Cited by 21Membrane-based Ion Separation TechniquesMembrane Separation TechnologiesFreezing and Crystallization Processes

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Pilot-scale capacitive deionization for water softening: Performance, energy consumption, and ion selectivity

Open access
Yoon, Hongsik, Jeon, SeongBeom, Min, Taijin, Lee, Chung Kyu, Lee, Gunhee·2024·Journal of Environmental Chemical Engineering

Abstract

Capacitive deionization (CDI) has emerged as an efficient process for hardness control than traditional water-softening technologies. However, few systematic studies have been conducted on water softening using pilot-scale CDI systems. For industrial applications, it is essential to investigate deionization performance, energy consumption, and selectivity for divalent cations through pilot-scale studies. In this study, we examined the deionization performance and energy consumption of a pilot-scale CDI process for effective water softening. The key operational variables analyzed were the applied voltage (200–300 V (i.e., 1.0–1.5 V per pair)), feed concentration (550–1250 mg/L), recovery ratio (50–80 %), flow rate (3–5 L/min), and adsorption/desorption time (80–180 s). Within this range, a high voltage, low feed concentration, low recovery ratio, high flow rate, and long adsorption/desorption times are advantageous for the total dissolved solids (TDS) removal ratio. In terms of energy efficiency, expressed as TDS removal per unit energy consumption, a low voltage, low feed concentration, low recovery ratio, fast flow rate, and long adsorption/desorption time are beneficial. Additionally, we investigated the selective removal of Ca 2+ over Na + under various operating conditions, as well as its impact on enhancing energy efficiency. The pilot CDI system achieved a Ca/Na selectivity coefficient of approximately 2.4 and it was analyzed to achieve up to 45 % energy-saving efficien…

Overview

Integrity signals

Registry

Crossref · 10.1016/j.jece.2024.114259

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 39 references

Research works printed but not linked: 2

  1. Jiang, 2023, A critical review on the electrochemical water softening technology from fundamental research to practical application, Water Res.
  2. H.J. Van Dijk, J.Q. Verberk, P.J. De Moel, Drinking water: principles and practices, World Scientific, 2006.

Cited by

Sorted by citations

See all 21

Metadata

Authors
Yoon, H., Jeon, S., Min, T., Lee, C. K., & Lee, G.
Affiliations
Korea Institute of Machinery & Materials (KR)
Corresponding author
Yoon, Hongsik
Venue
Journal of Environmental Chemical Engineering
Publisher
Elsevier BV
Published
2024-12
Volume
12
Issue
6
Pages
114259
ISSN
  • 2213-2929 (ISSN-L)
  • 2213-3437
OpenAlex
W4402898744
Cited by
19
References
39
Citations by year
2026: 11 · 2025: 7 · 2024: 1
FWCI
2.09
Type
journal article
Language
en
Open access
Locations
Journal of environmental chemical engineering (publishedVersion, cc-by-nc-nd)
Funders
  • Korea Institute of Machinery and Materials (KN031E)
  • Korea Institute of Energy Technology Evaluation and Planning
  • Ministry of Trade, Industry and Energy (20213030040590, 20223030040060)
Topics
  • Physical Sciences › Chemical Engineering › Filtration and Separation › Membrane-based Ion Separation Techniques
  • Physical Sciences › Environmental Science › Water Science and Technology › Membrane Separation Technologies
  • Physical Sciences › Chemical Engineering › Filtration and Separation › Freezing and Crystallization Processes
Keywords
capacitive deionization, water softening, divalent cation selectivity, energy efficiency, total dissolved solids removal, operating conditions optimization, recovery ratio

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review