A systematic review finds that diagnostic reviews fail to incorporate quality despite available tools
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND OBJECTIVE To review existing quality assessment tools for diagnostic accuracy studies and to examine to what extent quality was assessed and incorporated in diagnostic systematic reviews. METHODS Electronic databases were searched for tools to assess the quality of studies of diagnostic accuracy or guides for conducting, reporting or interpreting such studies. The Database of Abstracts of Reviews of Effects (DARE; 1995-2001) was used to identify systematic reviews of diagnostic studies to examine the practice of quality assessment of primary studies. RESULTS Ninety-one quality assessment tools were identified. Only two provided details of tool development, and only a small proportion provided any indication of the aspects of quality they aimed to assess. None of the tools had been systematically evaluated. We identified 114 systematic reviews, of which 58 (51%) had performed an explicit quality assessment and were further examined. The majority of reviews used more than one method of incorporating quality. CONCLUSION Most tools to assess the quality of diagnostic accuracy studies do not start from a well-defined definition of quality. None has been systematically evaluated. The majority of existing systematic reviews fail to take differences in quality into account. Reviewers should consider quality as a possible source of heterogeneity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Self-citationTowards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Self-citationEmpirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 1×
“Evidence is accumulating on the amount and direction of these potential threats to validity [5,6].”
BackgroundThe STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Self-citationMcGee, S. (1999) · JAMA · doi:10.1001/jama.281.11.1022 · Cited by 583
Research works printed but not linked: 100
- Jaeschke, 1994, Users' guides to the medical literature. III. How to use an article about a diagnostic test. A. Are the results of the study valid?, JAMA, 271, 389, 10.1001/jama.271.5.389 · doi:10.1001/jama.271.5.389 · Paper page
- Jaeschke, 1994, Users' guides to the medical literature. III. How to use an article about a diagnostic test. B. What are the results and will they help me in caring for my patients?, JAMA, 271, 703, 10.1001/jama.271.9.703 · doi:10.1001/jama.271.9.703 · Paper page
- Irwig, 1994, Guidelines for meta-analyses evaluating diagnostic tests, Ann Intern Med, 120, 667, 10.7326/0003-4819-120-8-199404150-00008 · DOI · Paper page
- Whiting, 2004, Sources of variation and bias in studies of diagnostic accuracy: a systematic review, Ann Intern Med, 140, 189, 10.7326/0003-4819-140-3-200402030-00010 · DOI · Paper page
- Whiting, 2004, Development and validation of methods for assessing the quality of diagnostic accuracy studies, Health Technol Assess, 8, 1, 10.3310/hta8250 · DOI · Paper page
- Reid, 1995, Use of methodological standards in diagnostic test research: getting better but still not good, JAMA, 274, 645, 10.1001/jama.274.8.645 · doi:10.1001/jama.274.8.645 · Paper page
- Sheps, 1984, The assessment of diagnostic tests: a survey of current medical research, JAMA, 252, 2418, 10.1001/jama.252.17.2418 · doi:10.1001/jama.252.17.2418 · Paper page
- Cooper, 1988, The poor quality of early evaluations of magnetic resonance imaging, JAMA, 259, 3277, 10.1001/jama.259.22.3277 · doi:10.1001/jama.259.22.3277
