Unnecessary arrhythmia monitoring and underutilization of ischemia and QT interval monitoring in current clinical practice: baseline results of the Practical Use of the Latest Standards for Electrocardiography trial
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Purpose To examine the appropriate use of arrhythmia, ischemia, and QTc interval monitoring in the acute care setting. Methods We analyzed baseline data of the PULSE Trial, a multi-site randomized clinical trial evaluating the effect of implementing ECG monitoring practice standards. Research nurses reviewed medical records for indications for monitoring and observed if arrhythmia, ischemia, and QT interval monitoring were being done on 1,816 patients in 17 hospitals. Results Almost all (99%) patients with an indication for arrhythmia monitoring were being monitored, but 85% of patients with no indication were monitored. Of patients with an indication for ischemia monitoring, 35% were being monitored, but 26% with no indication were being monitored for ST-segment changes. Only 21% of patients with an indication for QT interval monitoring had a QTc documented, but 18% of patients with no indication had a QTc documented. Conclusion Our data show evidence of inappropriate monitoring: under-monitoring for ischemia and QTc prolongation and over-monitoring for all 3 types of monitoring, especially arrhythmia monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drew, B. J., Ackerman, M. J., Funk, M., Gibler, W. B., Kligfield, P., Menon, V., Philippides, G. J., Roden, D. M., & Zareba, W. (2010) · Circulation · doi:10.1161/circulationaha.109.192704 · Cited by 821
Self-citationDrew, B. J., Califf, R. M., Funk, M., Kaufman, E. S., Krucoff, M. W., Laks, M. M., Macfarlane, P. W., Sommargren, C., Swiryn, S., & Van Hare, G. F. (2004) · Circulation · doi:10.1161/01.cir.0000145144.56673.59 · Cited by 609
Self-citationRole of telemetry monitoring in the non-intensive care unit
Estrada, C. A., Rosman, H. S., Prasad, N. K., Battilana, G., Alexander, M., Held, A. C., & Young, M. J. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80270-7 · Cited by 90
Drew, B., & Krucoff, M. (1999) · American Journal of Critical Care · doi:10.4037/ajcc1999.8.6.372 · Cited by 87
Self-citation
Cited by
Sandau, K. E., Funk, M., Auerbach, A., Barsness, G. W., Blum, K., Cvach, M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 342
Self-citationAlarm fatigue: impacts on patient safety
Ruskin, K. J., & Hueske-Kraus, D. (2015) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000260 · Cited by 226
“implemented an altered set of alarm parameters in which a run of ventricular tachycardia less than five beats and ST segment changes generated inaudible visual messages, although the peripheral oxygen saturation was changed to audible alarm at 88% instead of 89% [25].”
BackgroundAlarm Fatigue: Use of an Evidence-Based Alarm Management Strategy
Turmell, J. W., Coke, L., Catinella, R., Hosford, T., & Majeski, A. (2017) · Journal of Nursing Care Quality · doi:10.1097/ncq.0000000000000223 · Cited by 59
Pettersen, T. R., Fålun, N., & Norekvål, T. M. (2014) · European Journal of Cardiovascular Nursing · doi:10.1177/1474515113515585 · Cited by 17
Metadata
- Authors
- Funk, M., Winkler, C. G., May, J. L., Stephens, K., Fennie, K. P., Rose, L. L., Turkman, Y. E., & Drew, B. J.
- Venue
- Journal of Electrocardiology
- Publisher
- Elsevier BV
- Published
- 2010-11
- Volume
- 43
- Issue
- 6
- Pages
- 542-547
- ISSN
- 0022-0736 (ISSN-L)
- OpenAlex
- W2132430922
- Cited by
- 49
- References
- 4
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unnecessary arrhythmia monitoring and underutilization of ischemia and QT interval monitoring in current clinical practice: baseline results of the Practical Use of the Latest Standards for Electrocardiography trial. https://app.cochat.ai/papers/10.1016/j.jelectrocard.2010.07.018
- The paper
- Funk, M., Winkler, C. G., May, J. L., Stephens, K., Fennie, K. P., Rose, L. L., Turkman, Y. E., & Drew, B. J. (2010). Unnecessary arrhythmia monitoring and underutilization of ischemia and QT interval monitoring in current clinical practice: baseline results of the Practical Use of the Latest Standards for Electrocardiography trial. Journal of Electrocardiology. https://doi.org/10.1016/j.jelectrocard.2010.07.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.