Evaluation of medication-related clinical decision support alert overrides in the intensive care unit
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Purpose: Medication‐related clinical decision support (CDS) has been identified as a method to improve patient outcomes but is historically frequently overridden and may be inappropriately so. Patients in the intensive care unit (ICU) are at a higher risk of harm from adverse drug events (ADEs) and these overrides may increase patient harm. The objective of this study is to determine appropriateness of overridden medication‐related CDS overrides in the ICU. Materials and methods: We evaluated overridden medication‐related alerts of four alert categories from January 2009 to December 2011. The primary outcome was the appropriateness of a random sample of overrides based on predetermined criteria. Secondary outcomes included the incidence of adverse drug events (ADEs) that resulted from the overridden alert. Results: A total of 47,449 overridden alerts were included for evaluation. The appropriateness rate for overridden alerts varied by alert category (allergy: 94%, drug‐drug interaction: 84%, geriatric: 57%, renal: 27%). A total of seven actual ADEs were identified in the random sample and where the medication(s) was administered (n = 366), with an increased risk of ADEs associated with inappropriately overridden alerts (p = 0.0078). Conclusions: The appropriateness of medication‐related clinical decision support overrides in the ICU varied substantially by the type of alert. Inappropriately overridden alerts were associated with an increased risk of ADEs compared to appropriately overridden alerts. HighlightsMedication‐related clinical decision support has been shown to improve patient safety, but is frequently overriddenThis study evaluated the appropriateness of overrides that exhibits an increased risk for adverse events.Alert categories evaluated were drug‐allergy, drug‐drug interaction, geriatric and renalOverall, weighted appropriateness of the evaluated overrides was 92.3%, with significant variance by alert type (p < 0.001)Inappropriately overridden alerts were associated with an increased risk of adverse drug events (p < 0.0078)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Benjamin, E. J. (1994) · JAMA · doi:10.1001/jama.1994.03510350050036 · Cited by 2,613
The American Geriatrics Society 2012 Beers Criteria Update Expert Panel (2012) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2012.03923.x · Cited by 2,578
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127
Self-citationBates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
Self-citationThe Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260
Self-citationPrimary and Secondary Prevention of Cardiovascular Disease
Vandvik, P. O., Lincoff, A. M., Gore, J. M., Gutterman, D. D., Sonnenberg, F. A., Alonso-Coello, P., Akl, E. A., Lansberg, M. G., Guyatt, G. H., & Spencer, F. A. (2012) · Chest · doi:10.1378/chest.11-2306 · Cited by 476
Improving Acceptance of Computerized Prescribing Alerts in Ambulatory Care
Shah, N. R., Seger, A. C., Seger, D. L., Fiskio, J. M., Kuperman, G. J., Blumenfeld, B., Recklet, E. G., Bates, D. W., & Gandhi, T. K. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1868 · Cited by 353
Self-citationKesselheim, A. S., Cresswell, K., Phansalkar, S., Bates, D. W., & Sheikh, A. (2011) · Health Affairs · doi:10.1377/hlthaff.2010.1111 · Cited by 277
Self-citationOverrides of medication-related clinical decision support alerts in outpatients
Nanji, K. C., Slight, S. P., Seger, D. L., Cho, I., Fiskio, J. M., Redden, L. M., Volk, L. A., & Bates, D. W. (2014) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2013-001813 · Cited by 219
Self-citationTurning Off Frequently Overridden Drug Alerts: Limited Opportunities for Doing It Safely
van der Sijs, H., Aarts, J., van Gelder, T., Berg, M., & Vulto, A. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2311 · Cited by 175
Lin, C.-P., Payne, T. H., Nichol, W. P., Hoey, P. J., Anderson, C. L., & Gennari, J. H. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2453 · Cited by 110
Slight, S. P., Seger, D. L., Nanji, K. C., Cho, I., Maniam, N., Dykes, P. C., & Bates, D. W. (2013) · PLoS ONE · doi:10.1371/journal.pone.0085071 · Cited by 86
Self-citationMiller, A. M., Boro, M. S., Korman, N. E., & Davoren, J. B. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000262 · Cited by 41
Cited by
Medication-related clinical decision support alert overrides in inpatients
Nanji, K. C., Seger, D. L., Slight, S. P., Amato, M. G., Beeler, P. E., Her, Q. L., Dalleur, O., Eguale, T., Wong, A., Silvers, E. R., et al. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocx115 · Cited by 179
Self-citationAppropriateness of Overridden Alerts in Computerized Physician Order Entry: Systematic Review
Poly, T. N., Islam, M. M., Yang, H.-C., & Li, Y.-C. (. (2020) · JMIR Medical Informatics · doi:10.2196/15653 · Cited by 118
“Interrater agreement, kappa (95% CI) Evaluation raterEvaluation criteriaAppropriateness (%)Overridden (%)Type of alerts Reference 0.87 (0.85-0.90)Clinical pharmacist and research assistant Based on previously published data including guidelines 88.893.0DoseWong et al [7] NRNRNRbInpatient: 83.9; outpatient: 100 Inpatie…”
BackgroundInfluentialWong, A., Amato, M. G., Seger, D. L., Rehr, C., Wright, A., Slight, S. P., Beeler, P. E., Orav, E. J., & Bates, D. W. (2018) · BMJ Quality & Safety · doi:10.1136/bmjqs-2017-007531 · Cited by 77
“8 This acceptance rate was also significantly greater than the rest of the studied alert types.”
ResultSelf-citationShah, S. N., Amato, M. G., Garlo, K. G., Seger, D. L., & Bates, D. W. (2021) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaa222 · Cited by 43
“It has been reported that one-third of patients receive inappropriate doses based on renal function.10 Medication-related CDS represents an effective way to reduce errors, and ADEs.17–19 However, this impact may be decreased or even extinguished if too many clinically inappropriate alerts are given.20–22 This problem…”
InfluentialSelf-citationComparison of Medication Alerts from Two Commercial Applications in the USA
Shah, S. N., Seger, D. L., Fiskio, J. M., Horn, J. R., & Bates, D. W. (2021) · Drug Safety · doi:10.1007/s40264-021-01048-0 · Cited by 30
Self-citation
Metadata
- Authors
- Wong, A., Amato, M. G., Seger, D. L., Slight, S. P., Beeler, P. E., Dykes, P. C., Fiskio, J. M., Silvers, E. R., Orav, E. J., Eguale, T., & Bates, D. W.
- Venue
- Journal of Critical Care
- Publisher
- Elsevier BV
- Published
- 2017-06
- Volume
- 39
- Pages
- 156-161
- ISSN
- 0883-9441 (ISSN-L)
- OpenAlex
- W2589497695
- Cited by
- 41
- References
- 13
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.