- Beam, 1991, Status of clinical MR evaluations 1985–1988: baseline and design for further assessments, Radiology, 180, 265, 10.1148/radiology.180.1.2052708 · doi:10.1148/radiology.180.1.2052708
- Kent, 1992, Disease, level of impact, and quality of research methods: three dimensions of clinical efficacy assessment applied to magnetic resonance imaging, Invest Radiol, 27, 245, 10.1097/00004424-199203000-00014 · DOI · Paper page
- Chien, 1997, The diagnostic accuracy of cervico-vaginal fetal fibronectin in predicting preterm delivery: an overview, Br J Obstet Gynaecol, 104, 436, 10.1111/j.1471-0528.1997.tb11495.x · DOI · Paper page
- de Vries, 1996, Summary receiver operating characteristic curves as a technique for meta-analysis of the diagnostic performance of duplex ultrasonography in peripheral arterial disease, Acad Radiol, 3, 361, 10.1016/S1076-6332(96)80257-1 · DOI
- Fahey, 1995, Meta-analysis of Pap test accuracy, Am J Epidemiol, 141, 680, 10.1093/oxfordjournals.aje.a117485 · DOI · Paper page
- Heffner, 1995, Pleural fluid chemical analysis in parapneumonic effusions: a meta-analysis, Am J Respir Crit Care Med, 151, 1700, 10.1164/ajrccm.151.6.7767510 · doi:10.1164/ajrccm.151.6.7767510
- Heffner, 1998, Methodologic standards for diagnostic test research in pulmonary medicine, Chest, 114, 877, 10.1378/chest.114.3.877 · DOI
- Hobbs, 1997, A review of near patient testing in primary care, Health Technol Assess, 1, 1, 10.3310/hta1050 · DOI
- Lensing, 1993, 125I-fibrinogen leg scanning: reassessment of its role for the diagnosis of venous thrombosis in post-operative patients, Thromb Haemost, 69, 2, 10.1055/s-0038-1651177 · DOI
- Radack, 1993, Is there a valid association between skin tags and colonic polyps: insights from a quantitative and methodologic analysis of the literature, J Gen Intern Med, 8, 413, 10.1007/BF02599617 · DOI
- Devous, 1998, SPECT brain imaging in epilepsy: a meta-analysis, J Nucl Med, 39, 285
- Mol, 1997, The accuracy of serum chlamydial antibodies in the diagnosis of tubal pathology: a meta-analysis, Fertil Steril, 67, 1031, 10.1016/S0015-0282(97)81435-5 · DOI · Paper page
- Owens, 1996, Polymerase chain reaction for the diagnosis of HIV infection in adults: a meta-analysis with recommendations for clinical practice and study design, Ann Intern Med, 124, 803, 10.7326/0003-4819-124-9-199605010-00004 · DOI
- Rao, 1995, The role of antineutrophil cytoplasmic antibody (c-ANCA) testing in the diagnosis of Wegener granulomatosis: a literature review and meta-analysis, Ann Intern Med, 123, 925, 10.7326/0003-4819-123-12-199512150-00005 · DOI · Paper page
- Reed, 1996, Sputum Gram's stain in community-acquired pneumococcal pneumonia: a meta-analysis, West J Med, 165, 197
- Swart, 1995, The accuracy of hysterosalpingography in the diagnosis of tubal pathology: a meta-analysis, Fertil Steril, 64, 486, 10.1016/S0015-0282(16)57781-4 · doi:10.1016/s0015-0282(16)57781-4
- Wells, 1995, Accuracy of ultrasound for the diagnosis of deep venous thrombosis in asymptomatic patients after orthopedic surgery: a meta-analysis, Ann Intern Med, 122, 47, 10.7326/0003-4819-122-1-199501010-00008 · DOI · Paper page
- Attia, 1999, Diagnosis of thyroid disease in hospitalized patients: a systematic review, Arch Intern Med, 159, 658, 10.1001/archinte.159.7.658 · DOI
- Badgett, 1996, How well can the chest radiograph diagnose left ventricular dysfunction?, J Gen Intern Med, 11, 625, 10.1007/BF02599031 · DOI
- Becker, 1996, D-dimer testing and acute venous thromboembolism, Arch Intern Med, 156, 939, 10.1001/archinte.156.9.939 · doi:10.1001/archinte.156.9.939 · Paper page
