The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Femtosecond laser capsulotomy
Abstract
PURPOSE: To evaluate a femtosecond laser system to create the capsulotomy. SETTING: Porcine and cadaver eye studies were performed at OptiMedica Corp., Santa Clara, California, USA; the human trial was performed at the Centro Laser, Santo Domingo, Dominican Republic. DESIGN: Experimental and clinical study. METHODS: Capsulotomies performed by an optical coherence tomography-guided femtosecond laser were evaluated in porcine and human cadaver eyes. Subsequently, the procedure was performed in 39 patients as part of a prospective randomized study of femtosecond laser-assisted cataract surgery. The accuracy of the capsulotomy size, shape, and centration were quantified and capsulotomy strength was assessed in the porcine eyes. RESULTS: Laser-created capsulotomies were significantly more precise in size and shape than manually created capsulorhexes. In the patient eyes, the deviation from the intended diameter of the resected capsule disk was 29 μm ± 26 (SD) for the laser technique and 337 ± 258 μm for the manual technique. The mean deviation from circularity was 6% and 20%, respectively. The center of the laser capsulotomies was within 77 ± 47 μm of the intended position. All capsulotomies were complete, with no radial nicks or tears. The strength of laser capsulotomies (porcine subgroup) decreased with increasing pulse energy: 152 ± 21 mN for 3 μJ, 121 ± 16 mN for 6 μJ, and 113 ± 23 mN for 10 μJ. The strength of the manual capsulorhexes was 65 ± 21 mN. CONCLUSION: The femtosecond laser produced capsulotomies that were more precise, accurate, reproducible, and stronger than those created with the conventional manual technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Lens Opacities Classification System III
Chylack, L. T. (1993) · Archives of Ophthalmology · doi:10.1001/archopht.1993.01090060119035 · Cited by 2,913
Ambulatory surgery in the United States: development and prospects
Burns, L. A., & Ferber, M. S. (1981) · Journal of Ambulatory Care Management · doi:10.1097/00004479-198108000-00003 · Cited by 852
Sources of error in intraocular lens power calculation
Norrby, S. (2008) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2007.10.031 · Cited by 708
Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery
Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20091117-04 · Cited by 563
Femtosecond Laser–Assisted Cataract Surgery with Integrated Optical Coherence Tomography
Palanker, D. V., Blumenkranz, M. S., Andersen, D., Wiltberger, M., Marcellino, G., Gooding, P., Angeley, D., Schuele, G., Woodley, B., Simoneau, M., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001305 · Cited by 277
Self-citation
Cited by
Carbon footprint and cost–effectiveness of cataract surgery
Venkatesh, R., van Landingham, S. W., Khodifad, A. M., Haripriya, A., Thiel, C. L., Ramulu, P., & Robin, A. L. (2016) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000228 · Cited by 76
Metadata
- Authors
- Friedman, N. J., Palanker, D. V., Schuele, G., Andersen, D., Marcellino, G., Seibel, B. S., Batlle, J., Feliz, R., Talamo, J. H., Blumenkranz, M. S., & Culbertson, W. W.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2011-07
- Volume
- 37
- Issue
- 7
- Pages
- 1189-1198
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2136994507
- Cited by
- 373
- References
- 5
- FWCI
- 32.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Femtosecond laser capsulotomy. https://app.cochat.ai/papers/10.1016/j.jcrs.2011.04.022
- The paper
- Friedman, N. J., Palanker, D. V., Schuele, G., Andersen, D., Marcellino, G., Seibel, B. S., Batlle, J., Feliz, R., Talamo, J. H., Blumenkranz, M. S., & Culbertson, W. W. (2011). Femtosecond laser capsulotomy. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2011.04.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.