Experimental study of needle–tissue interaction forces: Effect of needle geometries, insertion methods and tissue characteristics
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
A thorough understanding of needle-tissue interaction mechanics is necessary to optimize needle design, achieve robotically needle steering, and establish surgical simulation system. It is obvious that the interaction is influenced by numerous variable parameters, which are divided into three categories: needle geometries, insertion methods, and tissue characteristics. A series of experiments are performed to explore the effect of influence factors (material samples n=5 for each factor) on the insertion force. Data were collected from different biological tissues and a special tissue-equivalent phantom with similar mechanical properties, using a 1-DOF mechanical testing system instrumented with a 6-DOF force/torque (F/T) sensor. The experimental results indicate that three basic phases (deformation, insertion, and extraction phase) are existent during needle penetration. Needle diameter (0.7-3.2mm), needle tip (blunt, diamond, conical, and beveled) and bevel angle (10-85°) are turned out to have a great influence on insertion force, so do the insertion velocity (0.5-10mm/s), drive mode (robot-assisted and hand-held), and the insertion process (interrupted and continuous). Different tissues such as skin, muscle, fat, liver capsule and vessel are proved to generate various force cures, which can contribute to the judgement of the needle position and provide efficient insertion strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sneddon, I. N. (1965) · International Journal of Engineering Science · doi:10.1016/0020-7225(65)90019-4 · Cited by 4,346
Force Modeling for Needle Insertion Into Soft Tissue
Okamura, A. M., Simone, C., & O'Leary, M. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831542 · Cited by 830 · cited 3×
“6 In order to build the insertion force model accurately, we make the needle-tissue interaction force divided into three parts: stiffness force, friction force, and cutting force (Okamura et al. 2004).”
MethodInfluentialNeedle insertion into soft tissue: A survey
Abolhassani, N., Patel, R., & Moallem, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.07.003 · Cited by 704
PVA hydrogel properties for biomedical application
Jiang, S., Liu, S., & Feng, W. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2011.04.005 · Cited by 554
Self-citationNeedle insertion modeling and simulation
DiMaio, S. P., & Salcudean, S. E. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817044 · Cited by 518 · cited 1×
“The needle force distribution indicates that axial forces between the needle and the tissue phantom are relatively uniform along the needle shaft (DiMaio and Salcudean 2003), so it is reasonable to assume a linear lateral force response for small displacement.”
BackgroundMechanics of Flexible Needles Robotically Steered through Soft Tissue
Misra, S., Reed, K. B., Schafer, B. W., Ramesh, K. T., & Okamura, A. M. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910369714 · Cited by 314 · cited 1×
“The curative effect is highly dependent on the accuracy of penetration (Misra et al. 2010).”
BackgroundQuantifying the mechanical properties of human skin to optimise future microneedle device design
Groves, R., Coulman, S. A., Birchall, J. C., & Evans, S. L. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.596481 · Cited by 119 · cited 1×
“The research on needle geometries can assist to optimize needle design (Groves et al. 2012) by using suitable diameter, needle tip, and bevel angle (see Table 3).”
MethodReality-based needle insertion simulation for haptic feedback in prostate brachytherapy
Hing, J. T., Brooks, A. D., & Desai, J. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1641779 · Cited by 98 · cited 1×
“(13) Hing et al. (2006), found that the stable cutting force is more or less constant, in porcine liver ex vivo, with some fluctuations due to rupture, depending on the level of inhomogeneity of the tissue.”
BackgroundPrestress as an optimal biomechanical parameter for needle penetration
Butz, K. D., Griebel, A. J., Novak, T., Harris, K. E., Kornokovich, A., Chiappetta, M. F., & Neu, C. P. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.01.049 · Cited by 20
Skin viscoelasticity studied in vitro by microprobe-based techniques
Jee, T., & Komvopoulos, K. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.10.006 · Cited by 17 · cited 1×
“Results with skin present two peaks of force curve, which stand for the peak force of stratum corneum and dermis, respectively (Jee and Komvopoulos 2014).”
Background
Cited by
Shin, J., Lee, J. S., Lee, C., Park, H., Yang, K., Jin, Y., Ryu, J. H., Hong, K. S., Moon, S., Chung, H., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500006 · Cited by 432
Cancer biomarker sensing using packaged plasmonic optical fiber gratings: Towards in vivo diagnosis
Ribaut, C., Loyez, M., Larrieu, J.-C., Chevineau, S., Lambert, P., Remmelink, M., Wattiez, R., & Caucheteur, C. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.081 · Cited by 183
“Hydrogels made of Poly(vinyl alcohol) are known to substitute tissue due to their similar biomechanical characterization and morphological structure (Jiang et al., 2014).”
Background
Metadata
- Authors
- Jiang, S., Li, P., Yu, Y., Liu, J., & Yang, Z.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2014-10
- Volume
- 47
- Issue
- 13
- Pages
- 3344-3353
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2164660172
- Cited by
- 158
- References
- 10
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.