- Bradley, 1998, Alcohol screening questionnaires in women: a critical review, JAMA, 280, 166, 10.1001/jama.280.2.166 · DOI · Paper page
- Buntinx, 1997, The diagnostic value of macroscopic haematuria in diagnosing urological cancers: a meta-analysis, Fam Pract, 14, 63, 10.1093/fampra/14.1.63 · doi:10.1093/fampra/14.1.63
- Conde-Agudelo, 1998, Triple-marker test as screening for Down syndrome: a meta-analysis, Obstet Gynecol Surv, 53, 369, 10.1097/00006254-199806000-00022 · DOI
- Da Silva, 1995, Accuracy of leukocyte indices and C-reactive protein for diagnosis of neonatal sepsis: a critical review, Pediatr Infect Dis J, 14, 362, 10.1097/00006454-199505000-00005 · DOI · Paper page
- De Bernardinis, 1999, Discriminant power and information content of Ranson's prognostic signs in acute pancreatitis: a meta-analytic study, Crit Care Med, 27, 2272, 10.1097/00003246-199910000-00035 · DOI
- Hallan, 1997, The accuracy of C-reactive protein in diagnosing acute appendicitis, Scand J Clin Lab Invest, 57, 373, 10.3109/00365519709084584 · DOI
- Heffner, 1997, Diagnostic value of tests that discriminate between exudative and transudative pleural effusions, Chest, 111, 970, 10.1378/chest.111.4.970 · doi:10.1378/chest.111.4.970
- Kearon, 1998, Noninvasive diagnosis of deep venous thrombosis, Ann Intern Med, 128, 663, 10.7326/0003-4819-128-8-199804150-00011 · DOI · Paper page
- Koelemay, 1996, Diagnosis of arterial disease of the lower extremities with duplex ultrasonography, Br J Surg, 83, 404, 10.1002/bjs.1800830336 · DOI · Paper page
- Koumans, 1998, Laboratory testing for Neisseria gonorrhoeae by recently introduced nonculture tests: a performance review with clinical and public health considerations, Clin Infect Dis, 27, 1171, 10.1086/514994 · DOI
- Lacasse, 1999, Transthoracic needle aspiration biopsy for the diagnosis of localised pulmonary lesions: a meta-analysis, Thorax, 54, 884, 10.1136/thx.54.10.884 · DOI
- Littenberg, 1995, Clinical efficacy of SPECT bone imaging for low back pain, J Nucl Med, 36, 1707
- Metlay, 1997, Does this patient have community-acquired pneumonia? Diagnosing pneumonia by history and physical examination, JAMA, 278, 1440, 10.1001/jama.278.17.1440 · doi:10.1001/jama.278.17.1440 · Paper page
- Mol, 1998, The performance of CA-125 measurement in the detection of endometriosis: a meta-analysis, Fertil Steril, 70, 1101, 10.1016/S0015-0282(98)00355-0 · DOI · Paper page
- Mol, 1998, The accuracy of single serum progesterone measurement in the diagnosis of ectopic pregnancy: a meta-analysis, Hum Reprod, 13, 3220, 10.1093/humrep/13.11.3220 · DOI · Paper page
- Nuovo, 1997, Is cervicography a useful diagnostic test? a systematic overview of the literature, J Am Board Fam Pract, 10, 390
- Pollitt, 1997, Neonatal screening for inborn errors of metabolism: cost, yield and outcome, Health Technol Assess, 1, 1, 10.3310/hta1070 · DOI · Paper page
- Rappeport, 1996, MR imaging before arthroscopy in knee joint disorders?, Acta Radiol, 37, 602, 10.3109/02841859609177683 · doi:10.3109/02841859609177683
- van den Hoogen, 1995, On the accuracy of history, physical examination, and erythrocyte sedimentation rate in diagnosing low back pain in general practice, Spine, 20, 318, 10.1097/00007632-199502000-00010 · DOI · Paper page
- van Tulder, 1997, Spinal radiographic findings and nonspecific low back pain: a systematic review of observational studies, Spine, 22, 427, 10.1097/00007632-199702150-00015 · DOI · Paper page
