The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis
Open accessAbstract
OBJECTIVES The purpose of this systematic review was to explore the diagnostic accuracy of various cardiovascular magnetic resonance (CMR) index tests for the diagnosis of acute myocarditis in adult patients. BACKGROUND Acute myocarditis remains one of the most challenging diagnoses in cardiology. CMR has emerged as the diagnostic tool of choice to detect acute myocardial injury and necrosis in patients with suspected myocarditis. METHODS We considered all diagnostic cohort and case-control studies. We searched MEDLINE, EMBASE, Cochrane Library, SCOPUS, and Web of Science up to April 21, 2017. We used the Quality Assessment of Diagnostic Accuracy Studies-2 tool to assess the quality of included studies. PROSPERO registration number CRD42017055778 was used. RESULTS Twenty-two studies were included in the systematic review. Because significant heterogeneity exists among the studies, we only present hierarchical receiver operator curves. The areas under the curve (AUC) for each index test were for T1 mapping 0.95 (95% confidence interval [CI]: 0.93 to 0.97), for T2 mapping 0.88 (95% CI: 0.85 to 0.91), for extracellular volume fraction (ECV) 0.81 (95% CI: 0.78 to 0.85), for increased T2 ratio/signal 0.80 (95% CI: 0.76 to 0.83), for late gadolinium enhancement (LGE) 0.87 (95% CI: 0.84 to 0.90), for early gadolinium enhancement (EGE) 0.78 (95% CI: 0.74 to 0.81), and for the Lake Louise criteria (LLC) 0.81 (95% CI: 0.77 to 0.84). Native T1 mapping had superior diagnostic accuracy across all index tests. The AUC of T2 mapping was greater than the AUC of increased T2 ratio/signal and EGE, whereas ECV showed no superiority compared with other index tests. LGE had better diagnostic accuracy compared with the classic CMR index tests, similar accuracy with T2 mapping and ECV, and only T1 mapping surpassed it. CONCLUSIONS Novel CMR mapping techniques provide high diagnostic accuracies for the diagnosis of acute myocarditis and constitute promising successors of the classic elements of the LLC for routine diagnostic protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Cooper, L. T., Baughman, K. L., Feldman, A. M., Frustaci, A., Jessup, M., Kuhl, U., Levine, G. N., Narula, J., Starling, R. C., Towbin, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.186093 · Cited by 1,030 · cited 2×
“Therefore, it is only recommended in a limited number of clinical scenarios such as patients with evidence of heart failure in combination with acute disease ( 2 weeks, Class I) or left ventricular dilation ( 3 months, Class I) or specific other cases of heart failure (Class IIa) (4).”
BackgroundKindermann, I., Barth, C., Mahfoud, F., Ukena, C., Lenski, M., Yilmaz, A., Klingel, K., Kandolf, R., Sechtem, U., Cooper, L. T., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.074 · Cited by 919 · cited 1×
“Although endomyocardial biopsy is considered the gold standard for the diagnosis of acute myocarditis (3), several limitations restrict its”
Backgroundmetandi: Meta-analysis of diagnostic accuracy using hierarchical logistic regression
Harbord, R. M., & Whiting, P. (2009) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0900900203 · Cited by 453
Cited by
Cardiovascular Magnetic Resonance in Nonischemic Myocardial Inflammation
Ferreira, V. M., Schulz-Menger, J., Holmvang, G., Kramer, C. M., Carbone, I., Sechtem, U., Kindermann, I., Gutberlet, M., Cooper, L. T., Liu, P., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.072 · Cited by 2,059
Law, Y. M., Lal, A. K., Chen, S., Čiháková, D., Cooper, L. T., Deshpande, S., Godown, J., Grosse-Wortmann, L., Robinson, J. D., Towbin, J. A., et al. (2021) · Circulation · doi:10.1161/cir.0000000000001001 · Cited by 340
Prognostic Value of Repeating Cardiac Magnetic Resonance in Patients With Acute Myocarditis
Aquaro, G. D., Ghebru Habtemicael, Y., Camastra, G., Monti, L., Dellegrottaglie, S., Moro, C., Lanzillo, C., Scatteia, A., Di Roma, M., Pontone, G., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.08.1061 · Cited by 253
A Novel Circulating Noncoding Small RNA for the Detection of Acute Myocarditis
Blanco-Domínguez, R., Sánchez-Díaz, R., de la Fuente, H., Jiménez-Borreguero, L. J., Matesanz-Marín, A., Relaño, M., Jiménez-Alejandre, R., Linillos-Pradillo, B., Tsilingiri, K., Martín-Mariscal, M. L., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2003608 · Cited by 196
Metadata
- Authors
- Kotanidis, C. P., Bazmpani, M.-A., Haidich, A.-B., Karvounis, C., Antoniades, C., & Karamitsos, T. D.
- Venue
- JACC: Cardiovascular Imaging
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 11
- Issue
- 11
- Pages
- 1583-1590
- ISSN
- 1876-7591 (ISSN-L)
- 1936-878X
- OpenAlex
- W2791721098
- Cited by
- 178
- References
- 5
- FWCI
- 14.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis. https://app.cochat.ai/papers/10.1016/j.jcmg.2017.12.008
- The paper
- Kotanidis, C. P., Bazmpani, M.-A., Haidich, A.-B., Karvounis, C., Antoniades, C., & Karamitsos, T. D. (2018). Diagnostic Accuracy of Cardiovascular Magnetic Resonance in Acute Myocarditis. JACC: Cardiovascular Imaging. https://doi.org/10.1016/j.jcmg.2017.12.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.