The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Facile synthesis of paper based graphene electrodes for point of care devices: A double stranded DNA (dsDNA) biosensor
Abstract
The demand for high-quality graphene for electronic applications is increasing due to its high carrier mobility and electrical conductivity. In this connection, printing technology is a reliable method towards the fabrication of conductive, disposable graphene-based electrode for low-cost sensor application. Herein, we aimed to report the synthesis of high-quality graphene nanosheets obtained by electrochemical exfoliation of biomass-derived from corn cob. The conductive ink was prepared from this exfoliated graphene and was utilized for the preparation of paper-based graphene electrode towards double stranded DNA (dsDNA) sensor application. This paper, based graphene electrode opens the possibility of direct electrochemical analysis of analyte without any sample preparation. In this study, two irreversible oxide peaks were obtained from paper-based printed graphene electrode, corresponds to oxidation of guanine (G) and adenine (A) of dsDNA in the linear range of 0.2 pg mL-1 to 5 pg mL-1 with the detection limit of 0.68 pg mL-1 and the sensitivity of 0.00656 mA pg-1 cm-2. Further, a small-scale printable circuit is fabricated using this graphene shows good conductivity of 1.145x103(S/m).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphene: Status and Prospects
Geim, A. K. (2009) · Science · doi:10.1126/science.1158877 · Cited by 13,942
Graphene-based composite materials
Stankovich, S., Dikin, D. A., Dommett, G. H. B., Kohlhaas, K. M., Zimney, E. J., Stach, E. A., Piner, R. D., Nguyen, S. T., & Ruoff, R. S. (2006) · Nature · doi:10.1038/nature04969 · Cited by 12,922
Thermal properties of graphene and nanostructured carbon materials
Balandin, A. A. (2011) · Nature Materials · doi:10.1038/nmat3064 · Cited by 6,244
Biased Bilayer Graphene: Semiconductor with a Gap Tunable by the Electric Field Effect
Castro, E. V., Novoselov, K. S., Morozov, S. V., Peres, N. M. R., dos Santos, J. M. B. L., Nilsson, J., Guinea, F., Geim, A. K., & Neto, A. H. C. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.216802 · Cited by 2,033
Cited by
Recent advances in isolation and detection of exosomal microRNAs related to Alzheimer's disease
Pishbin, E., Sadri, F., Dehghan, A., Kiani, M. J., Hashemi, N., Zare, I., Mousavi, P., & Rahi, A. (2023) · Environmental Research · doi:10.1016/j.envres.2023.115705 · Cited by 25
Metadata
- Authors
- Mohanraj, J., Durgalakshmi, D., Rakkesh, R. A., Balakumar, S., Rajendran, S., & Karimi-Maleh, H.
- Venue
- Journal of Colloid and Interface Science
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 566
- Pages
- 463-472
- ISSN
- 0021-9797 (ISSN-L)
- OpenAlex
- W3002353196
- Cited by
- 282
- References
- 4
- FWCI
- 19.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.