- Panzer, 1986, A methodologic assessment of studies comparing magnetic resonance imaging and computed tomography of the brain, Acta Radiol Suppl, 369, 269
- Hrung, 1999, Accuracy of MR imagining in the work-up of suspicious breast lesions: a diagnostic meta-analysis, Acad Radiol, 6, 387, 10.1016/S1076-6332(99)80189-5 · doi:10.1016/s1076-6332(99)80189-5
- Rothwell, 2000, Critical appraisal of the design and reporting of studies of imaging and measurement of carotid stenosis, Stroke, 31, 1444, 10.1161/01.STR.31.6.1444 · DOI
- van der Wurff, 2000, Clinical tests of the sacroiliac joint: a systematic methodological review. Part 1: Reliability, Man Ther, 5, 30, 10.1016/S1356-689X(99)90228-X · doi:10.1016/s1356-689x(99)90228-x
- Windeler, 1988, Description and evaluation of diagnostic-tests in German-language medical journals, Schweiz Med Wochenschr, 118, 1437
- Mullins, 2000, The role of spiral volumetric computed tomography in the diagnosis of pulmonary embolism, Arch Intern Med, 160, 293, 10.1001/archinte.160.3.293 · doi:10.1001/archinte.160.3.293
- Fiellin, 2000, Screening for alcohol problems in primary care, Arch Intern Med, 160, 1977, 10.1001/archinte.160.13.1977 · DOI · Paper page
- Berry, 2002, The cost-effectiveness of magnetic resonance angiography for carotid artery stenosis and peripheral vascular disease: a systematic review, Health Technol Assess, 6, 1, 10.3310/hta6070 · DOI · Paper page
- Becker, 1989, Real-time ultrasonography for the diagnosis of lower extremity deep venous thrombosis: the wave of the future?, Arch Intern Med, 149, 1731, 10.1001/archinte.149.8.1731 · doi:10.1001/archinte.149.8.1731
- Guyatt, 1992, Laboratory diagnosis of iron-deficiency anemia: an overview, J Gen Intern Med, 7, 145, 10.1007/BF02598003 · DOI · Paper page
- Hoffman, 1991, Diagnostic accuracy and clinical utility of thermography for lumbar radiculopathy: a meta-analysis, Spine, 16, 623, 10.1097/00007632-199106000-00005 · doi:10.1097/00007632-199106000-00005
- Holleman, 1995, Does the clinical examination predict airflow limitations?, JAMA, 273, 313, 10.1001/jama.273.4.313 · doi:10.1001/jama.273.4.313
- Kent, 1992, Diagnosis of lumbar spinal stenosis in adults: a metaanalysis of the accuracy of CT, MR, and myelography, AJR Am J Roentgenol, 158, 1135, 10.2214/ajr.158.5.1533084 · DOI · Paper page
- Philbrick, 1980, Methodologic problems of exercise testing for coronary artery disease: groups, analysis and bias, Am J Cardiol, 46, 807, 10.1016/0002-9149(80)90432-4 · DOI · Paper page
- Arrive, 2000, A scale of methodological quality for clinical studies of radiologic examinations, Radiology, 217, 69, 10.1148/radiology.217.1.r00oc0669 · DOI · Paper page
- Khan, 2001, Systematic reviews to evaluate diagnostic tests, Eur J Obstet Gynecol Reprod Biol, 95, 6, 10.1016/S0301-2115(00)00463-2 · DOI
- Mulrow, 1989, Assessing quality of a diagnostic test evaluation, J Gen Intern Med, 4, 288, 10.1007/BF02597398 · DOI
- Black, 1990, How to evaluate the radiology literature, AJR Am J Roentgenol, 154, 17, 10.2214/ajr.154.1.2104704 · doi:10.2214/ajr.154.1.2104704
- Jensen, 1999, Methodik diagnostischer Validierungsstudien: Fehler in der Studienplanung und Auswertung, Med Klin, 94, 522, 10.1007/BF03044946 · DOI
- Greiner, 2000, Epidemiologic issues in the validation of veterinary diagnostic tests, Prev Vet Med, 45, 3, 10.1016/S0167-5877(00)00114-8 · DOI · Paper page
- Kobberling, 1990, Memorandum for the evaluation of diagnostic measures, J Clin Chem Clin Biochem, 28, 873
- Greenhalgh, 1997, How to read a paper: papers that report diagnostic or screening tests, BMJ, 315, 540, 10.1136/bmj.315.7107.540 · DOI · Paper page
