CoChat

Coronary Access After TAVR

Open access
Ochiai, Tomoki, Chakravarty, Tarun, Yoon, Sung-Han, Kaewkes, Danon, Flint, Nir, Patel, Vivek, Mahani, Sahar, Tiwana, Ripandeep, Sekhon, Navjot, Nakamura, Mamoo, Cheng, Wen, Makkar, Raj · 2020 · JACC: Cardiovascular Interventions
Cited by 161

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

OBJECTIVES The aim of this study was to assess the incidence of unfavorable coronary access after transcatheter aortic valve replacement (TAVR) using post-implantation computed tomography (CT). BACKGROUND Real-world data regarding coronary access after TAVR assessed using post-implantation CT are scarce. METHODS Post-TAVR CT of 66 patients treated with Evolut R or Evolut PRO valves and 345 patients treated with SAPIEN 3 valves were analyzed. The distance from inflow of the transcatheter heart valve (THV) to the coronary ostia and the overlap between THV commissures and the coronary ostia were assessed. Coronary access was defined as unfavorable if the coronary ostium was below the skirt or in front of the THV commissural posts above the skirt in each coronary artery. RESULTS CT-identified features of unfavorable coronary access were observed in 34.8% (n = 23) for the left coronary artery and 25.8% (n = 17) for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 15.7% (n = 54) for the left coronary artery and 8.1% (n = 28) for the right coronary artery in the SAPIEN 3 group. In the Evolut R/Evolut PRO group, 16 coronary engagements were performed after TAVR, while 64 coronary engagements were performed in the SAPIEN 3 group after TAVR. In an engagement-level analysis, the success rates of selective coronary engagement were significantly lower in patients with CT-identified features of unfavorable coronary access compared with those with favorable coronary access in both the Evolut R/Evolut PRO (0.0% vs. 77.8%; p = 0.003) and SAPIEN 3 (33.3% vs. 91.4%; p = 0.003) groups. CONCLUSIONS Coronary access may be challenging in a significant proportion of patients after TAVR. THVs with low skirt or commissure height and large open cells that are designed to achieve commissure-to-commissure alignment with the native aortic valve may facilitate future coronary access. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcin.2020.01.216

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 161

Metadata

Authors
Ochiai, T., Chakravarty, T., Yoon, S.-H., Kaewkes, D., Flint, N., Patel, V., Mahani, S., Tiwana, R., Sekhon, N., Nakamura, M., Cheng, W., & Makkar, R.
Venue
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Published
2020-03
Volume
13
Issue
6
Pages
693-705
ISSN
  • 1876-7605 (ISSN-L)
  • 1936-8798
OpenAlex
W3011387687
Cited by
161
References
19
FWCI
15.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coronary Access After TAVR. https://app.cochat.ai/papers/10.1016/j.jcin.2020.01.216
The paper
Ochiai, T., Chakravarty, T., Yoon, S.-H., Kaewkes, D., Flint, N., Patel, V., Mahani, S., Tiwana, R., Sekhon, N., Nakamura, M., Cheng, W., & Makkar, R. (2020). Coronary Access After TAVR. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2020.01.216

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.