Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Hydrogel-forming microneedles enhance transdermal delivery of metformin hydrochloride

Open access
Migdadi, Eman M., Courtenay, Aaron J., Tekko, Ismaiel A., McCrudden, Maelíosa T.C., Kearney, Mary-Carmel, McAlister, Emma, McCarthy, Helen O., Donnelly, Ryan F.·2018·Journal of Controlled Release

Abstract

We investigated, for the first time, the potential for a hydrogel-forming microneedle (MN) patch to deliver the high-dose drug metformin HCl transdermally in a sustained manner. This may minimize some gastrointestinal side effects and small intestine absorption variations associated with oral delivery. Patches (two layers) were assembled from a lyophilised drug reservoir layer, with the MN layer made from aqueous blend of 20% w/w poly (methylvinylether- co -maleic acid) crosslinked by esterification with 7.5% w/w poly (ethylene glycol) 10,000 Da. >90% of metformin was recovered from homogeneous drug reservoirs. Drug reservoir dissolution time in PBS (pH 7.4) was <10 min. MN penetrated a validated skin model Parafilm® M consistently. Permeation of metformin HCl across dermatomed neonatal porcine skin in vitro was enhanced by using MN. The combined MN and metformin HCl reservoir patch (containing 75 mg or 50 mg metformin HCl, respectively) delivered 9.71 ± 2.22 mg and 10.04 ± 1.92 mg at 6 h, respectively, and 28.15 ± 2.37 mg and 23.25 ± 3.58 mg at 24 h, respectively.In comparison, 0.34 ± 0.39 mg and 0.85 ± 0.68 mg was delivered at 6 h, respectively, and 0.39 ± 0.39 mg and 1.01 ± 0.84 mg was delivered at 24 h, respectively, from a control set-up employing only the drug reservoirs. In vivo , metformin HCl was detected in rat plasma at 1 h post MN application at a concentration of 0.62 ± 0.51 μg/mL, increasing to 3.76 ± 2.58 μg/ml at 3 h. A maximal concentration of 3.77 ± 2.09 μg/ml was achieved at 24 h. C ss was 3.2 μg/mL. Metformin transdermal bioavailability using MNs was estimated as 30%.Hydrogel-forming MN are a promising technology that has demonstrated successful transdermal delivery of metformin HCl. Potential clearly exists for administration of other high-dose drugs using this system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jconrel.2018.07.009

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 279

Metadata

Authors
Migdadi, E. M., Courtenay, A. J., Tekko, I. A., McCrudden, M. T. C., Kearney, M.-C., McAlister, E., McCarthy, H. O., & Donnelly, R. F.
Venue
Journal of Controlled Release
Publisher
Elsevier BV
Published
2018-09
Volume
285
Pages
142-151
ISSN
0168-3659 (ISSN-L)
OpenAlex
W2855666604
Cited by
279
References
27
FWCI
9.95
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hydrogel-forming microneedles enhance transdermal delivery of metformin hydrochloride. https://app.cochat.ai/papers/10.1016/j.jconrel.2018.07.009
The paper
Migdadi, E. M., Courtenay, A. J., Tekko, I. A., McCrudden, M. T. C., Kearney, M.-C., McAlister, E., McCarthy, H. O., & Donnelly, R. F. (2018). Hydrogel-forming microneedles enhance transdermal delivery of metformin hydrochloride. Journal of Controlled Release. https://doi.org/10.1016/j.jconrel.2018.07.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.