- Heffner, 1998, Evaluating diagnostic tests in the pleural space: differentiating transudates from exudates as a model, Clin Chest Med, 19, 277, 10.1016/S0272-5231(05)70077-0 · DOI
- 1981, How to read clinical journals: II. To learn about a diagnostic test, Can Med Assoc J, 124, 703
- Deeks, 1999, Using evaluations of diagnostic tests: understanding their limitations and making the most of available evidence, Ann Oncol, 10, 761, 10.1023/A:1008359805260 · DOI
- Freedman, 1987, Evaluating and comparing imaging techniques: a review and classification of study designs, Br J Radiol, 60, 1071, 10.1259/0007-1285-60-719-1071 · DOI
- Gifford, 1999, Evaluating dementia screening tests: methodologic standards to rate their performance, Neurology, 52, 224, 10.1212/WNL.52.2.224 · DOI · Paper page
- Thornbury, 1991, Increasing the scientific quality of clinical efficacy studies of magnetic resonance imaging, Invest Radiol, 26, 829, 10.1097/00004424-199109000-00011 · doi:10.1097/00004424-199109000-00011
- Deyo, 1994, Designing studies of diagnostic tests for low back pain or radiculopathy, Spine, 19, S2057, 10.1097/00007632-199409151-00007 · doi:10.1097/00007632-199409151-00007
- Bruns, 2000, Toward a checklist for reporting of studies of diagnostic accuracy of medical tests, Clin Chem, 46, 893, 10.1093/clinchem/46.7.893 · DOI · Paper page
- Haynes, 1995, Purpose and procedure (abbreviated), Evid Based Med, 1, 2
- Mower, 1999, Evaluating bias and variability in diagnostic test reports, Ann Emerg Med, 33, 85, 10.1016/S0196-0644(99)70422-1 · DOI
- Deeks, 2001, Systematic reviews in health care: Systematic reviews of evaluations of diagnostic and screening tests, BMJ, 323, 157, 10.1136/bmj.323.7305.157 · DOI · Paper page
- Badgett, 1997, Can the clinical examination diagnose left-sided heart failure in adults?, JAMA, 277, 1712, 10.1001/jama.277.21.1712 · DOI
- Bastian, 1997, Is this patient pregnant? Can you reliably rule in or rule out early pregnancy by clinical examination?, JAMA, 278, 586, 10.1001/jama.278.7.586 · DOI
- Selker, 1997, An evaluation of technologies for identifying acute cardiac ischemia in the emergency department: a report from a National Heart Attack Alert Program working group, Emerg Med, 29, 13
- Anand, 1998, Does this patient have deep vein thrombosis?, JAMA, 279, 1094, 10.1001/jama.279.14.1094 · DOI
- Tugwell, 1997, Laboratory evaluation in the diagnosis of Lyme disease: clinical guideline, part 2, Ann Intern Med, 127, 1109, 10.7326/0003-4819-127-12-199712150-00011 · DOI · Paper page
- Bachmann, 1998, Impact of diabetic retinopathy screening on a British district population: case detection and blindness prevention in an evidence-based model, J Epidemiol Community Health, 52, 45, 10.1136/jech.52.1.45 · DOI · Paper page
- Spencer-Green, 1997, Test performance in systemic sclerosis: anti-centromere and Anti-Scl-70 antibodies, Am J Med, 103, 242, 10.1016/S0002-9343(97)00023-5 · DOI
- Whited, 1998, Does this patient have a mole or a melanoma?, JAMA, 279, 696, 10.1001/jama.279.9.696 · DOI
- Bell, 1998, Screening for ovarian cancer: a systematic review, Health Technol Assess, 2, 1, 10.3310/hta2020 · doi:10.3310/hta2020
- Bonis, 1997, Correlation of biochemical response to interferon alfa with histological improvement in hepatitis C: a meta-analysis of diagnostic test characteristics, Hepatology, 26, 1035, 10.1002/hep.510260436 · DOI
- Mayer, 1997, Systematic review of the diagnostic accuracy of dermatoscopy in detecting malignant melanoma, Med J Aust, 167, 206, 10.5694/j.1326-5377.1997.tb138847.x · DOI · Paper page
