age 29 to 86, n=29) were scanned with a microCT system prior to compressive fatigue testing to determine morphology-mechanical relationships for this relevant loading mode. Inspired from previous fabric-based relationships for elastic properties and quasi-static strength of trabecular bone, a simple power relationship between volume fraction, fabric eigenvalue, applied stress and the number of cycles to failure is proposed. The experimental results demonstrate a high correlation for this relationship (R2=0.95) and detect a significant contribution of the degree of anisotropy towards prediction of fatigue life. Step-wise regression for total and residual strains at failure suggested a weak, but significant correlation with volume fraction. From the obtained results, we conclude that the applied stress normalized by volume fraction and axial fabric eigenvalue can estimate fatigue life of human vertebral trabecular bone in axial compressive loading.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The number of cycles to failure in human vertebral trabecular bone is well predicted by a power-law relationship in which the independent variables are volume fraction, fabric, and applied stress, and a significant contribution of the degree of anisotropy toward the prediction of fatigue life has been observed (117).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [117]
In the citing paper
“The number of cycles to failure in human vertebral trabecular bone is well predicted by a power-law relationship in which the independent variables are volume fraction, fabric, and applied stress, and a significant contribution of the degree of anisotropy toward the prediction of fatigue life has been observed (117).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [117]
Citations
Cites
The worldwide problem of osteoporosis: Insights afforded by epidemiology
Riggs, B. L., & Melton, L. J. (1995) · Bone · doi:10.1016/8756-3282(95)00258-4 · Cited by 1,414
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Ruegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Wettability and spreading kinetics of molten aluminum on copper-coated ceramics
León-Patiño, C. A., Mendoza-Suarez, G., & Drew, R. A. L. (2006) · Journal of Materials Science · doi:10.1007/s10853-006-0443-7 · Cited by 899
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 807
Yield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 654
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 610
Bone creep-fatigue damage accumulation
Caler, W. E., & Carter, D. R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90013-4 · Cited by 263
A review of morphology–elasticity relationships in human trabecular bone: theories and experiments
Zysset, P. K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00128-3 · Cited by 223
Self-citationLaib, A., Barou, O., Vico, L., Lafage‐Proust, M., Alexandre, C., & Ruegsegger, P. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347054 · Cited by 203
Recognizing and reporting osteoporotic vertebral fractures
Grigoryan, M., Guermazi, A., Roemer, F. W., Delmas, P. D., & Genant, H. K. (2003) · European Spine Journal · doi:10.1007/s00586-003-0613-0 · Cited by 201
Flagged first, then by citations
Research works printed but not linked: 1
- Rapillard, L., 2002. Vertebroplasty. Diploma Thesis, École Polytechnique Fédérale de Lausanne, Lausanne.
Cited by
Sorted by citations
Items 101–113 of 113
A combined experimental and computational study of mechanical properties after balloon kyphoplasty
Purcell, P., McEvoy, F., Tiernan, S., Sweeney, D., & Morris, S. F. (2021) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119211013927
(2008) · CRC Press eBooks · doi:10.1201/9781420058772.ch8
Tolouei‐Rad, M., Bakhtiari, H., & Nouri, A. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4777401
Ghazali, F. A. M., Rianti, D., Basri, H., Prakoso, A. T., Yulianti, A., Kadir, M. R. A., Kamarul, T., Öchsner, A. Ö., & Syahrom, A. (2025) · Proceedings of the Institution of Mechanical Engineers Part L Journal of Materials Design and Applications · doi:10.1177/14644207251325995
Lai, R., Lü, Y., Li, J., Liu, X., Feng, L., Wang, L., & Shu, L. (2026) · Annals of Biomedical Engineering · doi:10.1007/s10439-026-04202-w
Aldowah, O., Zarbah, M., Aseri, A. A., Almeshari, A. A., El-Anwar, M. I., Emam, A.-N. M., & Alharthi, H. (2026) · BMC Oral Health · doi:10.1186/s12903-026-07678-z
Osteoporosis and osteoporotic fractures
Galbusera, F., & Wilke, H.-J. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-26568-6.00019-9
Comparative Fatigue Analysis of CF-PLA Metamaterial Bone Plates for Orthopaedic Fixation
Daniel, A., Bakhtiari, H., Das, B. K., Aamir, M., & Tolouei‐Rad, M. (2026) · Polymers · doi:10.3390/polym18101152
Li, H., Deng, T., Huang, Z., Zhu, K., Gong, S., & Nie, Y. (2026) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2026.08.096
Metadata
- Authors
- Rapillard, L., Charlebois, M., & Zysset, P. K.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- TU Wien (AT)
- Corresponding author
- Zysset, Philippe K.
- ORCID
- Zysset, Philippe K.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2006
- Volume
- 39
- Issue
- 11
- Pages
- 2133-2139
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2018114205
- Cited by
- 113
- References
- 23
- Citations by year
- 2026: 7 · 2025: 5 · 2024: 6 · 2023: 2 · 2022: 2 · 2021: 10 · 2020: 4 · 2019: 2 · 2018: 9 · 2017: 4 · 2016: 3 · 2015: 8 · 2014: 8 · 2013: 4 · 2012: 9
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Mechanics of Materials › Fatigue and fracture mechanics
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Keywords
- trabecular bone, compressive fatigue, fatigue life prediction, vertebral fractures, lumbar vertebrae, thoracic vertebrae, trabecular bone microarchitecture, anisotropy, volume fraction, residual strain, micro-CT, spine
- MeSH terms
- Adult, Aged, Aged, 80 and over, Biomechanical Phenomena, Humans, Middle Aged, Spine, Compressive Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review