Modeling of cardiac muscle thin films: Pre-stretch, passive and active behavior
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Recent progress in tissue engineering has made it possible to build contractile bio-hybrid materials that undergo conformational changes by growing a layer of cardiac muscle on elastic polymeric membranes. Further development of such muscular thin films for building actuators and powering devices requires exploring several design parameters, which include the alignment of the cardiac myocytes and the thickness/Young’s modulus of elastomeric film. To more efficiently explore these design parameters, we propose a 3-D phenomenological constitutive model, which accounts for both the passive deformation including pre-stretch and the active behavior of the cardiomyocytes. The proposed 3-D constitutive model is implemented within a finite element framework, and can be used to improve the current design of bio-hybrid thin films and help developing bio-hybrid constructs capable of complex conformational changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Finite element implementation of incompressible, transversely isotropic hyperelasticity
Weiss, J. A., Maker, B. N., & Govindjee, S. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(96)01035-3 · Cited by 797
Muscular Thin Films for Building Actuators and Powering Devices
Feinberg, A. W., Feigel, A., Shevkoplyas, S. S., Sheehy, S., Whitesides, G. M., & Parker, K. K. (2007) · Science · doi:10.1126/science.1146885 · Cited by 765 · cited 3×
“Contractile bio-hybrid materials have been built by growing a monolayer of spatially aligned cardiac myocytes on synthetic elastomeric thin films (Feinberg et al., 2007).”
Self-citationCell prestress. I. Stiffness and prestress are closely associated in adherent contractile cells
Wang, N., Tolić-Nørrelykke, I. M., Chen, J., Mijailovich, S. M., Butler, J. P., Fredberg, J. J., & Stamenović, D. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00269.2001 · Cited by 669 · cited 2×
“It is well known that the pre-stretch within the cells is largely affected by the substrate and the mechanical/chemical stimulus during maturation (Wang et al., 2002; Griffin et al., 2004; Engler et al., 2008).”
Sarcomere alignment is regulated by myocyte shape
Bray, M., Sheehy, S. P., & Parker, K. K. (2008) · Cell Motility · doi:10.1002/cm.20290 · Cited by 228
Self-citation
Cited by
Carbon-Nanotube-Embedded Hydrogel Sheets for Engineering Cardiac Constructs and Bioactuators
Shin, S. R., Jung, S. M., Zalabany, M., Kim, K., Zorlutuna, P., Kim, S. B., Nikkhah, M., Khabiry, M., Azize, M., Kong, J., et al. (2013) · ACS Nano · doi:10.1021/nn305559j · Cited by 946
“Furthermore, themechanically enforced scaffold could allow the fabrication and handling of ultrathin cardiac tissue patches, which are particularly suitable as cell delivery systems for cell therapy(15) and as soft actuators for in vitro biorobotic applications.(10,16)”
A tissue-engineered jellyfish with biomimetic propulsion
Nawroth, J. C., Lee, H., Feinberg, A. W., Ripplinger, C. M., McCain, M. L., Grosberg, A., Dabiri, J. O., & Parker, K. K. (2012) · Nature Biotechnology · doi:10.1038/nbt.2269 · Cited by 647
Self-citationBiohybrid actuators for robotics: A review of devices actuated by living cells
Ricotti, L., Trimmer, B., Feinberg, A. W., Raman, R., Parker, K. K., Bashir, R., Sitti, M., Martel, S., Dario, P., & Menciassi, A. (2017) · Science Robotics · doi:10.1126/scirobotics.aaq0495 · Cited by 527
Soft robotic sleeve supports heart function
Roche, E. T., Horvath, M. A., Wamala, I., Alazmani, A., Song, S.-E., Whyte, W., Machaidze, Z., Payne, C. J., Weaver, J. C., Fishbein, G., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf3925 · Cited by 425
Xiao, S., Zhao, T., Wang, J., Wang, C., Du, J., Ying, L., Lin, J., Zhang, C., Hu, W., Wang, L., et al. (2019) · Stem Cell Reviews and Reports · doi:10.1007/s12015-019-09893-4 · Cited by 363
Metadata
- Authors
- Shim, J., Grosberg, A., Nawroth, J. C., Kit Parker, K., & Bertoldi, K.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2012-03
- Volume
- 45
- Issue
- 5
- Pages
- 832-841
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1967052700
- Cited by
- 60
- References
- 4
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling of cardiac muscle thin films: Pre-stretch, passive and active behavior. https://app.cochat.ai/papers/10.1016/j.jbiomech.2011.11.024
- The paper
- Shim, J., Grosberg, A., Nawroth, J. C., Kit Parker, K., & Bertoldi, K. (2012). Modeling of cardiac muscle thin films: Pre-stretch, passive and active behavior. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2011.11.024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.