- Huicho, 1996, Fecal screening tests in the approach to acute infectious diarrhea: a scientific overview, Pediatr Infect Dis J, 15, 486, 10.1097/00006454-199606000-00004 · DOI · Paper page
- Pearl, 1996, Ultrasonography for the initial evaluation of blunt abdominal trauma: a review of prospective trials, Ann Emerg Med, 27, 353, 10.1016/S0196-0644(96)70273-1 · DOI
- Bastian, 1998, Diagnostic efficiency of home pregnancy test kits: a meta-analysis, Arch Fam Med, 7, 465, 10.1001/archfami.7.5.465 · DOI
- Owens, 1996, A meta-analytic evaluation of the polymerase chain reaction for the diagnosis of HIV infection in infants, JAMA, 275, 1342, 10.1001/jama.275.17.1342 · doi:10.1001/jama.275.17.1342
- Liedberg, 1996, Evidence-based evaluation of three imaging methods for the temporomandibular disc, Dentomaxillofac Radiol, 25, 234, 10.1259/dmfr.25.5.9161176 · DOI
- Loy, 1996, Do commercial serological kits for Helicobacter pylori infection differ in accuracy? A meta-analysis, Am J Gastroenterol, 91, 1138
- Whiting, 2003, The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews, BMC Med Res Methodol, 3, 25, 10.1186/1471-2288-3-25 · DOI · Paper page
- de Vet, 2001, Systematic reviews of diagnostic research: considerations about assessment and incorporation of methodological quality, Eur J Epidemiol, 17, 301, 10.1023/A:1012751326462 · DOI
Cited by
Systematic reviews: CRD's guidance for undertaking reviews in health care
Tacconelli, E. (2010) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(10)70065-7 · Cited by 3,245
Epidemiology and reporting characteristics of systematic reviews.
Moher, D., Tetzlaff, J., Tricco, A. C., Sampson, M., & Altman, D. G. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040078 · Cited by 891
“Typically the focus of such examinations is in specific health care areas [8–11] or type of SR [12,13].”
BackgroundEvidence of bias and variation in diagnostic accuracy studies
Rutjes, A. W. S., Reitsma, J. B., Di Nisio, M., Smidt, N., van Rijn, J. C., & Bossuyt, P. M. M. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.050090 · Cited by 611
Self-citationAssessing the Risk of Bias of Individual Studies in Systematic Reviews of Health Care Interventions
Viswanathan, M., Patnode, C. D., Berkman, N. D., Bass, E. B., Chang, S., Hartling, L., Murad, M. H., Treadwell, J. R., & Kane, R. L. (2017) · doi:10.23970/ahrqepcmethguide2 · Cited by 448
de Bondt, R. B. J., Nelemans, P. J., Hofman, P. A. M., Casselman, J. W., Kremer, B., van Engelshoven, J. M. A., & Beets-Tan, R. G. H. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.02.037 · Cited by 376
Metadata
- Authors
- Whiting, P., Rutjes, A. W. S., Dinnes, J., Reitsma, J. B., Bossuyt, P. M. M., & Kleijnen, J.
- Venue
- Journal of Clinical Epidemiology
- Publisher
- Elsevier BV
- Published
- 2005-01
- Volume
- 58
- Issue
- 1
- Pages
- 1-12
- ISSN
- 0895-4356 (ISSN-L)
- OpenAlex
- W2030551462
- Cited by
- 79
- References
- 5
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A systematic review finds that diagnostic reviews fail to incorporate quality despite available tools. https://app.cochat.ai/papers/10.1016/j.jclinepi.2004.04.008
- The paper
- Whiting, P., Rutjes, A. W. S., Dinnes, J., Reitsma, J. B., Bossuyt, P. M. M., & Kleijnen, J. (2005). A systematic review finds that diagnostic reviews fail to incorporate quality despite available tools. Journal of Clinical Epidemiology. https://doi.org/10.1016/j.jclinepi.2004.04.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.