Accelerometer counts and raw acceleration output in relation to mechanical loading
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to assess the relationship of accelerometer output, in counts (ActiGraph GT1M) and as raw accelerations (ActiGraph GT3X+ and GENEA), with ground reaction force (GRF) in adults. Ten participants (age: 29.4 ± 8.2 yr, mass: 74.3 ± 9.8 kg, height: 1.76 ± 0.09 m) performed eight trials each of: slow walking, brisk walking, slow running, faster running and box drops. GRF data were collected for one step per trial (walking and running) using a force plate. Low jumps and higher jumps (one per second) were performed for 20 s each on the force plate. For box drops, participants dropped from a 35 cm box onto the force plate. Throughout, three accelerometers were worn at the hip: GT1M, GT3X+ and GENEA. A further GT3X+ and GENEA were worn on the left and right wrist, respectively. GT1M counts correlated with peak impact force (r = 0.85, p < 0.05), average resultant force (r = 0.73, p < 0.05) and peak loading rate (r = 0.76, p < 0.05). Accelerations from the GT3X+ and GENEA correlated with average resultant force and peak loading rate irrespective of whether monitors were worn at the hip or wrist (r > 0.82, p < 0.05, r > 0.63 p < 0.05, respectively). In conclusion, accelerometer count and raw acceleration output correlate positively with GRF and thus may be appropriate for the quantification of activity beneficial to bone. Wrist-worn monitors show a similar relationship with GRF as hip-worn monitors, suggesting that wrist-worn monitors may be a viable option for future studies looking at bone health.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“Validity of the accelerometer worn at the wrist is important as compliance is a major problem when collecting activity data using accelerometry; for example in the National Health and Nutrition Examination Survey in the US (2003–2004), only 26% of the sample had seven valid days of accelerometer wear (Troiano et al.,…”
MethodThe Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Self-citationValidation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 2×
“The ActiGraph GT1M (version 3, ActiGraph, Pensacola, USA) and GENEA accelerometers have been described in detail elsewhere (Esliger et al., 2011).”
MethodSelf-citationDirect measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Cited by
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers
FAIRCLOUGH, S. J., NOONAN, R., ROWLANDS, A. V., VAN HEES, V., KNOWLES, Z., & BODDY, L. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000771 · Cited by 300
Self-citationComparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents.
Scott, J. J., Rowlands, A. V., Cliff, D. P., Morgan, P. J., Plotnikoff, R. C., & Lubans, D. R. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.04.017 · Cited by 120
Self-citation
Metadata
- Authors
- Rowlands, A. V., & Stiles, V. H.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2012-02
- Volume
- 45
- Issue
- 3
- Pages
- 448-454
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2055472857
- Cited by
- 149
- References
- 5
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerometer counts and raw acceleration output in relation to mechanical loading. https://app.cochat.ai/papers/10.1016/j.jbiomech.2011.12.006
- The paper
- Rowlands, A. V., & Stiles, V. H. (2012). Accelerometer counts and raw acceleration output in relation to mechanical loading. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2011.12.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.