CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: This review compared Computer-aided designand Computer-aided manufactured (CAD-CAM) and conventionally constructed removable complete dentures (CDs). DATA: Seventy-three studies reporting on CAD-CAM (milled/3D-printed) CDs were included in this review. The most recent literature search was performed on 15/03/2021. SOURCES: Two investigators searched electronic databases [PubMed (MEDLINE), Embase, CENTRAL], online search engines (Google) and research portals. Hand searches were performed to identify literature not available online. STUDY SELECTION: Studies on CAD-CAM CDs were included if they reported on trueness of fit, biocompatibility, mechanical, surface, chemical, color , microbiological properties, time-cost analysis, and clinical outcomes. Inter-investigator reliability was assessed using kappa scores. Meta-analyses were performed on the extracted data . RESULTS: The kappa score ranged between 0.897-1.000. Meta-analyses revealed that 3D-printed CDs were more true than conventional CDs (p = 0.039). Milled CDs had a higher flexural-strength than conventional and 3D-printed CDs (p < 0.0001). Milled CDs had a higher flexural-modulus than 3D-printed CDs (p < 0.0001). Milled CDs had a higher yield-strength than injection-molded (p = 0.004), and 3D-printed CDs (p = 0.001). Milled CDs had superior toughness (p < 0.0001) and surface roughness characteristics (p < 0.0001) than other CDs . Rapidly-prototyped CDs displayed poor color-stability compared to other CDs (p = 0.029). CAD-CAM CDs d displayed better retention than conventional CDs (p = 0.015). Conventional CDs had a higher strain at yield point than milled CDs (p < 0.0001), and had superior esthetics than 3D-printed (p < 0.0001). Fabrication of CAD-CAM CDs required less chairside time (p = 0.037) and lower overall costs (p < 0.0001) than conventional CDs. CONCLUSIONS: This systematic review concludes that CAD-CAM CDs offer a number of improved mechanical/surface properties and are not inferior when compared to conventional CDs. CLINICAL SIGNIFICANCE: CAD-CAM CDs should be considered for completely edentulous patients whenever possible, since this technique offers numerous advantages including better retention, mechanical and surface properties but most importantly preserves a digital record. This can be a great advantage for older adults with limited access to dental care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552 · cited 1×
“Random-effects or fixed-effects models were used to calculate the weighted means across the studies [12] and I-squared statistics (I2-statistics) was used to assess the heterogeneity Table 9 (continued )”
MethodA review of assessing the accuracy of classifications of remotely sensed data
Congalton, R. G. (1991) · Remote Sensing of Environment · doi:10.1016/0034-4257(91)90048-b · Cited by 7,724 · cited 1×
“The clinical retention of a CD depends, apart from the morphology and resilience of the denture bearing tissues, on adaptation of the intaglio surface to the tissues, border seal, and salivary flow-related effects associated with viscosity and film thickness of the oral fluid [86,87].”
BackgroundFunnel plots for detecting bias in meta-analysis
Sterne, J. A. C., & Egger, M. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00377-8 · Cited by 3,779 · cited 1×
“Risk of publication bias was assessed across the studies using funnel plots [13].”
MethodThe future of dental devices is digital
van Noort, R. (2012) · Dental Materials · doi:10.1016/j.dental.2011.10.014 · Cited by 1,408
Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques
Goodacre, B. J., Goodacre, C. J., Baba, N. Z., & Kattadiyil, M. T. (2016) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.02.017 · Cited by 331 · cited 2×
“(2016) [49] Compression molding Lucitone 199 Denture Base Resin, Dentsply Sirona 0.”
BackgroundKattadiyil, M. T., Jekki, R., Goodacre, C. J., & Baba, N. Z. (2015) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.08.001 · Cited by 272 · cited 2×
“(2015) [23] Compressionmolding Lucitone 199, Dentsply Intl NS N/A 15 Predoctoral dental students delivered two sets of dentures, compression molding and milled dentures, for each patient.”
MethodKalberer, N., Mehl, A., Schimmel, M., Müller, F., & Srinivasan, M. (2019) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2018.09.001 · Cited by 265 · cited 1×
“(2019) [39] Milled AvaDent Digital Dental Solutions 0.”
BackgroundSelf-citation
Metadata
- Authors
- Srinivasan, M., Kamnoedboon, P., McKenna, G., Angst, L., Schimmel, M., Özcan, M., & Müller, F.
- Venue
- Journal of Dentistry
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 113
- Pages
- 103777
- ISSN
- 0300-5712 (ISSN-L)
- OpenAlex
- W3194106948
- Cited by
- 205
- References
- 36
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes. https://app.cochat.ai/papers/10.1016/j.jdent.2021.103777
- The paper
- Srinivasan, M., Kamnoedboon, P., McKenna, G., Angst, L., Schimmel, M., Özcan, M., & Müller, F. (2021). CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes. Journal of Dentistry. https://doi.org/10.1016/j.jdent.2021.103777
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.