Alarm Fatigue: Use of an Evidence-Based Alarm Management Strategy

Turmell, Jacob W., Coke, Lola, Catinella, Rachel, Hosford, Tracy, Majeski, Amy·2017·Journal of Nursing Care Quality

Abstract

The purpose of this article is to describe the impact of an evidence-based alarm management strategy on patient safety. An alarm management program reduced alarms up to 30%. Evaluation of patients on continuous cardiac monitoring showed a 3.5% decrease in census. This alarm management strategy has the potential to save $136 500 and 841 hours of registered nurses' time per year. No patient harm occurred during the 2-year project.

Integrity signals

Registry

Crossref · 10.1097/ncq.0000000000000223

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Reduction of alarms due to alarm management strategies ranges from 24% to 88.5% per ICU, indicating effectiveness of such strategies, including staff training for any ward that uses patient monitoring devices.

    “Notably, the reduction of alarms due to alarm management strategies ranges from 24% to 88.5% per ICU, indicating the effectiveness of such strategies, including staff training for any ward that uses patient monitoring devices [32-34].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Turmell, J. W., Coke, L., Catinella, R., Hosford, T., & Majeski, A.
Affiliations
Spectrum Health (US)
Corresponding author
Turmell, Jacob W.
Venue
Journal of Nursing Care Quality
Published
2017-01
Volume
32
Issue
1
Pages
47-54
ISSN
1057-3631 (ISSN-L)
OpenAlex
W2512925537
Cited by
59
References
9
Citations by year
2026: 6 · 2025: 8 · 2024: 8 · 2023: 9 · 2022: 3 · 2021: 10 · 2020: 3 · 2019: 3 · 2018: 8 · 2017: 1
FWCI
4.43
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Nursing Care Quality (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
  • Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
  • Health Sciences › Medicine › Emergency Medicine › Hospital Admissions and Outcomes
Keywords
alarm fatigue, alarm management, patient safety, continuous cardiac monitoring, nursing workload, cost reduction, evidence-based practice
MeSH terms
Attitude of Health Personnel, Auditory Fatigue, Humans, Monitoring, Physiologic, Program Evaluation, Evidence-Based Nursing, Clinical Alarms, Patient Safety

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review